54
ASSA ABLOY Hospitality
66 8003 016-3
Appendix C: To set up a suite
Introduction
If two or more rooms should form a suite, all concerned thermostats must be connected as a
suite and the thermostat in the
master room
(main room of the suite) or
master rooms
(if there
are more than two rooms in the suite) must be initialized with suite settings. Follow the steps in
chapter 5
to set up the online network, but
do not initialize the thermostat with suite settings at that point
. There are three suite
configurations:
One foyer door leading to two rooms, each with one guest door; see details
here
Connected doors: two rooms connected by internal mechanical doors, no foyer door in
front of the two guest doors; see details
here
One guest door leading to a suite of rooms (two or more rooms); see details
here
To set up a suite with foyer door
One possible suite configuration is to have a foyer door, and behind the foyer door two rooms which form
a suite. In the example shown in Figure C1, the suite contains the rooms 102 and 103; each room has
one thermostat and one motion sensor. Room 102 is the master room of the suite, and hence the foyer
lock 102-103 is connected to the thermostat in room 102 when the online network is set up.
Note:
For more information about the suite functionality, click
here
.
Note:
The foyer door must be
online; this is however not set up in the
Door details
dialog, instead the online type 'ZigBee' is
automatically sent to the server with the first event from the door.
Note:
Only one of the thermostats,
the master thermostat, is initialized with suite settings. The link between the two thermostats is set up
in Orion Service.
Figure C1