13
530 DX SERIES
DIGITAL ENTRANCE SET
2. Install digital lock and interior furniture plate.
(a) Fit rubber seal to the back of the digital lock and
interior furniture plate.
(b) Insert blade end of spindle in vertical position into
digital lock drive gear.
(c) Install digital lock and interior furniture plate to door
with both turn knobs in vertical position.
NOTE: Ensure that spindle engages latch hub and
interior furniture plate drive gear.
(d) Secure using two metal thread mounting screws.
10000-221_30621-0504
Latch
hub
Door
Latch
Latch mounting screws
Interior furniture
plate
Metal thread
mounting screws
Seal
Seal
Spindle
Digital lock
Latch mounting screws
Door
Latch
Seal
Seal
Door
Interior furniture
plate drive gear
lock drive gear
Blade end
of spindle
Metal thread
mounting screws
530 DX SERIES
DIGITAL ENTRANCE SET
Strike
Jamb
Half door thickness
Latch mounting screws
3. Prepare jamb and install strike.
(a) Mark strike location on jamb edge directly opposite
latch as shown.
(b) Locate strike on jamb edge centrally about
horizontal centreline with screw holes in strike on
vertical centreline. Mark outline of strike and bolt
hole onto jamb edge.
(c) Mortice in the following sequence:
1. Bolt hole mortice 16mm ( ") deep.
2. Strike mortice 1.5mm ( ") deep.
(d) Pre-drill 2.5mm ( ") to accept mounting screws
and secure using woodscrews supplied.
5
8
1
16
3
32
3
PREPARE AND INSTALL
2
INSTALL LOCK
1
1. Prepare door and install latch.
(a) Mark and drill holes as shown on template.
(b) Insert latch into hole in door edge and scribe around faceplate.
(c) Mortice 4mm ( ") deep to accept latch faceplate.
(d) Pre-drill 2.5mm ( ") to accept mounting screws and secure
latch using woodscrews supplied.
5
32
3
32
Lock mounting position.
This product is more convenient to operate at approximately
chest level, but door construction may restrict the mounting position.
SOLID DOORS:
Permit mounting at any height.
HOLLOW CORE DOORS:
Mounting may be restricted by the
size and position of the timber block within the door for lock mounting.
Note: For fire door applications, keypad must be fitted
without rubber mounting pad.
FOLLOW INSTRUCTIONS CAREFULLY
INSTALL LOCK
LOCK MOUNTING POSITION