The KESO KEK i-turn thumbturn is an electronic cylinder. It is intended for indoor use 
only in locations where stricter control and safety requirements need to be met. The 
KESO KEK i-turn thumbturn can be easily and quickly installed into existing doors 

without any wiring. It can be adapted perfectly to structural conditions and fulfils high 
architectural standards. k-entry

TM

, authorisations can be managed centrally in combination with 

the KESO management software. 
Like all KESO KEK products, the KESO KEK i-turn thumbturn is NOK (network on key) 
compatible.  
 
 

3

 

Application site 

For

 

indoor use

 

only

The threshold values as specified in the technical data must be observed (see Item 13). 
 
 

4

 

Ordering information 

 

Photo 

Item No. 

Designation/Description 

 

21.43V.060.00.00.KT 

KESO KEK i-turn thumbturn double 
cylinder 
 
Standard length: 30/30 mm 
 
Extension: 
both sides, in 5 mm increments; 
maximum 80/80 mm 

 

21.43W.060.00.00.KT 

KESO KEK i-turn thumbturn single 
cylinder 
 
Standard length: 30/10 mm 
 
Extension: 
one side, in 5 mm increments; 
maximum 80/10 mm 

 
 

4.1

 

Scope of delivery 

1 unit 

KESO KEK i-turn thumbturn cylinder with standard actuator  

1 unit 

65 mm fixing screw 

1 unit  

Battery 

1 unit  

Screw set 

1 unit  

Assembly instructions 

1 unit  

Tool for replacing the batteries 

 

Содержание KESO KEK i-turn

Страница 1: ...rawing 5 6 Requirements 6 7 Operation 6 8 Programming with KESO k entryTM 6 9 Alarm and status signals 8 10 Installation 9 11 Replacing the batteries 10 12 Emergency power emergency opening 11 13 Technical data 12 14 Accessories and individual parts 13 15 Appendix 14 16 Service support 15 17 Notes 16 Date of issue 29 10 2010 Version 009 ASSA ABLOY the global leader in door opening solutions ...

Страница 2: ...y to our assembly instructions and without our prior consent 1 1 1 Disposal All articles listed in this documentation must not be disposed of as normal household waste It is the consumer s responsibility to dispose of the product at a recycling collection point for electrical and electronic waste Disposing of this waste separately helps to optimise reprocessing of all materials suitable for recycl...

Страница 3: ...KESO KEK products the KESO KEK i turn thumbturn is NOK network on key compatible 3 Application site For indoor use only The threshold values as specified in the technical data must be observed see Item 13 4 Ordering information Photo Item No Designation Description 21 43V 060 00 00 KT KESO KEK i turn thumbturn double cylinder Standard length 30 30 mm Extension both sides in 5 mm increments maximum...

Страница 4: ...KEK i turn thumbturn double knob cylinder in EU profile Article No 21 43V Euro profile cylinders Diameter ø17 mm with valve cut out 5 2 KESO KEK i turn thumbturn single cylinder in EU profile Article No 21 43W Euro profile cylinders Diameter ø17 mm with valve cut out Outside Inside 50 5 36 5 50 5 36 5 ...

Страница 5: ...eries Inserting the batteries incorrectly can damage or even destroy electronic components KESO does not recommend using rechargeable batteries as they do not have sufficient capacity to match the power requirements As old batteries can leak it is advisable to check the battery status at regular intervals KESO AG is not liable for consequential damage caused by defective batteries We do not offer ...

Страница 6: ... entryTM Management Software 1 Release time Once access has been enabled the outside knob remains engaged for the pre set time You can set a time interval of between 0 5 and 25 5 seconds 2 Optical signal active Indicates authorisation and battery status on the outside door knob 3 Optical signal indicating end of battery life active Low battery status is indicated by a multistage alarm signal optic...

Страница 7: ... Access denied Default setting If access is denied the red LED flashes 9 3 Low battery status Low battery status is indicated by a multistage alarm signal optical KESO recommends checking the battery power status at least once a year using the KESO KEK Programmer PPG V2 or a multimeter 9 3 1 Pre alarm threshold If the battery level drops below the pre warning threshold the green and red LEDs flash...

Страница 8: ...ore installing If you have any queries regarding installation please contact your dealer 10 1 Individual parts of double door knob Pos Uni ts Description Item No 1 1 Cylinder body with assembled outside door knob 1 1 Outside door knob mechanism E 072 2 1 Inside door knob mechanism E 071 3 1 Lithium battery type CR2 K 533 4 1 65 mm fixing screw G 100 65 5 1 Assembly tool K 554 10 2 Cylinder assembl...

Страница 9: ...KESO KEK i turn KESO AG 10 2010 Subject to change Page 10 of 18 Pages 11 Replacing the batteries B 1 B 3 B 2 B 4 1 2 3 Remove cover 3 Replace cover ...

Страница 10: ...the KAPI programming cable into the KESO KEK i turn thumbturn interface 2 Connect the KAPI programming cable to the KESO KEK Programmer PPG V2 3 Hold insert an authorised KEK identification medium into onto the KESO KEK Programmer PPG V2 4 Start the KESO KEK Programmer PPG V2 and click on the menu item Emergency opening Emergency opening is now complete The thumbturn is engaged and can now be open...

Страница 11: ...to 50 C Humidity 15 to 70 non condensed Time slots 24 each divided into 8 time intervals Special days 3 e g works holidays holidays public holidays Event logging 500 events FIFO with date time door designation person operation User keys 8 000 per electronic system Programming interfaces KAPI cable in connection with the KESO KEK Programmer PPG V2 Certification CE Application type interior stand al...

Страница 12: ...no E 066 92 Packing unit 10 units per pack 14 4 Battery Article no K 533 Packing unit one unit Brand Energizer Type lithium type CR2 Voltage per battery 3 0 Volt 14 4 1 Batteries The battery should be replaced by a new one after 40 000 actuations or after two years at the latest Carbon zinc batteries or rechargeable batteries have less power which can lead to malfunctions 14 5 Assembly tool Articl...

Страница 13: ...not be guaranteed if you fail to update the firmware version The latest firmware can be downloaded from www keso com To clean KESO products and accessories wipe with a damp or anti static cloth Never use aggressive cleaning agents or clean with silicon oil as this can cause malfunctions Only use cleaning agents that contain no corrosive substances Never repair or modify KESO products or accessorie...

Страница 14: ...ons you may have regarding your KESO product Personal KESO consultation training We provide a personal consultation and training service for technical matters regarding products We would be happy to make you an offer Please take a look at the program of open courses which we offer Personal KESO support Should a fault occur or you have a problem which you are unable to solve with the help of the su...

Страница 15: ... I 40017 San Giovanni in Persiceto CH 1028 Préverenges Telefon 49 4181 924 0 Telefon 41 21 811 29 29 Telefon 39 51 681 25 59 Telefax 49 4181 924 100 Telefax 41 21 811 29 00 Telefax 39 51 681 24 01 E Mail info keso de E Mail keso sa keso com E Mail info keso it Internet www keso de Internet www keso com Internet www keso it ASSA ABLOY is the global leader in door opening solutions dedicated to sati...

Отзывы: