***CAUTION*** 

The Installer must ensure the lock can be opened before closing the cabinet. 

 
12. INSTALL the single-door strike plate. 
 

12a.  PLACE the strike plate over the pilot holes, and INSERT and TIGHTEN the two screws in the slotted holes. 

 

12b.  CLOSE the door to verify installation, and ADJUST the strike plate if necessary. 
 
12d.  INSERT and TIGHTEN the lock down screw on the strike plate.  

 

 
 
 

OPTIONAL DOUBLE-DOOR INSTALLATION 

13. INSTALL the Double-Door Strike Plate Mounting Bracket 

 

NOTE

: The double-door bracket requires that one door can be secured. 

 

13a.  PLACE the bracket on door, making sure it aligns with the mark made in Step 2c and the edge of the door.  

 

13b.  MARK the door.  

 

13c.  REMOVE the bracket and DRILL pilot holes at the two marks. 

 

13d.  INSTALL the bracket using the mounting screws provided. 

 
 
 
 
 
 

 

14. INSTALL the double-door strike plate. 

 

14a.  PLACE the strike plate over the holes on the bracket.  

 

14b.  INSERT and TIGHTEN the three 6-32 X 5/16”screws 

provided. 

 

 

13a   

13b and 13c  

 

12a–c

 

 

 

12d 

 

 

3080076.004, Rev. B 

 

                    11 

 

 

Содержание K100-622

Страница 1: ...ithium AA Cell 1 5 Volts V Energizer L91 Ultimate Lithium Battery Life 50 000 cycles Operating Temperature 32 F to 122 F 0 C to 50 C FCC Part 15 Compliant IC Compliant Credentials Supported PA Low Frequency model HID PROX EM PROX SE High Frequency model iCLASS iCLASS SEOS iCLASS SE ISO14443B UID Mifare Mifare Plus Desfire SE Desfire EV1 NFC Product Specifications For technical support please call ...

Страница 2: ...b connects to the access control system with Wiegand wiring typical of a Wiegand Reader When a credential card is presented to the reader on the lock the request for access is sent wirelessly to the communication hub The communication hub then communicates through Wiegand wiring to the access control system where the decision is made to grant or deny access Installation Process Testing the Lock Co...

Страница 3: ...le radio link it is recommended that the hub is located within fifty 50 feet of the lock A maximum of two interior walls between the hub and lock is recommended Recommended locations A Wall Mount B Ceiling Mount C Wall Mount Adjacent Room NOTE The hub is not rated for use in plenum air spaces Mounting the Hub NOTE The following applies primarily to the K100 622H Model with included hub The include...

Страница 4: ...e Green LED signal is not available to indicate approved access the approval input can be activated by a relay with NO attached to Green LED and C to GND NOTE 2 The Red LED input is used to indicate access denied If the RED LED signal is not connected the lock will flash RED three times when a non approved card is presented indicating loss of connection to the hub rather than access denied Any oth...

Страница 5: ...the wire the wire is keyed from the reader to the socket in the lock battery compartment 4 INSTALL the batteries and ENSURE correct orientation the lock will self test and beep once 5 PRESENT a credential known to the access control system 6 IF a green LED indicating access is granted is lit THEN TWIST the knob to retract the latch 7 REFER to the LED reference card for any other c0des 8 REMOVE the...

Страница 6: ...ally where you would like it to mount 1b LOCATE the lock centerline notch on the latch and MARK this point on the inside of the cabinet door using a pencil 1c DRAW the horizontal latch centerline from this mark on the inside of the cabinet door and TRANSFER it to the outside of the cabinet door 1d TRANSFER this centerline to the inside of the cabinet or the second door on a double door cabinet 1e ...

Страница 7: ...ate the Strike Plate Template 3b PEEL OFF the protective layer of the Lock Template ALIGN it to both the latch centerline and the line depicting the inside wall of cabinet and PRESS to secure NOTE Two of the holes in the following step are 3 16 diameter and two are 1 2 diameter The two pilot holes are 1 16 3c DRILL four holes and two pilot holes through the cabinet as shown in the figure below 3d ...

Страница 8: ...rientation allows for installation THEN INSTALL the Key Override Paddle 5a INSERT the Paddle s arm into the opening shown and ALIGN the rails of the paddle to the ones on the lock 5b SLIDE the paddle gently until it stops 6 PREPARE the Key Override Door NOTE The Cam Lock is optional and must be obtained by others 6a IF a Key Override is used THEN USE template to mark and drill a hole for a 3 4 Cam...

Страница 9: ...STALL the lock 8a REMOVE the battery cover from lock 8b PLACE the lock on the inside of the door threading the cable through the lock 8b ATTACH the lock to the antenna reader using two 8 32 lock mount screws see Table 2 for length and TIGHTEN the screws 8c INSTALL the two 6 self threading screws and TIGHTEN NOTE The third 6 self threading screw is important to achieve maximum holding force for doo...

Страница 10: ...OTE New batteries should always be used and inserted in the correct polarity position 10a INSTALL the battery and battery cover 10b INSTALL and TIGHTEN the screws 11 PLACE the single door Strike Plate Template 11a PEEL OFF the protective layer of the Strike Plate Template and ALIGN it to both the latch centerline and the edge of cabinet 11b DRILL two pilot holes as shown on template 11c REMOVE the...

Страница 11: ...E DOOR INSTALLATION 13 INSTALL the Double Door Strike Plate Mounting Bracket NOTE The double door bracket requires that one door can be secured 13a PLACE the bracket on door making sure it aligns with the mark made in Step 2c and the edge of the door 13b MARK the door 13c REMOVE the bracket and DRILL pilot holes at the two marks 13d INSTALL the bracket using the mounting screws provided 14 INSTALL...

Страница 12: ...ormes FCC Cet équipement a été testé et trouvé conforme aux limites pour un dispositif numérique de classe B conformément à la Partie 15 des règlements de la FCC Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle Cet équipement génère utilise et peut émettre des fréquences radio et s il n est pas installé et utili...

Отзывы: