55
EN
Technical data
Electrical data
Feature
Operating voltage
(controlled direct-current (DC)
voltage)
12 V . . . 24 V tolerance –15 % / +15 %
Supply voltage
10.1 V
12.0 V
24.0 V
28.0 V
Current consumption (locked)
360 mA
360 mA
190 mA
160 mA
Max. current consumption
for max. 2 s
620 mA
600 mA
290 mA
250 mA
Power consumption (locked)
4 W
4.5 W
5 W
4.5 W
Power consumption, maximum
6.5 W
7.5 W
7 W
7 W
Max. Max. contact loading
capacity for armature contact
25 V / 500 mA
Max. Contact rating of the door
contact
25 V / 100 mA
Fail-unlocked operating
principle
Yes