SE LP10 ML20600 Mortise Lock
5
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
4) Specifications / Features
McKinney
Electric
Hinge
SE LP10
Wiegand Access
Control System
The reader requires 12VDC for power, while the lock
accepts either 12 or 24VDC.
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 12VDC
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
100
20
18
16
14
14
12
12
10
150
18
16
14
12
12
12
10
—
200
16
14
12
12
10
10
—
—
250
16
14
12
10
10
10
—
—
300
16
12
12
10
10
—
—
—
400
14
12
10
—
—
—
—
—
500
14
10
10
—
—
—
—
—
750
12
10
—
—
—
—
—
—
1,000
10
—
—
—
—
—
—
—
1,500
10
—
—
—
—
—
—
—
Wire Gauge Chart 12VDC
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 24VDC
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
100
24
20
18
18
16
16
14
12
150
22
18
16
16
14
14
12
10
200
20
18
16
14
14
12
12
10
250
18
16
14
14
12
12
12
10
300
18
16
14
12
12
12
10
—
400
18
14
12
12
10
10
—
—
500
16
14
12
10
10
—
—
—
750
14
12
10
10
—
—
—
—
1,000
14
10
10
—
—
—
—
—
1,500
12
10
—
—
—
—
—
—
Wire Gauge Chart 24VDC
Electrical Specifications
12/24VDC System
12V
24V
Average
Peak
Average
Peak
Reader
100mA
220mA
n/a
n/a
Actuator
15mA
500mA
15mA
500mA
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical
Code (CEC), Part I, Safety Standard for Electrical Installations, local codes and the authorities having jurisdiction.
This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70.
• UL 294 Access Control Ratings
:
Destructive Attack
Level 1
Line Security
Level 1
Endurance
Level 4
Standby Power
Level 1
• UL Listed* - UL 294 Indoor Use
• CUL Listed - S319: Class 1
• ANSI/BHMA A156.25 Listed
Grade 1 Compliant
UL testing was conducted on product powered by
UL Listed model 9001GR/AC injector; manufactured
by Microsemi Corp.
*UL294, S319, & BHMA A156.25 currently not applicable