1-800-543-3658 • [email protected]
From Outside: When door is opened by turning operator latch, top latch and bottom bolt should
retract and stay retracted until plunger screw is pushed in.
From Inside: When door is opened by depressing crossbar, top latch and bottom bolts should retract,
and stay retracted until plunger screw is pushed in.
Lock crossbar in dogged down position. Latch and bolt should be fully retracted.
NOTE: No dogging feature on “U” series.
13
Test Operation
When door is closed against top strike,
plunger screw releases top latch and
bottom bolt. Adjust so that when door is
shut tight, screw head just touches strike.
(Figure 20)
12
Adjust Plunger Screw
Just Touch
Figure 20