background image

Installation Instructions

Copyright © 2018, 2020,  ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or 
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

FM466  04/20

For installation assistance contact Corbin Russwin

1-800-543-3658 • [email protected]

 WARNING

This product can expose you to lead 
which is known to the state of California 
to cause cancer and birth defects or other 
reproductive harm. For more information 
go to www.P65warnings.ca.gov.

ED7800 Series

Concealed Vertical Rod

Exit Devices

Содержание Corbin Russwin ED7800 Series

Страница 1: ...nd Egress Hardware Group Inc is prohibited FM466 04 20 For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com WARNING This product can expose you to...

Страница 2: ...e Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com TOC Table of Contents 1 Components 3 2 Pre Installation 4 3 Prepare...

Страница 3: ...ke Mounting Bracket Bottom Bolt Tension Spring Bottom Bolt Operating Tube Screw Tenon Dogging Key Felt Deadener Dogging Hole Cotter Pin Hole Lifting Flange for Active Case Active Case Outside Operator...

Страница 4: ...over A Lift Figure 3 3 Prepare Door and Frame If not already fully prepared follow template furnished and drawings shown for exposed screw or hidden bracket mounting See Figure 6 on page 5 Figure 4 Fi...

Страница 5: ...ct top latch by holding case and pushing up on rod Insert top latch rod into top of stile and into bottom tube Secure with screws indicated in chart Figure 2 on page 3 4 Insert Rods and Secure Top Lat...

Страница 6: ...cases are level at same height Figure 9 2 Drill and tap for No 1 4 20 screws 3 Mount cases 8 Install Inactive Case Figure 7 1 Undog cases Using key furnished back out screw and remove tenon from acti...

Страница 7: ...crossbar over tenon secured to inactive case lever Figure 12 NOTE If crossbar will not slide over tenon loosen screw slightly and tap head of screw with mallet 4 Set other end of crossbar into recess...

Страница 8: ...ll Strikes Top Strike Door C L of Bottom Bolt Backset Figure 15 1 Following template furnished mark bolt backset on outside of door 2 Press in top latch plunger screw to project top latch and bottom b...

Страница 9: ...When door is opened by turning operator latch top latch and bottom bolt should retract and stay retracted until plunger screw is pushed in From Inside When door is opened by depressing crossbar top la...

Страница 10: ...ASSA ABLOY Access and Egress Hardware Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohib...

Страница 11: ...ASSA ABLOY Access and Egress Hardware Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohib...

Страница 12: ...l rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited For installation assistance contact Corbin Ru...

Отзывы: