7
80-9360-6008-152 04/18
DC6210 and DC6410 Series Closers
A13 Heavy Duty Non-Hold Open Parallel Arm
Installation Instructions
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
3
Adjustments
Adjust Spring Power According to Chart
DC6200 Size 1-6 Adjustment (Figure 10)
DC6400 Half Size Adjustment as Desired
• All DC6200 closers are factory set at an
approximate Size 3.
Full Cover (Standard)
Slim Cover (Option M76)
Figure 10
Figure 11
Figure 12
4
Cover Installation
Full Cover (Standard)
Slim Cover (Option M76)
Install Cover (Figure 11)
Slip cover over closer. Hold tightly against
closer mounting surface. Secure on each
side with 6-32 x 1/4 PBHMS screws.
Slim Cover Option M76 only (Figure 12)
Position spindle cap over unused spindle
and secure with truss head screw.
• Adjust closer as necessary for door size
using this chart.
• Readjustment may be required to suit
prevailing conditions.
Size of Door
No. of Full (360°)
Turns Clockwise of
Power Adjuster
Equivalent Closer
Size (Approx.)
Interior
Exterior
In-Swinging
Exterior
Out-Swinging
2' 4"
(712)
2' 6"
(764)
-
4
2
2' 6"
(764)
3' 0"
(915)
-
8
3
3' 0"
(915)
3' 6"
(1067)
2' 6"
(764)
12
4
3' 6"
(1067)
4' 0"
(1219)
3' 0"
(915)
16
5