6) PIP (PoE) Wiring & Installation (Continued)
13. Install Inside Module Component Assembly
Fig. 13a
Fig. 13b
Fig. 13c
Coin Cell
Pull Tab
1. Insert top tabs of controller into slots on mounting plate (Fig. 13a).
2. Ensure proper alignment of board-to-board connectors while
pivoting bottom of controller toward door until tab on bottom
snaps securely into place on mounting plate.
CAUTION
: To avoid possible damage to board-to-board connectors,
care should be taken when securing controller to mounting
plate. If there is resistance when securing, detach controller
to determine cause before re-attaching controller.
3. Connect RJ45 male Connector to female RJ45 on
controller board (Fig. 13b, c).
4. Remove pull tab from its position beneath the coin
cell by pulling on tab in direction of arrows printed
on tab (Fig. 13c).