8
Optional Features
Once power is connected, turn key clockwise to activate alarm. A time delay of 7, 10, 15 or 20 seconds
initiates prior to rail going into an armed state. This allows individualized alarm setting. LED will flash
yellow during this time.
Horn will chirp one (1) time. LED will flash green and repeat every 30 seconds to indicate unit is armed.
Once armed, depress push bar to sound alarm. Rail alarm will sound until disarmed using one (1) of the
following methods:
1. Rail cylinder key
2. Automatic reset (after optional field settable time delay of 2, 5 or 10 minutes)
LED will flash red every 30 seconds to indicate rail has been violated and will continue to flash red until
unit is reset manually. If battery powered and low battery voltage is detected, horn chirps quickly and
repeats every 10 seconds until battery is replaced.
These field selectable switches can change the following functions:
Auto Alarm Reset
Request to Exit/Passage Time Delay
DS3
DS4
Timer Reset
DS1
DS2
Timer Reset
Off
Off
2 minutes
Off
Off
7 seconds
Off
On
5 minutes
Off
On
10 seconds
On
Off
10 minutes
On
Off
15 seconds
On
On
Continuous
On
On
20 seconds