background image

7

6

www.comfimotion.com.au

ComfiMotion is a registered trademark.

Aspire ComfiMotion Adjustable Beds are equipped with functions and features 
engineered to enhance user comfort, independence and safety. Designed for easy, 
multi-positional operation, cleaning and serviceability, this luxurious adjustable bed 
collection uses premium quality materials and finishes. 

 

KEY FEATURES 

 

Maximum safe working load (SWL) of the beds is 250kg with  

a suggested maximum user weight of 200kg which conservatively 

takes into account common accessories such as alternating pressure 

mattresses, assist bars and foam mattresses.

 

•  Floorline positioning 

significantly reduces the risk of falls from a bed.

•  Night Assist: 

Luminous underbed halo for safe entry and exit throughout the night.

•  Box-on-Box Design 

facilitates easier entry and exit and allows true flush positioning 

of beds in companion or dual adjustable bed configurations.

•  Massage: 

Relaxing vibration modes for personalised neck, shoulder and back relief.

•  USB Charge:

 Connect and charge your devices conveniently.

•  Press and Hold Safety Handset:

 Intuitive, large button interface enhances usability. 

•  Enclosed Frame Design:

 Ensures optimal positioning when getting into bed and 

safely covers the moving base platform. 

•  Personalised Positioning:

 Hand control allows users to find their perfect position to 

maximise comfort and relaxation.

•  Personalised Exit Height

 allows a user to preset their bed exit height.

•  Battery backup

 provides the user with confidence that the bed will still operate 

during a power outage.

•  Smart Descent

 ensures user safety when lowering to floor by intermittently stopping 

and then slowing down for final descent.

2. INTRODUCTION

This User Manual outlines the intended use of an Aspire ComfiMotion Adjustable Bed. This 
constitutes how to achieve full functionality, whilst maximising the safety and efficiency of 
carers and users alike. 
It is 

important

 that this User Manual is read in its entirety, prior to operating the bed. The 

manual is designed to ensure that users are equipped with all the information required to 
competently and responsibly operate the bed and its accessories. 
It is recommended that the User Manual be kept in an easily accessible place for quick 
reference. If required Aidacare product specialists can provide additional training. 
All warnings and cautions within this manual should be strictly adhered to. Failure to do so 
could result in harm to the carer or user. 

Warnings

 highlighted throughout this manual identify possible hazards in procedures or 

conditions which if not followed correctly could result in serious injury, or fatality. 

Cautions

 highlighted throughout this manual identify possible hazards in procedures or 

conditions, which if not followed correctly could result in equipment damage, or failure. 

GENERAL

•  Electrical equipment can be hazardous if used incorrectly.
•  The clinically qualified person responsible should consider the age, size and condition 

of the patient before using the bed and its accessories. 

•  The maximum safe working load of the Bed is 250kg and includes the mass of the 

patient, mattress and any accessories fitted to the bed. 

•  The maximum suggested standard mattress thickness for use with ComfiMotion Beds 

is 240mm. 

•  The bed should only be used with approved accessories. Contact Aidacare for a full 

list of approved accessories. 

•  If a patient’s condition could lead to a possible entrapment the mattress support 

platform should be left in the flat position whilst unattended. 

3. SAFETY PRECAUTIONS

150 KG

180 KG

MAX USER WEIGHT

SWL FOR BED

150 KG

180 KG

MAX USER WEIGHT

SWL FOR BED

200KG

250KG

Содержание CombiMotion ACTIV CARE

Страница 1: ...USER MANUAL ACTIV CARE ...

Страница 2: ...es 6 Handset Operation 7 Castor Operation 8 Assembly Instructions 8 1 BEDS How to Unpack Install 8 2 HEADBOARDS How to Assemble or Mount 8 3 ACCESSORIES How to Fit to Bed 8 4 SPLIT KING UPGRADE KIT 9 Storage Movement 10 Cleaning 11 Service Maintenance 12 Troubleshooting 13 Warranty Service 13 1 Beds and Accessories 13 2 Mattresses 14 Service Log Book 5 6 7 9 10 11 15 14 28 29 30 31 32 35 ...

Страница 3: ...ese actions should not be performed at any time or in any circumstances Performing a prohibited action can cause personal injury and or equipment damage On the product this icon is represented as a white symbol with a black circle and black slash MAXIMUM PATIENT WEIGHT This weight represents the total maximum weight of a patient on the bed This weight 200kg should not be exceeded at any time SAFE ...

Страница 4: ...nes the intended use of an Aspire ComfiMotion Adjustable Bed This constitutes how to achieve full functionality whilst maximising the safety and efficiency of carers and users alike It is important that this User Manual is read in its entirety prior to operating the bed The manual is designed to ensure that users are equipped with all the information required to competently and responsibly operate...

Страница 5: ...the bed s functions DO NOT use electrically operated beds in the presence of flammable gases DO NOT use accessories that are not designed or approved for use with ComfiMotion Beds MATTRESS RETAINERS 4x Small Side 1x Long Footend of Bed STANDARD INCLUSIONS x5 HANDSET See Handset Operation for usability instructions x1 OVERALL LENGTH X WIDTH HEIGHT RANGE RECOMMENDED MATTRESS SIZE LxWxH LONG SINGLE B...

Страница 6: ...o avoid being trapped or crushed during bed adjustment Ensure the handset cord is not stretched excessively Ensure the handset and electrical leads cannot become entangled with moving parts of the bed DISCONNECT the power lead from the mains and stow before transporting the bed If the power lead shows any sign of damage replace immediately PLEASE READ THE CRITICAL INFORMATION BELOW UNDERSTANDING T...

Страница 7: ... and legrest 40 to maximise comfort and relaxation 8 Exit Height Lowers mattress deck to flat position and bed to a safe exit height To set custom exit height ensure mattress deck is flat and then raise lower bed to desired height Hold Exit Height 8 and Night Assist 12 buttons for 5 seconds to set the current height 9 Zero Gravity Simultaneously raises the backrest to 20 and legrest also known as ...

Страница 8: ...LATCH UP ComfiMotion Beds come securely packaged in a cardboard carton Inside the carton you will find the retainers and hand control safely secured underneath the bed frame The entire bed is also wrapped for further protection ComfiMotion Beds should arrive to you in pristine condition ready for immediate assembly and installation When opening the carton ensure it is done in a safe and careful ma...

Страница 9: ... void warranty Cut safety securing straps that hold the bed in place when in carton Turn bed FACE UP secure 4 x mattress retainers side and 1 x mattress retainer foot in place by pushing into allocated slots Finally place the mattress onto the bed ensuring all mattress retainers hug the sides and footend Conduct a Factory Reset to ensure control box and actuators are correctly synchronised before ...

Страница 10: ... black upholstery Using the leg stabiliser align the holes to the white markings NOTE The short end of the stabiliser should face the back of the headboard the side that will be positioned against the wall Secure the stabilisers in place using the screws provided 1 2 3 Finally flip the headboard back to its original position enabling it to stand freely 4 Headboard Shortest side Longest end to face...

Страница 11: ...ACCESSORIES BED RAIL BEA830212 CROOK HANDLE BEA830211 HOW TO FIT TO BED BED RAIL BED STICK 8 3 ACCESSORIES OR KIT CONTENTS Bed Rail Crook Handle 1 1 2 5 5 5 3 6 6 2 3 5 Raise bed height backrest and legrest to maximum height for ease of access To adjust Slide the mounting bracket s onto the mounting tube For bed rail Ensure handwheel bolts are pointing towards each other as shown 1 2 Bed once adju...

Страница 12: ...OT intended to be used as a bariatric bed WARNING WARNING WARNING The Split King Upgrade Kit allows two ComfiMotion ACTIV Care Long Single beds to be connected together and act as a Split King bed In this configuration hi lo motors are synchronised so that the two beds lift and tilt together from either handset Headrest backrest legrest massage and under bed light remain independent allowing each ...

Страница 13: ...ch on the LEFT Attach the Junction Box 5 to the RIGHT bed in position shown using the M4 bolts 7 Connect the cord from the Junction Box 5 to port 4 of the control box of the RIGHT bed Use zip ties to secure cable to bed frame if needed Assemble connecting brackets to each of the two beds ensuring the brackets are mounted to the left side of the RIGHT bed and the right side of the LEFT bed NOTE Ens...

Страница 14: ...each other and interlink Ensure both head and foot ends are interlinked 8 9 Gently push on beds to ensure they are interlinked and move side to side together Connect the Electrical Cable from RIGHT bed to the 2nd port of the junction box on LEFT bed Test beds are connected by pressing hi lo button from one handset Both beds should move together To complete set up run a Factory Reset See Section 6 ...

Страница 15: ...g difficulty and centralise the bed centre of gravity for loading Tight Turning Radius Short wheel base with large low resistance castors make manoeuvring through tight spaces manageable Reduce Stock Damage Padded trolley surfaces protect the fragile upholstery of the bed surround reducing damage during freight and handling WHS Outcomes Safety strap and lockable castors make loading and unloading ...

Страница 16: ...ur local authorised Aspire Dealer NOTE Other than general maintenance activities all other service or repair work must be performed by qualified and trained persons or agents approved by Aidacare 11 SERVICE MAINTENANCE Effect Possible Cause Verification Corrective Action BED DOES NOT STAY IN PLACE Locking castors not preventing bed movement Brake System is malfunctioning Not all locking castors ha...

Страница 17: ...f supporting the weight of the mattress and user s This mattress Warranty does not cover your Product if you use it in a manner incompatible with that intended design ii Who is covered by this mattress warranty This limited mattress warranty extends to the original purchaser of an Aspire ComfiMotion Memory Foam and or Pocket Spring mattress who is located in Australia and complies with the product...

Страница 18: ... stained soiled and or otherwise unhygienic The product has been altered or repaired without the Aidacare s prior permission The use of mattress on base slats more than 75 millimetres Physical abuse or damage to the structure and or cover material including but not limited to burns cuts tears heat or liquid damage including bleach or products containing such or stains provided that the defect is c...

Страница 19: ...AIDACARE PTY LTD Building 3A 1 Moorebank Avenue Moorebank NSW Australia 2170 1300 133 120 www aspirecare com au MADE IN PRC ASUM80 10 310122 ...

Отзывы: