The appliance disconnection must be incorporated with an all-pole disconnection device
in the fixed wiring in accordance with the wiring rules.
Any person who is involved with working on or breaking into the refrigerant circuit should
hold a current valid certificate from an industry-accredited assessment authority, which
authorises their competence to handle refrigerants safely in accordance with an industry
recognised assessment specification.
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried
out under the supervision of the person competent in the use of flammable refrigerants.
The equipment shall be properly stored to prevent mechanical damage from occurring.
Keep ventilation openings clear of obstruction.
!
WARNING
The appliances shall be stored in the room without continuous working ignition source
(for example: open flames, an operating gas appliance or an operating electric heater).
Do not pierce or burn the appliances.
Note that the refrigerant may be odorless.
Compliance with national gas regulations shall be observed.
Appliance shall be stored in a well-ventilated area with room size corresponding to the
specified operation area.
2
Appliance shall be installed, operated and stored in a room with a floor area larger than X m ,
2
installation of pipe-work shall be kept to a minimum X m (Please see the following form ).
2
The appliance shall not be installed in an unventilated space, if that space is smaller than Xm
(Please see the following form ).Spaces where refrigerant pipes shall be compliance with
national gas regulations.
NOTE:
The following informations are required for the units adopt R32/R290 Refrigerant.
Model
(Btu/h)
Model
(Btu/h)
Amount of refrigerant
to be charged(kg)
Amount of refrigerant
to be charged(kg)
maximum installation
height(m)
maximum installation
height(m)
Minimum room
2
area(m )
Minimum room
area(
)
2
m
24K
30K-36K
42K
1.25
2.2-2.4
2.8
2.2m
2.2m
2.2m
4
4
5
Grounding is necessary. It may cause electrical shock if grounding is not perfect.
Do not install the unit at place where leakage of flammable gas may occur. In case gas
leaks and accumulates at surrounding of the unit, it may cause fire.