7.  Modules Registers

7.1.  Registered access

Modbus  Dec  Hex 

Register Name

Access

Description

30001

0

0x00 Version/Type

Read

Version and Type of the device

30002

1

0x01 Address

Read

Module Address

40003

2

0x02 Baud rate

Read & Write

RS485 baud rate

40004

3

0x03 Stop Bits & Data Bits

Read & Write

No of Stop bits & Data Bits (see 3.4.2)

40005

4

0x04 Parity

Read & Write

Parity bit

40006

5

0x05 Response Delay

Read & Write

Response delay in ms

40007

6

0x06 Modbus Mode

Read & Write

Modbus Mode (ASCII or RTU)

40010

9

0x09 Filter

Read & Write

Measurement filtering, value from 1 to 10

40033

32

0x20 Received packets MSB

Read & Write

No of received packets

40034

33

0x21 Received packets LSB

Read & Write

40035

34

0x22 Incorrect packets MSB

Read & Write

No of received packets with error

40036

35

0x23 Incorrect packets LSB

Read & Write

40037

36

0x24 Sent packets MSB

Read & Write

No of sent packets

40038

37

0x25 Sent packets LSB

Read & Write

30051

50

0x32 Inputs

Read 

Connected sensors

Bit in high state → sensor is connected

40052

51

0x33 Outputs

Read & Write

Alarms state

bit 2 alarm output

30053

52

0x34 Temperature

Read

Temperature or measured analog 

in mV·10 for voltage to 2048mV
in mV·100 for voltage to 256mV

in °C·10 for temperature

in Ω for resistance

30054

53

0x35 Junction temperature

Read

Module junction temperature

30055

54

0x36 Measurement current

Read

Measurement current

40056

55

0x37 MAX alarm level

Read & Write

If the temperature exceeds this value the

corresponding alarm flag is set

40057

56

0x38 MIN alarm level

Read & Write

If the temperature is below this value  corresponding

alarm flag is set

40058

57

0x39 Alarm settings

Read & Write

Alarm settings

0 – alarm due to the current temperature

1 – Remember the value of the alarm, until reset by the

master via Modbus

40059

58

0x3A Constant junction temperature

Read & Write

Value of junction temperature

40060

59

0x3B Junction temperature offset

Read & Write

Junction temperature offset

Expansion Module – 1 temperature input, 1 digital output

© 

SfAR

 2011 - 2014. All rights reserved.

User Manual

Version 1.0 - 02/01/2014

9 / 12

Содержание Sfar Mini Modbus 1TE

Страница 1: ...Mini Modbus 1TE Expansion Module 1 temperature input 1 digital output Version 1 0 02 01 2014 User Manual Manufactured for...

Страница 2: ...the purposes of commercial law This information does not release you from the obligation of own judgment and verification We reserve the right to change product specifications without notice Please r...

Страница 3: ...n addition the module has one configurable digital outputs PNP or NPN Values are read via RS485 Modbus so we can easily integrate the module with popular PLCs HMI or PC equipped with the appropriate a...

Страница 4: ...1700 C B thermocouple operation range 0 C 1800 C Resistance From 0 to 8000 1 resolution Voltage 0 to 2048mV 0 1mV resolution 0 to 256mV 0 01mV resolution Resistance measuring current 250 A Measurement...

Страница 5: ...te grounding shielding and other protective steps should be taken at the installation stage to prevent these effects These protective steps include control cabinet grounding module grounding cable shi...

Страница 6: ...gistered Read 3 4 40001 Output Registers Registered Read Write 4 6 16 3 4 Communication settings The data stored in the modules memory are in 16 bit registers Access to registers is via MODBUS RTU or...

Страница 7: ...3 0x03 Data Bits MSB 7 7 data bits 8 8 data bits 40006 5 0x05 Response delay Time in ms 40007 6 0x06 Modbus Mode 0 RTU 1 ASCII 4 Indicators Indicator Description ON LED indicates that the module is c...

Страница 8: ...IN DO USB PT100 2 wire measurement V V SUPPLY 10 36V COM INB INA OUT V GND 485 485 VCC GND Mini Modbus 1TE SfAR ON TX IN DO USB Thermocouple measurement V V SUPPLY 10 36V COM INV INA OUT V GND 485 48...

Страница 9: ...rite 30051 50 0x32 Inputs Read Connected sensors Bit in high state sensor is connected 40052 51 0x33 Outputs Read Write Alarms state bit 2 alarm output 30053 52 0x34 Temperature Read Temperature or me...

Страница 10: ...utput is set if value is greater than Alarm Value register 40065 cooling 512 Output is set if value is less than Alarm Value register 40065 heating 40063 62 0x3E Alarm Value Read Write Alarm value for...

Страница 11: ...s of the module This program can be a convenient way to test the system as well as to observe real time changes in the registers Communication with the module is done via the USB cable The module does...

Страница 12: ...gisters 6 3 4 Communication settings 6 3 4 1 Default settings 6 3 4 2 Configuration registers 7 4 Indicators 7 5 Block diagram 8 6 Module Connection 8 7 Modules Registers 9 7 1 Registered access 9 7 2...

Отзывы: