background image

 

       American Stainless Pumps, Inc. 

www.aspumps.com 

7

SSP & SSPC Cross-Sectional Drawings 

SSP (Open Impeller) on top, SSPC (Enclosed Impeller) on bottom. 

Item 

Part 

Materials 

100 

Casing 

304 SS 

200 

Impeller (Open or Enclosed) 

304 SS 

300 

Mechanical Seal – Type 16 

Car/Cer/Buna N/304SS 

 

Other materials: SilCar, Viton, EPR,  

 

400 

Seal Plate 

304 SS 

500 

Casing O-Ring 

Buna N, Viton, EPR 

510 

Impeller O-Ring (Enclosed Imp. Only) 

Buna N, Viton, EPR 

600 

Motor Adapter Plate 

304 SS 

720 

Impeller Shims/Washers (0.010 & 0.015 thick) 

304 SS 

7CS 

Case Screw ¼-20 x ½” 

304 SS 

7DP 

Casing Drain Plug (1/8” NPT) 

304 SS 

7MB 

Motor Bolt (3/8-16 x ½”) 

304 SS 

7SC 

Impeller Washer & Screw (3-phase motors only) 

304SS 

Содержание SSP

Страница 1: ... vs Ceramic faces with Buna N elastomers mechanical seal A maximum temperature limit of 250 deg F is possible with Viton elastomers The motor is limited to 20 starts per hour evenly distributed Minimum flows are 5 of the best efficiency operating point These pumps are not designed for use with hazardous liquids or gasses Notice Upon receipt of this equipment inspect the carton and the equipment fo...

Страница 2: ... on top Do not mount the motor below the pump as leakage from the pump will damage the motor and can cause a shock burns or death Locate the pump as near to the liquid source as possible The pump must be primed with little or no air in the case to begin operation Ideally the pump should be located below the liquid level when starting This pump is not self priming Protect the pump and motor from fr...

Страница 3: ...e the pump beyond the flow rates shown on published curves Noisy pumps or the sounds of pumping rocks may be signs of cavitation or operation beyond the pumps capacity Check pump and motor for vibration Vibration may be a sign of pipe strain insufficient mounting or operation beyond the pumps capacity The pump models SSP SSPC are not designed for handling large amounts of solids For the model SSP ...

Страница 4: ...n while turning the impeller DO NOT apply any heat to the components If you are unable to hold the shaft in this manner remove the rear motor housing and grip the motor shaft with vise grips or other similar device do not hold shaft where bearings will mount 8 Model SSP Only There should be several spacing washers behind the impeller These spacers locate the open impeller vanes close to the case f...

Страница 5: ...kness of impeller spacer washers onto the threaded portion of the shaft If you are not changing the impeller or the motor use the same batch of spacer washers you removed when disassembling the pump See the section on Setting Impeller Clearance for procedures if you are changing the impeller to case setting or are building a new pump 8 Thread the impeller onto the pump shaft and tighten into place...

Страница 6: ... have any spacers when the customer elects to accept reduced performance in return for ease of assembly Use the following impeller shimming method when building a new pump 1 Place the pump as assembled through step 4 of the Assembly section above on the workbench positioned vertically 2 Place 0 050 shims onto the motor shaft two 0 015 shims and two 0 010 shims 3 Thread the impeller onto the shaft ...

Страница 7: ...Mechanical Seal Type 16 Car Cer Buna N 304SS Other materials SilCar Viton EPR 400 Seal Plate 304 SS 500 Casing O Ring Buna N Viton EPR 510 Impeller O Ring Enclosed Imp Only Buna N Viton EPR 600 Motor Adapter Plate 304 SS 720 Impeller Shims Washers 0 010 0 015 thick 304 SS 7CS Case Screw 20 x 304 SS 7DP Casing Drain Plug 1 8 NPT 304 SS 7MB Motor Bolt 3 8 16 x 304 SS 7SC Impeller Washer Screw 3 phas...

Страница 8: ...ld FOB The Factory Freight charges for returning and reshipping products are the buyer s responsibility regardless of warranty status There are no other warranties expressed or implied except for the warranties given here This warranty may not be modified verbally by any employee or agent of ASP Returns All products returned to ASP for warranty evaluation must be authorized in advance by the issua...

Отзывы: