41
trigger will be accepted after 10H:05M:20S. The triggers between
10H:05M:10S to 10H:05M:19S will not be accepted.
If the “Out” is selected for the action, the Interval means “Digital Output On”
period. For example, if Interval set to 20 seconds, when the Digital Input is
triggered, the Digital Output will be “On” and lasting for 20 seconds, and then
“Off” automatically.
Only Detect in Schedule Time:
Enable this option will automatic activate the
Digital-Input detection with scheduled time and stop the detection in the other time.
Please refer to
page to setup the schedule time.
Output Setting
This section is for setup the parameters of Digital Output.
Note: The following settings are available when manually turn on the Relay Out on live
view page.
Mode Settings:
Select the type of the Digital Output switch.
[On/Off Switch]
will be
triggered to On or Off constantly.
[Time Switch]
will be triggered to “On” and lasting
for a period time, and then “Off” automatically.
Interval:
If the Digital Output switch is a “Time Switch”, the lasting time of the “On”
period can be set here.
After set up, click [Apply] to save the settings.