12. Technical specifications
Supply voltage
U
E
24 V AC/DC ±10%
I
E
= 85 mA; I
max
= 180mA (100ms)
Assembly
Plug base for 35 mm DIN snap-on rail mounting
Housing
11-pin DIN plug-base housing with plug
base for 35 mm mounting rail (DIN rail)
Dimensions:
(HxWxD)
Housing
82 x 38 x 84 mm
Housing incl. plug base 82 x 38 x 110 mm
Protection class
IP20
Weight
225 g
Temperature range
-25°C to +55°C
Connection cable cross-section
single- or fine-stranded cable 0,75-1,5 mm
2
Certifications
DIN EN ISO 13849-1:2008 Category 3 PL e
MTTFd 170 years, DC 91%
Elektronik
MTTFd 1616 years, DC 99 %
Elektromechanik
B10d 1000000
MTTFd 190 years (Nop 52560)
Safety device acc. to DIN EN 12978
All voltages connected to the switching unit must
be safely isolated!
Test report no.:
12 205 399386-000
Certificate no.:
44 780 12 399386
EC type-examination no.:
44 205 12 399386
11. Taking out of service and disposal
The products manufactured by ASO are intended solely for commercial use (B2B). At the end of use, the
products are to be disposed of according to all local, regional and national regulations. Products can also be
returned to ASO, which will then dispose of them properly.
Stationary
contact edge
Travelling
contact edge
nominal value
R
nom
= 8,2 kΩ
= 8,2 kΩ
upper switching point
R
AO
> 12 kΩ
> 20 kΩ
lower switching point
R
AU
< 5 kΩ
< 2,5 kΩ
Terminal resistance of the safety contact edges
Nominal current DC
3 A
30 V DC
Nominal current AC
3 A
30 V AC
Mech. life-time
>10
6
actuations
Relay stages
Stationary
contact edge
Travelling
contact edge
Switching off delay (response time)
< 10 ms
< 30 ms
Switching on delay
500 ms (Power on 700 ms)
Safety relay switching times
INDUS rail 71-242
INDUS rail 71-942
82
38
84
110
82
38
84
110
English
Inductive signal transmission system