background image

  

5

PO-1775F

  1.  When installing a new seal, always replace both elements (items 

13 & 14) and install the o-ring (item 11) around the bracket half 

of the seal (item 13). Do not bear directly on the seal surface 

when installing the bracket half. Use a piece of pipe that will bear 

only on the metal flange of the seal case. The impeller half of 

the seal (item 14) may be pressed in with the thumbs. Be sure 

both seal halves are seated squarely with respect to the pump 

shaft.

  2.  During final assembly it is recommended that the 5 screw head 

o-rings (item 8) be replaced. Lubricate these with a 

vegetable

 

type oil only. (DO NOT use petroleum based oil).

  3.  Use a thread locking compound such as Loctite #4 on the 

bracket screw (item 9) threads and on the impeller screw (item 

16) threads.

  4.  The clearance between the impeller (item 15) vanes and the 

volute (item 17) face should be about .015” to .05” for good 

performance. This “front” clearance can be obtained by shim-

ming with the washer type shims (item 30) mentioned in step 3 

of the disassembly instructions. Use the same shims which you 

saved from step 3. Install the impeller (item 15) and firmly press 

on the impeller (

hub only

) while rotating the impeller 360°. If 

scraping is heard, add shim or shims until scraping noise is not 

heard. Install the impeller screw and o-ring (items 16 & 8). Install 

the volute (item 17) and the screws and nuts (items 21 & 4). 

Rotate the shaft while listening for scraping noise. If scraping is 

heard, remove the volute and impeller and remove one washer 

type shim. Repeat this procedure until no scraping is heard.

  5.  Check the impeller vanes for proper height. The following mea-

surements should be found when measuring the vane height at 

the outside perimeter of the impeller (vane tip):

     

 

 

VANE HEIGHT AT

     

*IMPELLER NO. 

TIP OF VANE

     

 

58-0667 

.535”

     

 

58-0704 

.535”

     

 

58-0706 

.535”

     

 

58-0707 

.535”

     

 

58-0708 

.535”

     

 

58-0709 

.535”

     

 

58-0975 

.975”

     

     

*See parts list for further description. The impeller 

curve  letter is the fifth digit of the model number on 

the pump   label. The impeller part number is located 

on each curve  on the flow charts or on the impeller 

itself.

VI. SPECIAL INFORMATION

 

A.  FLEXIBLE COUPLED PUMPS: COUPLING ALIGNMENT

    Measure the diameter of the pump shaft and power unit shaft. 

Choose the appropriate coupling for your pump and power unit. 

(See flexible couplings charge number VI-A). Proper shaft and 

coupling alignment reduces vibration and prevents premature 

coupling failure. The following 8 steps help in obtaining proper 

shaft alignment.

    1.  Make sure you use a rigid base plate large enough for the 

assembly of the pump and the drive unit. We offer kits, 58-008 

and 58-0016, for this purpose. (See base plate kits listed after 

couplings charge VI-A).**

 

 

 

 

 

 

 POWER  

ELECTRIC

 

COUPLING 

UNIT 

MOTOR

 

PART 

SHAFT* 

FRAME

 

NUMBER 

DIAMETER 

SIZES

 

58-0785 

.65” 

56

 

58-0786 

.875” 

143T-145T

 

 

 

 

18-184

 

58-0787 

1.15” 

18T-184T

 

 

 

 

13-15

 

58-0788 

1.375” 

13T, 15T

FLEXIBLE-COUPLINGS CHART VI-A

*One-half  of  each  coupling  has  a  .750”  diameter  bore  to  fit  the 

pedestal pump shaft.

    .  Place the pump and drive unit on the base plate.

    3.  Measure  the  distance  between  the  center  line  of  the 

pump  shaft and the base plate surface.

    4.  Measure  the  distance  between  the  center  line  of  the 

drive  unit shaft and base plate.

    5.  Compare  measurements  obtained  from  steps  3  and  4 

and  use spacer blocks for height adjustment  to insure align-

ment of both shafts.

  6.  Place the coupling halves over each shaft, put the “spider” 

between the two halves and couple the two halves  together.

  7.  To assure parallel alignment (Figure 5) place a straight edge 

along the side of  both coupling halves in two different locations, 

90° apart. The coupling is aligned when the straight edge rests 

squarely on the sides of both coupling halves.

FIGURE 5

INCORRECT

 

PUMP SHAFT   

     DRIVE SHAFT

COUPLING

CORRECT

 

PUMP SHAFT   

 

DRIVE SHAFT

COUPLING

Содержание Pacer Pumps PC Series

Страница 1: ... Verify the chemical compatibility of the materials of your pump with the liquid you want to pump If you are uncertain regard ing chemical compatibility contact your dealer for applications assistance and request a copy of our Corrosion Resistance Charges Do not use a pump that is not chemically compatible with the liquid you intend to pump or serious bodily injury death fire explosion or environm...

Страница 2: ...afety precautions for the handling of fuel b Never refuel the engine while running and care should be exercised so that no fuel is spilled on a hot engine Always allow engine to cool at least two minutes before refu eling 9 Before working on this pump make sure that the power unit cannot inadvertently be started 10 Be sure that the power unit pump wiring and piping installa tions are suitable for ...

Страница 3: ...pump BUNA N ELASTOMERS This pump is equipped with BUNA N elastomers rubber parts BUNA N material is suitable for use with water clean and dirty and other non hazardous liquids Consult factory for additional specific non hazardous application recommendations EPDM ELASTOMERS This pump is equipped with EPDM shaft seal and EPDM static seals These elastomers rubber parts are suitable for use with water...

Страница 4: ...ion end f Impeller speed RPM too low g Worn impeller and or volute See Section V paragraphs 4 5 and 6 V Pump Disassembly and Repair NOTE Pump may be disassembled and repaired using simple screwdriver maintenance See exploded view drawing at end of manual for item numbers mentions 1 Remove the six volute screws and nuts items 21 4 and remove the volute item 17 2 Remove the large o ring item 7 from ...

Страница 5: ...4 535 58 0706 535 58 0707 535 58 0708 535 58 0709 535 58 0975 975 See parts list for further description The impeller curve letter is the fifth digit of the model number on the pump label The impeller part number is located on each curve on the flow charts or on the impeller itself VI SPECIAL INFORMATION A FLEXIBLE COUPLED PUMPS COUPLING ALIGNMENT Measure the diameter of the pump shaft and power u...

Страница 6: ...UMPS If the motor shaft adapter is replaced use the mounting dimen sions shown when installing the new part Plastic Motor Adapter Shaft Adapter T Titanium Mounting Dimension Electric Motor 3 42 2 42 90 ANGLE DRIVE SHAFT FIGURE 6 C PUMP DIMENSIONS OF CENTRAL DISCHARGE PORT SEE NOTE 1 Pump mounted to cast iron bearing pedestal and flexible coupled to motor OF CENTRAL SUCTION PORT SEE NOTE 1 CAST IRO...

Страница 7: ... 275 406 Dia 10 85 10 85 1 056 406 Pump Size J K L M N O P Q R S T 1 2 1 61 4 65 4 55 2 95 406 1 506 6 0 50 1 275 1 25 2 94 3 1 61 4 99 4 55 2 95 406 1 506 6 0 50 1 275 1 25 2 90 Pump Size U V W 1 2 4 17 5 98 4 17 3 4 17 6 50 4 17 Dimensions are in inches OF CENTRAL DISCHARGE PORT SEE NOTE 1 Pump close coupled to motor and mounted on plastic baseplate CENTRAL SUCTION PORT SEE NOTE 1 NOTE 1 THE SUC...

Страница 8: ... 1 58 46250 13 SEAL Shaft 316 Stainless Steel Viton graphite loaded silicon carbide 1 15 58 0667 30 IMPELLER Polyester 3 Vane Open 535 Wide 4 75 Diameter 1 58 0704 30 IMPELLER Polyester 3 Vane Open 535 Wide 5 5 Diameter 1 58 0706 30 IMPELLER Polyester 5 Vane Open 535 Wide 5 5 Diameter 1 58 0707 30 IMPELLER Polyester 5 Vane Open 535 Wide 5 0 Diameter 1 58 0708 30 IMPELLER Polyester 3 Vane Open 535 ...

Страница 9: ...APTER Motor Molded Plastic for pumps close coupled to electric or pneumatic motor 1 45 58 1955 71 SEAL Lip BUNA N 710 ID 2 46 58 0882 90 SHAFT SLEEVE Polyethylene 1 47 58 0884 71 SLINGER BUNA N 1 48 58 1951 90 HOUSING Bearing Cast Iron 1 49 58 1954 90 BEARING Ball 787 ID 2 50 58 1952 10 SHAFT Stainless Steel 75 diameter 1 58 1952 91 SHAFT Hastelloy C 75 diameter 1 51 58 1953 10 PLATE End Stainless...

Страница 10: ...ective component part or product the Buyer shall be entitled to elect a credit at the original buyer s purchase price To return a DEFECTIVE PUMP to return any parts for credit or to obtain service information contact the Service Department After receiving permission to return merchandise the Buyer is authorized to return the product to Pacer Pumps freight prepaid If the company determines that the...