ASM Pacer Pumps PC Series Скачать руководство пользователя страница 2

  

PO-1775F

OPERATOR’S MANUAL FOR:

END-SUCTION CENTRIFUGAL PUMPS

Table of Contents

PLEASE READ SECTIONS I, II AND III BEFORE OPERATING PUMP.

Page no.

 

I.  Safety Precautions ..................................................................................................................................... 2

 

II.  Preparing the Pump for Operation ........................................................................................................... 3

 

III.  Pump Operating Instructions.................................................................................................................... 4

 

IV.  Pump Trouble Shooting and Repair ......................................................................................................... 4

 

V.  Pump Disassembly and Repair ................................................................................................................ 4

 

VI.  Special Information:

 

 

A.  Flexible-coupling: Coupling Alignment .............................................................................................. 5

 

 

 

1.  Couplings

 

 

 

2.  Baseplate Kits

 

 

B.  Close-coupled Electric Motor and Pneumatic Motor Driven Pumps .............................................. 6

 

 

C.  Pump Dimensions .........................................................................................................................6 & 7

 

VII.  Pump Parts List and Parts Diagram .................................................................................................. 8 - 10

OPERATOR’S MANUAL

I.  SAFETY PRECAUTIONS

WARNING:

  1.  Never use these pumps for pumping flammable liquids such 

as gasoline.  

AN EXPLOSION AND SERIOUS INJURY MAY 

RESULT IF THIS WARNING IS IGNORED.

  2.  In  pumping  corrosive  materials,  extreme  caution  should  be 

exercised.    Provide  safety  guards,  ventilation,  and  drains  to 

protect  people  and  property  in  case  of  a  leak  in  the  pump.  

Handling instructions from the manufacturer(s) of the liquids 

being pumped should be closely followed.

  3.  Before starting the pump, follow all of the instructions in this 

manual and any supplemental  instructions supplied  with the 

pump.

  4.  Any person operating this pump and its power unit should be 

fully aware of its safe operation before they start using it.

  5.  Never operate an engine-driven unit in an explosive atmosphere, 

near combustible materials, or where insufficient ventilation ex

-

ists unless specific provisions have been made regarding the 

power unit so as to prevent possible injury and damage.  Be 

certain any other power unit is safe for the area in which it is to 

be operated.

  6.  Always be sure that the unit is on a secure footing and keep the 

immediate pump and power unit area free of all unauthorized 

personnel.  If the pump is sitting beside a pit, be sure it is well 

anchored so that it does not fall in.

  7.  Never operate the unit with any guards removed.

  8.  With engine-driven pumps:

    a.  Observe all safety precautions for the handling of fuel.

 

  b.  Never refuel the engine while running, and care  

 

should be exercised so that no fuel is spilled on a hot engine.  

Always allow engine to cool at least two minutes before refu-

eling.

  9.   Before working on this pump make sure that the power unit 

cannot inadvertently be started.

 10.  Be sure that the power unit, pump, wiring and piping installa-

tions are suitable for the liquid being pumped, and comply with 

all applicable codes and regulations.

 11.  Do not use torches or apply fire or flames to this pumps for any 

reason.

 1.  This pump must not be subjected to more than 65 pounds per 

square inch internal pressure.  The pump itself, normally can-

not develop more than 55 pounds per square inch pressure. 

The pump most 

not

 be used under any of the following unusual 

conditions which can result in excessive pressures being de

-

veloped:

    A.  Pump shaft speed over 3600 RPM.

    B.    Quick closing valves in discharge line or any other device 

which may introduce hydraulic shock into the system.

    C.  Possible  sudden  obstruction  of  discharge  line  such  as 

vehicle driving over hose.

    D.   High positive suction pressures (such as with a flooded 

suction) which would increase the 

total system

 pressure to 65 

PSI or above.

    E.   Do not pump liquids with specific gravities exceeding the 

following values: 

 

 

 

 

 

Maximum

     

 

Impeller* 

Specific Gravity**

     

 

Number 

at 3600 RPM

 

   

 

667 

.1

     

 

707 

1.6

     

 

709 

1.6

     

 

975 

.1

 *The impeller curve letter appears in the model number on the pump 

label.  It is the fifth digit of the model number.

 **The specific gravity is the ration of the weight of the liquid to be 

pumped to the weight of an equal volume of water.  Water has 

a specific gravity of 1.0.  Therefore, a liquid which is heavier 

than water has a specific gravity greater than 1.0.

13.  Do not overtighten the drain plug.  Hand tighten only. Excessive 

force may damage the threads or the pump body.  Do not use 

a metal plug.

14.  Use at least one foot of flexible hose to make plumbing connec

-

tions to the pump.  Rigid piping may put stresses on the pump, 

causing damage. If rigid piping must be used, properly support 

it so as to eliminate stresses on the pump.

Содержание Pacer Pumps PC Series

Страница 1: ... Verify the chemical compatibility of the materials of your pump with the liquid you want to pump If you are uncertain regard ing chemical compatibility contact your dealer for applications assistance and request a copy of our Corrosion Resistance Charges Do not use a pump that is not chemically compatible with the liquid you intend to pump or serious bodily injury death fire explosion or environm...

Страница 2: ...afety precautions for the handling of fuel b Never refuel the engine while running and care should be exercised so that no fuel is spilled on a hot engine Always allow engine to cool at least two minutes before refu eling 9 Before working on this pump make sure that the power unit cannot inadvertently be started 10 Be sure that the power unit pump wiring and piping installa tions are suitable for ...

Страница 3: ...pump BUNA N ELASTOMERS This pump is equipped with BUNA N elastomers rubber parts BUNA N material is suitable for use with water clean and dirty and other non hazardous liquids Consult factory for additional specific non hazardous application recommendations EPDM ELASTOMERS This pump is equipped with EPDM shaft seal and EPDM static seals These elastomers rubber parts are suitable for use with water...

Страница 4: ...ion end f Impeller speed RPM too low g Worn impeller and or volute See Section V paragraphs 4 5 and 6 V Pump Disassembly and Repair NOTE Pump may be disassembled and repaired using simple screwdriver maintenance See exploded view drawing at end of manual for item numbers mentions 1 Remove the six volute screws and nuts items 21 4 and remove the volute item 17 2 Remove the large o ring item 7 from ...

Страница 5: ...4 535 58 0706 535 58 0707 535 58 0708 535 58 0709 535 58 0975 975 See parts list for further description The impeller curve letter is the fifth digit of the model number on the pump label The impeller part number is located on each curve on the flow charts or on the impeller itself VI SPECIAL INFORMATION A FLEXIBLE COUPLED PUMPS COUPLING ALIGNMENT Measure the diameter of the pump shaft and power u...

Страница 6: ...UMPS If the motor shaft adapter is replaced use the mounting dimen sions shown when installing the new part Plastic Motor Adapter Shaft Adapter T Titanium Mounting Dimension Electric Motor 3 42 2 42 90 ANGLE DRIVE SHAFT FIGURE 6 C PUMP DIMENSIONS OF CENTRAL DISCHARGE PORT SEE NOTE 1 Pump mounted to cast iron bearing pedestal and flexible coupled to motor OF CENTRAL SUCTION PORT SEE NOTE 1 CAST IRO...

Страница 7: ... 275 406 Dia 10 85 10 85 1 056 406 Pump Size J K L M N O P Q R S T 1 2 1 61 4 65 4 55 2 95 406 1 506 6 0 50 1 275 1 25 2 94 3 1 61 4 99 4 55 2 95 406 1 506 6 0 50 1 275 1 25 2 90 Pump Size U V W 1 2 4 17 5 98 4 17 3 4 17 6 50 4 17 Dimensions are in inches OF CENTRAL DISCHARGE PORT SEE NOTE 1 Pump close coupled to motor and mounted on plastic baseplate CENTRAL SUCTION PORT SEE NOTE 1 NOTE 1 THE SUC...

Страница 8: ... 1 58 46250 13 SEAL Shaft 316 Stainless Steel Viton graphite loaded silicon carbide 1 15 58 0667 30 IMPELLER Polyester 3 Vane Open 535 Wide 4 75 Diameter 1 58 0704 30 IMPELLER Polyester 3 Vane Open 535 Wide 5 5 Diameter 1 58 0706 30 IMPELLER Polyester 5 Vane Open 535 Wide 5 5 Diameter 1 58 0707 30 IMPELLER Polyester 5 Vane Open 535 Wide 5 0 Diameter 1 58 0708 30 IMPELLER Polyester 3 Vane Open 535 ...

Страница 9: ...APTER Motor Molded Plastic for pumps close coupled to electric or pneumatic motor 1 45 58 1955 71 SEAL Lip BUNA N 710 ID 2 46 58 0882 90 SHAFT SLEEVE Polyethylene 1 47 58 0884 71 SLINGER BUNA N 1 48 58 1951 90 HOUSING Bearing Cast Iron 1 49 58 1954 90 BEARING Ball 787 ID 2 50 58 1952 10 SHAFT Stainless Steel 75 diameter 1 58 1952 91 SHAFT Hastelloy C 75 diameter 1 51 58 1953 10 PLATE End Stainless...

Страница 10: ...ective component part or product the Buyer shall be entitled to elect a credit at the original buyer s purchase price To return a DEFECTIVE PUMP to return any parts for credit or to obtain service information contact the Service Department After receiving permission to return merchandise the Buyer is authorized to return the product to Pacer Pumps freight prepaid If the company determines that the...

Страница 11: ...LODED VIEW PARTS DIAGRAM Figure 7 59 33 56 55 47 46 58 45 57 51 40 50 49 48 45 63 36 33 44 43 32 32 31 39 40 54 52 53 41 33 36 35 32 32 31 29 28 61 64 46 62 65 33 44 43 32 32 31 6 9 12 7 16 22 23 21 17 8 15 30 27 14 13 11 8 4 ...

Отзывы: