background image

Applications / Environment of use

ASL Pro Series equipment is designed for use as a 

wired communications system in theatres, in Radio/TV 

production facilities, in factories, and in utilities com

plexes such as airports, railway stations and coach

terminals.

ASL equipment can be used outdoors in normal 

weather conditions. In conditions with excessive cold 

(<-10° C), heat (>50° C) or humidity (>85%), ASL 

equipment might not perform properly.

ASL equipment is not designed to be used under 

water, or in situations where explosion safe equipment 

is specified by authorities.

Emission

ASL Pro Series equipment does not generate high fre

quency (HF) signals. An ASL power supply can 

generate a weak magnetic field caused by the power 

transformer. To avoid possible negative affects, keep 

ASL power supplies at a safe distance from equipment 

which is very sensitive to magnetic fields.

Immunity

ASL Pro Series is designed on the base of low 

impedance signal transport. User stations and power 

supplies are to be connected via low capacity cabling 

with an overall screen (also see Cabling section). 

Therefore, HF signals are adequately rejected to 

maintain an intelligible communication, unless strong 

electro-magnetic fields (exceeding 3 V/m) are in the 

direct vicinity of the interconnecting cables.

ASL 19" rack mount units are housed in a 1 mm steel 

enclosure (closed construction), which offers, by 

nature, the highest possible rejection of electro-

magnetic fields

ASL speaker stations (PS 130/230/430) are housed in 

an enclosure made of 1 mm steel with ABS side 

panels, which offers adequate rejection of electro-

magnetic fields.

ASL beltpacks are housed in an ABS enclosure and 

are slightly more sensitive to electro-magnetic fields. 

Negative effects in the performance of beltpacks can 

be avoided when keeping them at a safe distance from

equipment which might radiate strong electro-magnetic

fields, such as transmitters antennas and dimmers.

14.0 DESIGN CRITERIA

18

User Manual PS 4379 - Issue 1 © 2007 ASL Intercom, Utrecht, The Netherlands

Содержание PS 4379

Страница 1: ...0 GENERAL DESCRIPTION 4 3 0 UNPACKING 4 4 0 MECHANICAL INSTALLATION 4 5 0 MAINS POWER 5 6 0 FRONT PANEL CONTROLS 6 9 7 0 REAR PANEL CONTROLS 10 11 8 0 INTERNAL CONTROLS 12 14 9 0 MODES 15 10 0 CABLIN...

Страница 2: ...2 User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands...

Страница 3: ...wider than the other This plug will fit only one way into the power outlet This is a safety feature If you are unable to insert the plug fully into the outlet try reversing the plug If the plug still...

Страница 4: ...sound signal A short push of the CALL button will make the LED flash The Call sound signal buzzer will be activated when holding the button for two seconds In case the sound signal is un desirable all...

Страница 5: ...tor which is provi ded to satisfy required local standards WARNING This appliance must be earthed 5 1 POWERING UP Powering up procedure Make sure that the power switch at the back of the unit is OFF C...

Страница 6: ...ute on this channel After the CALL button is released the LEDS will continue to flash for further 2 seconds 4 TALK to ALL When the TALK to ALL button is pressed and held one will talk to all intercom...

Страница 7: ...ch channel control the rejection in the high frequency range It compensates the capacity of the interconnecting cables It prevents the speaker from feeding back into the gooseneck microphone unit feed...

Страница 8: ...this button all buzzers of the connected stations and of the PS 4379 can be muted The buzzers stay muted until the ALL BUZZERMUTE button is switched off again 14 HEADSET connector A XLR 4 type connect...

Страница 9: ...mutes can be locked by pushing a small pin into the SETUP lock It will be unlocked by pushing it again When pushing and holding the set up lock the light intensity of the LEDs of the MIC MUTE BUZZER M...

Страница 10: ...orm a 10 or 12 channel unit When linked 1 station will be the master with an active speaker and goose neck electret microphone The speaker and micro phone of the other unit will be switched off The CA...

Страница 11: ...the external speaker 40 DC POWER INPUT These two connectors allow an external 12 28V DC 5A input as a back up for the internal mains power supply or should no 110 240 V mains supply be available 41 PO...

Страница 12: ...annel C factory setting off Same as for No 4 No 2 CALL RECEIVE Channel B factory setting off Same as for No 4 No 1 CALL RECEIVE Channel A factory setting off Same as for No 4 DIP SWITCH BLOCK A No 6 P...

Страница 13: ...e dip switch is in off position the mic mute signals of the connected intercom system will be routed to the outputs of the PS 4379 If the dip switch is in on position the Mic Mute signals of the conne...

Страница 14: ...d in case of binaural use 44 PGM ROUTING JUMPERS With these two jumpers you can determine for binaural applications how the PGM signal is controlled and where it is to be sent to 8 0 INTERNAL CONTROLS...

Страница 15: ...ode This mode is used for one way communication to dressing rooms etc and can be 1 person to many An AUX signal can be sent to paging receivers of which users can adjust their own listen volume When t...

Страница 16: ...the shield of the cable which functions as the common return for audio and power Since the audio signal is transferred in an unbalanced way certain rules have to be obeyed when installing the cables o...

Страница 17: ...urchase Faults arising from misuse unauthorised modifications or accidents are not covered by this warranty If the unit is faulty it should be sent in it s original packing to the supplier or your loc...

Страница 18: ...base of low impedance signal transport User stations and power supplies are to be connected via low capacity cabling with an overall screen also see Cabling section Therefore HF signals are adequately...

Страница 19: ...User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands 19...

Страница 20: ...20 User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands...

Страница 21: ...User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands...

Страница 22: ...User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands...

Отзывы: