background image

 

4.0 

FRONT PANEL CONTROLS 

 

 

 

MAINS power on/off switch 
 

LED Indicator 

Turns YELLOW if local mains power is fed to the 
unit and turns GREEN if the internal PSU is 
enabled (see section 1.0) 

LED Indicator 

Turns GREEN if 48V DC power is fed to the 
“Intercom Link Out” connector and turns RED if 
there is an overload or short circuit on the 
outgoing intercom line. 

 

5.0     REAR PANEL CONTROLS & CONNECTORS 

 

`

 

 

MAINS entrance  +  FUSE holder  

 

INTERCOM IN connector 

To connect the incoming intercom line

 

 

INTERCOM LINK OUT connector 

To connect the remaining part of the string  

MINI Switch 

If switched “on”, 48V DC power is fed to the 
outgoing intercom line (“Intercom Link Out”), 
provided the internal PSU is enabled.  
If switched “off”, the DS 85 operates as a data 
repeater only.   

 

6.0     TECHNICAL SPECIFICATIONS 

 
Internal Power Supply 

Switch Mode Module 

Mains connection 

 

100 – 240V AC @ 50/60 Hz 

Max. AC Current 

 

2.2 A @ 115 V  or  1.2 A @ 230 V 

 

Power Consumption   

Max. 125 W  

Operating Temperature 

0 to +50 ºC 

Humidity 

 

 

max. 90% RH non-condensing 

Standby Power Supply 

100 – 240 V AC,  < 0.3 Watt 

Dimensions:   

 

Width: 182 mm / Height: 48 mm / Depth: 140 mm. 

Weight:  

 

 

1150 grams 

 

ASL reserves the right to alter specifications without prior notice 

 
 
 
 