background image

 

 

PAGE 2

 

Quick Guide DS 85 / January 2014 © ASL Intercom BV

 

 

 

 

1.0      GENERAL DESCRIPTION 

 
The DS 85 is designed to enforce (repeat) the 
data stream in an intercom line (“string”)  and to 
supply additional 48V DC power to that intercom 
line in case of long cable runs. For this purpose 
the mini switch at the rear panel of the unit has to 
be switched “on”. The 48V power is supplied to 
pin 4 and 5 of the “Intercom Link Out” connector. 
 
If it is not allowed that the intercom system has 
powered intercom lines, the mini switch at the 
rear panel of the DS 85 has to be switched “off”. 
The DS 85 is now a data repeater only.  
 

WARNING

:

 The DS 85 may only be put in the 

‘through intercom line’, so not in the CAT5/CAT6 
cable between a user station and the “Intercom 
Out” of a DS 80 Wall Box, nor in the cable 
between a user station and one the “Intercom 
Out” connectors of a DS 88 Hub. 
 

The DS 85 has to be connected to a local mains 
outlet (100 – 240 V AC, 50/60 Hz, 125 W). 
 

Remotely switching the DS 85 on and off: 

After a matrix unit in an digital intercom system is 
switched on, it sends a handshake signal to its 
intercom lines (strings) which triggers an 
electronic switch inside the DS 85. 
A triggered switch enables the power supply 
section of the unit. As soon as a matrix unit is 
switched off, the handshake signal disappears 
from the intercom line and the DS 85 power 
supply section switches off. 
 

See the ASL Digital User Manual for safety 
instructions and max. CAT5 cable lengths. 

2.0      UNPACKING 

 
The shipping carton contains the DS 85 and this 
quick guide. After unpacking the unit please 
inspect for any physical damage to the unit and 
retain the shipping carton and relevant packing 
materials for use should the unity need returning. 

If any damage has occurred, please notify your 
dealer so that a written claim can be initiated. 
Please also refer to the warranty section of this 
quick guide.

 

3.0     WARRANTY 

 
This unit is warranted by ASL Intercom to the 
original end-user purchaser against defects in 
workmanship and materials in it’s manufacture for 
a period of 12 months from date of shipment to 
the end-user. 
 
 

 
Faults arising from misuse, unauthorised 
modifications or accidents are not covered by this 
warranty. If the unit is faulty, it should be sent in 
it’s original packing to the supplier or local ASL 
dealer, with shipping prepaid. A note must be 
included stating the faults found and a copy of the 
original suppliers invoice. 

 

3.0 

MAINS POWER & SAFETY EARTH 

 

WARNING: This appliance must be earthed ! 

 

Connecting to mains power: 

The DS 85 may be connected to a mains power 
outlet 100 - 240 V AC, 50/60 Hz which provides at 
least 125 watts. The outlet should have a clean 
earth. Avoid using mains power outlets which also 
power dimmer controlled lighting equipment. 
 
The wires in the mains lead are color coded:  
green/yellow:  Earth / safety ground 
blue:   

Neutral 

brown:  

Live 

 
In case the wires in the mains lead do not 
correspond with the colored markings identifying 
the terminals in your mains plug, proceed as 
follows: 

  The wire which is colored green/yellow 

must be connected to the terminal in the 
plug which is marked with the letter “E”, or 
by the ground symbol, or is colored green. 

  The wire which is colored blue must be 

connected to the terminal which is marked 
with the letter “N” or colored black. 

  The wire which is colored brown must be 

connected to the terminal which is marked 
with the letter “L” or colored red. 

 

Safety Earth: 

For personal safety and proper operation of the 
DS 85 the green/yellow wire of the mains lead 
must always be connected to the electrical 
installation safety earth or ground. This wire is in 
the DS 85 connected to all exposed metal 
surfaces.  