background image

Components and measured values

LEVEL SENSOR

Art.no.

80 616 64

ASKO Level sensor type 1166.

Voltage:

0,5 V output from the sensor at pressure 0 and

0-level is reached during pumping out.

Measurement by control unit.

The level sensor is mounted on the bridge for

electrical components and connected to the

PCU, see electrical diagram.

RADIO SUPPRESSION FILTER

Art.no.

80 585 58

Leakage current 230 V/ 50/60 Hz 0,3-0,4 mA

The filter eliminates radio interferences in the

machine.

INLET VALVES
3-way inlet valve

Art.no.

80 617 57

Resistance:

3,7 k

Ω

 ± 0,5 k

Ω

Current:

0,02 A, 5 W

Inlet valve for hot water 

(option)

Art.no.

80 617 29

Resistance:

3,7 k

Ω

 ± 0,5 k

Ω

Current:

0,02 A, 5 W

INDICATING LAMP 

(WM50/55A/66A)

Art.no.

80 640 68  

USA

Current:

230 V, 50 Hz    1,7 mA

Art.no.

80 640 69  

EU

Current:

230 V, 50 Hz     1,7 mA

The lamp indicates that the main switch is tur-

ned on.

DOOR LOCK

Art.no.

80 616 79

Resistance:

122 

Ω

Current:

ca 2 A

The door lock is mechanical and is controlled

by the button for door opening and different

safety devices.

PROGRAM CONTROL CARD 

(WM50/55A)

Art. no.

80 642 57

PROGRAM CONTROL CARD 

(WM66A)

Art. no.

80 642 65

PANEL CARD 

(WM55A/56/66A)

Art.no.

80 642 73  

(ASKO

)

Art.no.

80 642 74  (

OEM

)

Art.no.

80 653 28 

 (ASKO

)

Art.no.

80 653 29 

 (OEM)

FUSE

Art.no.

80 554 21  

6,3 A

 

(EU)

80 581 40  

15 A (US)

Art.nr. 80 800 71 Rev. 1

Содержание WM55A

Страница 1: ...55 New control card New menu logic C New programs Among other things 1 24 hour delayed start New panel graphic Shop program indicated on the display WM56 NEW Electronic control with buttons and displa...

Страница 2: ...ference in operation between the WM55 WM66 and WM55A WM66A is that the new machines are provided with a new menu logic new preset programs new program types and different options The machines also inc...

Страница 3: ...resenting the button you selected to start with P1 P4 appears on the bottom left of the display You can now select the program by pressing the button you selected in Stage 1 N B The option Delayed sta...

Страница 4: ...gram will disappear then next time is pressed or when the machine is switched off Program changed and shown in the display but not stored in the memory P1 P4 The program can now be started with The pr...

Страница 5: ...ows 1 Load the wash and close the door 2 Press the P1 button once 3 Press the Menu button once 4 Step forward with until the Spin or Rinse program appears on the display 5 Press the Enter button once...

Страница 6: ...ons for use Can only be selected for the programs Heavy wash Normal wash and Light wash Pre soak Pre soak On means that the wash will be soaked for two hours before the main program starts Cannot be u...

Страница 7: ...h 60 C 1600 Normal wash 40 C 1200 Light wash 40 C 800 Super quick wash 30 C 800 Hand wash B Preselected programs 3 rinse WM5566 P14 3 P1 P2 P3 P4 Program information Program content 1 3 2 0kg 1 2 3 0...

Страница 8: ...isap pears For programs 4 8 two extra rinses are added before the final normal rinse C Economy run high water level 1500 1500 WM505566 5 Program information Program content P r o g r a m n u m b e r 1...

Страница 9: ...w Temperatureoftheincomingwater 15 C Element power 2000W PROGRAM P1 Cotton linen 60 C 5 0 kg 59 0 95 125 Normal wash P2 Cotton linen 40 C 5 0 kg 59 0 90 85 Light wash P3 Anti crease poly 3 0 kg 22 0 3...

Страница 10: ...iththemainswitch 2 Press 5 x Start Stop S8 S7 S6 S5 S8 S7 S6 S5 3 Wait 30 seconds Step 1 must be executed within 14 seconds Switching off Proceed according to Step 1 and wait 30 seconds before returni...

Страница 11: ...2 S3 S4 S5 S6 S7 S8 S9 S10 5 x S5 Test program Test 1 Test 2 S1 No function S1 No function S2 Inlet valve 1 S2 Drain pump S3 Inlet valve 2 S3 motor Normal action S4 Inlet valve 3 S4 motor Gentle actio...

Страница 12: ...r 0 or 3 secs Setting of water intake 5 x Enter 5 x P4 Change settings with or and the Enter button C Cold Hot and Enter E Mixing Setting of spin speed 5 x 5 x Change settings with left arrow key 1300...

Страница 13: ...keys or 0 3 secs Setting of water intake 5 x Enter 5 x P4 Change settings with the arrow keys and the Enter button C Cold Hot and Enter E Mixing Setting of spin speed 5 x 5 x Change settings with left...

Страница 14: ...ature which may vary from 0 90 C The element is sisconnected if the thermistor is short circuited or disconnected from the program control card or programmer DRAIN PUMP 50 Hz Art no 80 616 96 N B Orde...

Страница 15: ...0 5 k Current 0 02 A 5 W Inlet valve for hot water option Art no 80 617 29 Resistance 3 7 k 0 5 k Current 0 02 A 5 W INDICATING LAMP WM50 55A 66A Art no 80 640 68 USA Current 230 V 50 Hz 1 7 mA Art n...

Отзывы: