41
PERFORMANCE DATA
Program
Maximum load
Temp. °C
Standard ECO
1)
8 / 9 kg (depending
on model)
60 °C
40 °C
Mix/Synthetics
2)
3,5 kg
40
1)
Test program for connection to cold water supply, pursuant to EN 60456.
2)
40 °C program for testing institutes. The 40 °C option has to be set.
ENERGY LABELLING
European test standard
EN 60456
Washing program
Standard ECO
60 °C
40 °C
, 8 / 9 kg cotton
(depending on model)
Connection
Cold water 15 °C
Noise testing method
IEC-60704-2-4
TECHNICAL INFORMATION
Height
850 mm
Width
595 mm
Depth
580 mm
Weight
75 / 76 kg (depending on model)
Drum volume
60 l
Rated power
See rating plate
Heater power
See rating plate
Water pressure
0,1–1 MPa
1–10 kp/cm
2
10–100 N/cm
2
Material for the drum and dispenser
Stainless steel
Housing material
Hot-dip galvanized and powder coated sheet metal, or
stainless steel sheet (depending on model)
Water connection
1.5 m pex hose
Drain hose
1.6 m polypropylene hose
Содержание W2084.W