Selecting the room
• Install the appliance in a dry and well ventilated
room. The appliance will operate correctly if the
environment temperature is in the interval speci
fi
ed
in the table. The appliance class is indicated on the
rating plate / label with the basic information on the
appliance.
Class
Temperature
SN (subnormal)
from +10°C to +32°C
N (normal)
from +16°C to +32°C
ST (subtropical)
from +16°C to +38°C
T (tropical)
from +16°C to +43°C
WARNING!
Make sure the room where the appliance is
installed is large enough. There should be at
least 1 m
3
of space per 8 grams of refrigerant.
Amount of refrigerant is stated on the rating plate
in the appliance interior.
Installing the appliance
Appliance installation should be carried out by at least
two persons to avoid any physical injury or damage to
the appliance.
• The appliance must stand level and stable on a
solid base. At the front, the appliance is
fi
tted with
two adjustable legs that can be used to level the
appliance. At the rear side, casters allow for easier
installation of the appliance (only with some models).
• There should be a clearance of at least 5 cm between
the appliance and any cupboard installed above it, in
order to allow adequate cooling of the condenser unit.
• The appliance is supplied with two spacers which
should be installed on the lower part of the housing
to prevent from pushing the appliance too close to
the wall. Appliance may also be installed without
the spacers; however, this may increase power
consumption.
• Do not expose the appliance to direct sunlight and do
not place it near any source of heat. If this cannot be
avoided, install an insulation panel.
INSTALLATION AND CONNECTION