Connection for hobs with 5 cooking zones:
• 3 phases with 1 zero connection (3 1N, 380 - 415 V~ / 50
Hz): The voltage between the phases and the zero is
220 - 240 V~. The voltage between the phases is 380
- 415 V~. Fit a connecting bridge between connecting
points 4-5. The groups must have fuses of at least
16 A (3x). The core diameter of the connecting cable
must be at least 2.5 mm
2
.
380 -
415 V
220 - 240 V
220 - 240 V
220 - 240 V
380 -
415 V
380 - 415 V
The bridges on the connecting block can be used to
create the required connections, as indicated in these
illustrations.
Fix the cable with a pull relief and close the cover.
Connection point, wall-mounting socket and plug must
be accessible at all times.
Building in
Check that the cabinet and the cut-out meet the
dimension and ventilation requirement.
Threat the sawn ends of wooden or synthetic worktops
with sealing varnish if necessary, to prevent moisture
causing the worktop to swell.
Lay the hob upside down on the worktop.
Fit the connecting cable to the appliance in compliance
with requirements.
Remove the protective layer from the sealing tape and
apply the tape in the groove of the aluminium pro
fi
le
or on the edge of the glass plate. Do not stick tape
round the corners, but cut 4 separate pieces to seal the
corners well.