Connection to water supply
There must be a shut-off tap on the water
supply pipe. The shut-off tap should be
positioned above the work surface or at
the front of the sink unit.
The water supply pipe has a connection
with a 1/2” or 3/4” internal thread depend-
ing on country.
When the installation is complete, the
shut-off tap should be opened to allow the
pressure to settle for a while and to check
that all connections are tight.
NB!
It is recommended that connection should
be to cold water.
Connection to electricity
A dishwasher fitted with a lead and plug
must be connected to an earthed socket, it
must also be placed within reach to the
socket. Repairs and maintenance relating
to safety or performance must be carried
out by a qualified professional.
Technical data
See the type plate on the right side wall.
CAUTION!
The lead must be removed from the socket
while the work is carried out!
Connection to drainage
When the drain hose is routed to a
connection nipple at the sink’s water trap
(see illustration 1), note that the hose must
be fastened level with the underside of the
sink unit – otherwise the dishwater from
the sink can run down into the dishwasher.
The drain hose is threaded onto a cone-
shaped connecting pipe at the sink unit’s
water trap. The cone-shaped pipe must be
cut to an internal diameter of at least 16
mm. For other alternative connections, see
illustrations 2 and 3.
The drain hose may be lengthened by a
maximum of 3 m (the total length of the
drain hose may not exceed 4.5 m). Any
connections and connecting pipes must
have an internal diameter of at least 16
mm. However, the drain hose should
ideally be replaced with a new hose
without joins. Attach the drain hose with a
securing clamp.
No part of the drain hose may be more
than 950 mm above the bottom of the
machine. The hose must not be routed
directly to the floor drain or similar. In such
cases, the hose can act as a siphon and
empty the dishwasher.
NB!
The hose must be fastened level with the
underside of the work surface.
It must be discharged at least 350 mm
above the bottom of the machine.
Max 950 mm
Min 350 mm
Max 950 mm
Min 350 mm
M
ax 3 m
Max 950 mm
Min 350 mm
Illustration 1
Illustration 2
Illustration 3