SRA-Series amplifiers are high-efficiency, lightweight amplifiers incorporating the latest 
amplifier technologies. 
 
The series provides a power range of 75 to 150 watts per channel at 4 ohms (20Hz-20kHz, 
1% THD). The SRA series is available in 2 and 4 channel versions at two power points.  All 
models will drive 4 or 8 ohm loads.  All models are 1RU, with the two and four channel 
versions weighing 9 pounds and 10 pounds respectively. All SRA amplifiers utilize a state-
of-the-art, efficient, high speed switched mode power supply and offer remote power on/off 
among the many standard features. 

 

SRA-Series Power Ratings (per channel) 

 Stereo 

Mono 

Bridged 

Model 

8

 

4

 

8

 

SRA-2075 

40 W

75 W

150 W 

SRA-4075 

40 W

75 W

150 W 

SRA-2150 

80 W

150 W

300 W 

SRA-4150 

80 W

150 W

300 W 

 

• 

Input connections are via 3-pin Euroblock connectors. 

• 

Output connectors are screw terminal strips. 

• 

Rear panel switches include: Gain and Operation Mode. 

 

Protection 

SRA-Series Amplifiers come standard with several protection circuits: 

 

Output over-current protection - 

The output current is limited to safe levels 

regardless of load. 

 

DC output protection - 

The amplifier is switched off if more than 2 volts of 

dc is present on the output. The amplifier will automatically restart after 5 
seconds (if no fault remains). The protect LED is lit as well as the clip LED of 
the affected channel(s). 

 

Main supply rail overvoltage protection - 

The amplifier is switched off if 

the main supply rails have too high of a voltage. The amplifier will 
automatically restart after 5 seconds (if no fault remains). The protect LED is 
lit as well as the clip LED of the affected channel(s). 

 

Chassis internal temperature monitoring - 

The amplifier is switched off 

when the internal ambient temp reaches 70º C. The amplifier will again switch 
on when the internal ambient temp reaches 55º C. The protect LED is lit as 
well as the clip LED of ALL channels. 

 

Inrush limiting - 

The turn-on current is limited. This is active during initial 

startup as well as when exiting standby mode. 

 

Mains fuse - 

There is a 5 amp time delay fuse. 

Important Safety 
Instructions – 2 

Introduction - 3 

The SRA Series - 4 

Protection 

Physical Description - 5 

Installation - 6 

Operation - 8 

Troubleshooting - 9 

Spec Table - 10 

Dimensions - 11 

Warranty - 12 

 

Содержание R-052510

Страница 1: ...fier Operating Manual Ashly Audio Inc 847 Holt Road Webster NY 14580 9103 Toll Free 800 828 6308 Telephone 585 872 0010 FAX 585 872 0739 www ashly com All Trademarks referred to herein are the propert...

Страница 2: ...u la d charge lectrique ne pas exposer cet appareil pour pleuvoir ou l humidit 6 Ne pas utiliser l appareil pr s de l eau 7 Le nettoyer l aide d un tissus sec 8 Ne pas bloquer les ouvertures de ventil...

Страница 3: ...r only the highest quality audio tools at an affordable cost to the professional user ensuring reliability and long life More than thirty years later Ashly remains committed to these principles Ashly...

Страница 4: ...al protection circuits Output over current protection The output current is limited to safe levels regardless of load DC output protection The amplifier is switched off if more than 2 volts of dc is p...

Страница 5: ...ch sets the High Pass Filter for each pair of channels channel to 80Hz or Off The Gain switch sets the amplifier gain to 36dB or 26dB sensitivity The Mode switch selects the amplifier s operating mode...

Страница 6: ...SRA Series amplifiers have specific physical electrical and signal requirements for proper operation These requirements will vary depending on your specific application setup and the settings on the a...

Страница 7: ...al in BRIDGED mode Connectors Polarity SRA Series amplifiers utilize two types of professional audio connectors For the inputs 3 pin Euroblock connectors are utilized with their polarity clearly marke...

Страница 8: ...s operate fully independent of each other Each signal enters the unit and is amplified separately Bridged Mono Mode In this mode a single input is connected to channel 1 or 1 3 in 4 channel models and...

Страница 9: ...he signal source might be clipping Keep the volume pots at least halfway up so that the source does not have to be overdriven Distorted Sound Clip LEDs not lit Keep the volume pots at least halfway up...

Страница 10: ...14 23 Idle BTU hr 61 113 72 137 1 8th Power Pink Noise BTU hr 73 145 111 211 1 3 Power Sine Wave BTU hr 85 150 126 263 Frequency Response 20 Hz 20 kHz 1 0 dB Damping Factor 8 ohm load 1 kHz 200 into...

Страница 11: ...Dimensions All SRA Series amplifiers share the same dimensional measurements Remote Power Connections Important Safety Instructions 2 Introduction 3 The SRA Series 4 Physical Description 5 Installati...

Страница 12: ...ges in design or make additions to or improvements upon this product without any obligation to install the same on products previously manufactured Any implied warranties which may arise under the ope...