Input Ground

The CHASSIS GROUND terminal is internally

connected to the chassis, the AC earth ground, and the
power amplifier’s signal ground.  The INPUT GROUND
terminal is tied to the XLR pin 1 and the 1/4" jack sleeve.
It is recommended that the input and chassis ground ter-
minals remain connected with the factory-supplied jumper
strap.

In situations where the power amp and its signal

source are separated by great distances, a ground voltage
difference may exist between the amp’s chassis ground
and the input cable’s ground.  Connection of these two
grounds through the jumper strap may cause large ground
currents to flow (which is known as a ground loop), caus-
ing a hum noise in the amp’s output. Unless you have such
a situation with a hum problem that cannot be solved by
using balanced input connections, the ground jumper strap
should remain in place.

7.2

Normal/Bridging Switch

This switch selects between NORMAL mode in

the “out” position where both channels are in-phase, and
BRIDGING mode in the “in” position where channel 1
input is used to drive both channels, inverting the phase
of channel 2.  In BRIDGING mode, the channel 1 red bind-
ing post is the (+) in- phase speaker output terminal and
the channel 2 red binding post becomes the (-) out-of-phase
speaker terminal.  It is not necessary to depress the MONO
switch in order to operate in BRIDGED mode.   The
BRIDGING switch overrides either setting of the Stereo/
Mono Switch.

7.3

Stereo/Parallel Mono Switch

This switch selects between STEREO mode in the

“out” position and PARALLEL MONO mode  in the “in”
position.  In PARALLEL MONO mode, channel 1 and
channel 2 inputs are internally tied together before the
input attenuator, allowing discrete channel control of a
mono signal. CAUTION: Be sure not to have two signal
sources connected to ch.1 and ch.2 inputs when in paral-
lel mono mode, as it would short-circuit these two signals
and result in no output.

7.4

Level Controls

The level controls allow attenuation (calibrated

in dB) of the input signal.  In PARALLEL MONO mode,
channel 1 and channel 2 inputs are tied together, while
still preserving independent level control per channel. In
BRIDGED mode, use only channel 1 level control.  It is
recommended that the level controls be operated at full
level (0 dB attenuation) in most situations to maximize
the headroom in the signal source.

7.5

Speaker Outputs - Binding Posts

Caution:  This product can deliver enough

energy to the output terminals to produce a lethal
shock.  Do not attempt to wire the amplifier when
the power is turned on.

A pair of dual banana binding posts provide the

stereo speaker outputs. In BRIDGING mode, the channel
1 red binding post is the (+) in-phase speaker output ter-
minal and the channel 2 red binding post becomes the (-)
out-of-phase speaker terminal.

CAUTION!  NEVER CONNECT THE

TWO RED BINDING POSTS  TOGETHER OR
CONNECT EITHER RED BINDING POST TO
A BLACK BINDING POST!

ono Mode:

dged 

n 2+ is neg

n 1+ is pos

CHANNEL 2

OUTPUT

CHANNEL 1

OUTPUT

1+ is POS
1- is GND

1+ is POS
1- is GND

al Channel

nnector

an.1

n 1+, Pin1-

an.2

n 2+, Pin2-

(-)

(+)

(+)

(-)

BRIDGE

(+)

(-)

1

5

MDA 20A

Channel 2

Ashly

Mad

MF

750 W

1200 W

Figure 7.5:  Output Section

Содержание MFA-6000

Страница 1: ...lip 3 6 9 12 15 18 21 24 27 30 Dual Monaural Amplifier Channel One Output Level Limit Thrm Protect AC Power 0 Clip 3 6 9 12 15 18 21 24 27 30 Channel Two Output Level Limit Thrm Protect MFA 6000 Off O...

Страница 2: ...Mechanical 5 5 2 Cooling 5 6 FRONT PANEL FEATURES 6 6 1 Power Switch 6 6 2 Output Meters 6 6 3 Clipping Indicator 6 6 4 Limit Indicator 6 6 5 Thermal Indicator 7 6 6 Protect Indicator 7 7 REAR PANEL...

Страница 3: ...ize the risk of injury damage or hearing loss please read the entire owner s manual before connecting to a sound system 9 TYPICAL APPLICATIONS 12 9 1 Stereo Operation 12 9 2 Parallel Mono Operation 12...

Страница 4: ...lligently respond to hard clipping overheating excessive high frequency energy and output DC thus preventing damage to the amplifier or the load Status LEDs indicate fault condi tions if any and warn...

Страница 5: ...r s own impedance reducing the power which is actually deliv ered to the speaker It will also result in a decrease in the damping factor and possible fire hazard Since power at the speaker load is a p...

Страница 6: ...serve the relationship between dB below full output and actual clipping 6 3 Clipping Indicator The red CLIP LED is a true clip indicator which monitors the power supply as it is affected by the AC li...

Страница 7: ...Protect Indicator Protect mode in ASHLY amplifiers is automati cally activated during extreme fault conditions as well as during power up and power down When in protect mode as indicated by the red LE...

Страница 8: ...and environment induced hum and noise The signal is on pin 2 of the XLR and the tip of the phone jack The signal is on pin 3 of the XLR and the ring of the phone jack Unbalanced Inputs If an unbalanc...

Страница 9: ...Stereo Parallel Mono Switch This switch selects between STEREO mode in the out position and PARALLEL MONO mode in the in position In PARALLEL MONO mode channel 1 and channel 2 inputs are internally ti...

Страница 10: ...cy interference The transformer option is in stalled within the standard input panel and does not change the operation of any switches or controls 8 2 Peak Limiter Compressor The limiter input option...

Страница 11: ...1 POWERCARD Input Option Two Way 24dB Oct Crossover Installed Crossover Frequency Full Range CAUTION Never Send Full Range Signal To High Frequency Drivers Low Level 5 10 0 5 10 0 1 2KHz 2 4KHz Off Ba...

Страница 12: ...lifier 12 9 TYPICAL APPLICATIONS 9 1 Stereo Operation 9 2 Parallel Mono Operation Both switches out both inputs used both level controls used both outputs used Parallel mono switch in channel 1 input...

Страница 13: ...with the necessary circuitry for computer control and monitoring as this capability becomes available in the future 9 3 Bridged Mono Operation 10 DESIGN THEORY The MFA Series amplifiers are based on...

Страница 14: ...w better ventilation reduce signal levels or increase load impedance by disconnecting some speakers 11 2 Distorted Sound Output level meters indicate 0dB level red CLIP LED on Amplifier is being clipp...

Страница 15: ...15 Operating Manual MFA 8000 and MFA 6000 Power Amplifier 12 DIMENSIONS...

Страница 16: ...MFA 6000 13 8 Voltage Gain 80 38dB 13 9 Input Impedance 20K balanced 13 10 Amplifier Protection Fuseless Short circuit protection ultrasonic and RF protection advanced thermal protection 13 11 Load P...

Страница 17: ...ranty card attached to your product Fill out the information below for your records Model Number_________________________________ Serial Number _________________________________ Dealer _______________...

Страница 18: ...Operating Manual MFA 8000 and MFA 6000 Power Amplifier 18...

Страница 19: ...19 Operating Manual MFA 8000 and MFA 6000 Power Amplifier...

Страница 20: ...r Amplifier ASHLY AUDIO INC 847 Holt Road Webster NY 14580 9103 Phone 716 872 0010 Fax 716 872 0739 Toll Free 800 828 6308 Internet http www ashly com 1997 by Ashly Audio Corporation All rights reserv...

Отзывы: