background image

11

Operating Manual - MFA-8000 and MFA-6000 Power Amplifier

Limiter

In/Out

Level

Channel 2

(+)

(-)

Input

Ground

Chassis

Ground

(-)

(+)

Level

Limiter

In/Out

Channel 1 (Mono)

CL-2

POWERCARD

 Input Option

Stereo Limiter

10

0

1

2

3

4 5

6

9

0

10

1

4 5

6

7

8

9

Limit

Limit

Ch.2

Limiter

Threshold

(dB)

Ch.1

Limiter

Threshold

(dB)

0 -3 -6

-9

-12

-28

+18

+15

+3

+6

0 -3 -6

-9

-12

-28

+18

+15

+3

+6

Norm

Bridge

Stereo

Mono

PUSH

PUSH

PUSH

PUSH

Aux

Low Out

(Pre Level)

Aux

High Out

(Pre Level)

(-)

(+)

Input

Ground

Chassis

Ground

Phase

CD 

Horn EQ

Output
Modes

Ch.2  Ch.1

1.Low   High (FR)
2.Low   Low

3.Bridged Low

   Ch.2 is (+)

1 2 3

+180

0

+360

+180

Highpass

High (FR)

Level

XR-1

POWERCARD Input Option 

Two-Way 24dB/Oct.

Crossover

Installed

Crossover 

Frequency:

Full Range

CAUTION: Never Send Full Range
Signal To High Frequency Drivers.

Low

Level

5

10

0

5

10

0

1.2KHz

2.4KHz

Off

Balanced Input

(Pin 2 Hot)

Input
Level

0

-1

-3

-6

-9

-15

-21

dB

-

PUSH

PUSH

10

0

Mic 1

Level

10

0

Mic 2

Level

10

0

10

0

10

0

Line Level

L = Amplifier Channel 1 Output
R = Amplifier Channel 2 Output

Mono Mode Sums the Stereo Signals

1

2

3

4

Ch.1

Ch.2

Ch.3

Ch.4

Phan.

(+15V)

-1-

-2-

L

R

L

R

Line Inputs

Insert Points

(Post Master Level)

Send

Return

Norm

Bridge

Stereo

Mono

10

9

8

7

6

5

4

3

2

1

0

Microphone Inputs (Mono)

Low-Cut

(Mics Only)

Master

Level

10

0

MM-6

POWERCARD

Input Option

Mic/Line Mixer

PUSH

PUS

H

PUS

H

PUS

H

Figure 8.2:  CL-2
Peak Limiter -
Compressor

Figure 8.3: XR-1
Two-Way
Crossover

Figure 8.4:  MM-6
Mic - Line Mixer

Содержание MFA-6000

Страница 1: ...lip 3 6 9 12 15 18 21 24 27 30 Dual Monaural Amplifier Channel One Output Level Limit Thrm Protect AC Power 0 Clip 3 6 9 12 15 18 21 24 27 30 Channel Two Output Level Limit Thrm Protect MFA 6000 Off O...

Страница 2: ...Mechanical 5 5 2 Cooling 5 6 FRONT PANEL FEATURES 6 6 1 Power Switch 6 6 2 Output Meters 6 6 3 Clipping Indicator 6 6 4 Limit Indicator 6 6 5 Thermal Indicator 7 6 6 Protect Indicator 7 7 REAR PANEL...

Страница 3: ...ize the risk of injury damage or hearing loss please read the entire owner s manual before connecting to a sound system 9 TYPICAL APPLICATIONS 12 9 1 Stereo Operation 12 9 2 Parallel Mono Operation 12...

Страница 4: ...lligently respond to hard clipping overheating excessive high frequency energy and output DC thus preventing damage to the amplifier or the load Status LEDs indicate fault condi tions if any and warn...

Страница 5: ...r s own impedance reducing the power which is actually deliv ered to the speaker It will also result in a decrease in the damping factor and possible fire hazard Since power at the speaker load is a p...

Страница 6: ...serve the relationship between dB below full output and actual clipping 6 3 Clipping Indicator The red CLIP LED is a true clip indicator which monitors the power supply as it is affected by the AC li...

Страница 7: ...Protect Indicator Protect mode in ASHLY amplifiers is automati cally activated during extreme fault conditions as well as during power up and power down When in protect mode as indicated by the red LE...

Страница 8: ...and environment induced hum and noise The signal is on pin 2 of the XLR and the tip of the phone jack The signal is on pin 3 of the XLR and the ring of the phone jack Unbalanced Inputs If an unbalanc...

Страница 9: ...Stereo Parallel Mono Switch This switch selects between STEREO mode in the out position and PARALLEL MONO mode in the in position In PARALLEL MONO mode channel 1 and channel 2 inputs are internally ti...

Страница 10: ...cy interference The transformer option is in stalled within the standard input panel and does not change the operation of any switches or controls 8 2 Peak Limiter Compressor The limiter input option...

Страница 11: ...1 POWERCARD Input Option Two Way 24dB Oct Crossover Installed Crossover Frequency Full Range CAUTION Never Send Full Range Signal To High Frequency Drivers Low Level 5 10 0 5 10 0 1 2KHz 2 4KHz Off Ba...

Страница 12: ...lifier 12 9 TYPICAL APPLICATIONS 9 1 Stereo Operation 9 2 Parallel Mono Operation Both switches out both inputs used both level controls used both outputs used Parallel mono switch in channel 1 input...

Страница 13: ...with the necessary circuitry for computer control and monitoring as this capability becomes available in the future 9 3 Bridged Mono Operation 10 DESIGN THEORY The MFA Series amplifiers are based on...

Страница 14: ...w better ventilation reduce signal levels or increase load impedance by disconnecting some speakers 11 2 Distorted Sound Output level meters indicate 0dB level red CLIP LED on Amplifier is being clipp...

Страница 15: ...15 Operating Manual MFA 8000 and MFA 6000 Power Amplifier 12 DIMENSIONS...

Страница 16: ...MFA 6000 13 8 Voltage Gain 80 38dB 13 9 Input Impedance 20K balanced 13 10 Amplifier Protection Fuseless Short circuit protection ultrasonic and RF protection advanced thermal protection 13 11 Load P...

Страница 17: ...ranty card attached to your product Fill out the information below for your records Model Number_________________________________ Serial Number _________________________________ Dealer _______________...

Страница 18: ...Operating Manual MFA 8000 and MFA 6000 Power Amplifier 18...

Страница 19: ...19 Operating Manual MFA 8000 and MFA 6000 Power Amplifier...

Страница 20: ...r Amplifier ASHLY AUDIO INC 847 Holt Road Webster NY 14580 9103 Phone 716 872 0010 Fax 716 872 0739 Toll Free 800 828 6308 Internet http www ashly com 1997 by Ashly Audio Corporation All rights reserv...

Отзывы: