TROUBLE SHOOTING GUIDE 

 
 

 

GLASS “SOOT’S” UP AT A VERY FAST RATE 

 

FLAME IS LAZY, DARK, AND HAS BLACK TIPS 

 

AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS 

Possible Causes: 

Possible Remedies: 

 

1. 

Stove or vent pipe is dirty, which restricts airflow through the 
burnpot. 

 

 

Follow all cleaning procedure in the maintenance section of the 
owner’s manual. 

 

 

2. 

Vent pipe installed improperly. 

 

 

Check to make sure the vent pipe has been installed according to 
the criteria in the owner’s manual. 

 

 

3. 

Air damper is set too far in (closed) for a higher setting. 

 

 

Pull the damper knob farther out away from the side of the stove and 
try to burn the unit again. 

 

 

4. 

Burnpot holes are blocked. 

 

 

Remove the burnpot and thoroughly clean it. 

 

 

5. 

Air damper is broken. 

 

 

Visually inspect the damper assembly.  Make sure the damper plate 
is attached to the damper rod.  When the damper rod is moved the 
plate should move with it. 

 

 

6. 

Blockage in air intake pipe. 

 

 

Visually inspect the air intake pipe that leads into the burnpot for 
foreign material. 

 

 

7. 

Circuit board malfunction. 

 

 

Time the fuel feed light at each setting (after the stove has 
completed the startup cycle).  Make sure the times match the auger 
timing chart.  If the auger motor runs constantly, the board is bad. 

 

 

8. 

Combustion blower is not spinning fast enough. 

 

 

Test the RPM on the blower after the blades have been cleaned.  
The RPM should be approximately 3000 RPM. 

 

 

9. Bad 

Pellets 

      (Applies to GLASS “SOOT’S” UP AT A VERY FAST RATE Only) 

 

 

The brand of pellets or the batch of pellets that are being used may 
be of poor quality.  If possible, try a different brand of pellets.  You 
might also want to try a brand that is made from a different type of 
wood (softwood vs. hardwood).  Different woods have different 
characteristics when being burned. 

 

 

10.  The trim setting on the low feed rate is to low 
      (Applies to GLASS “SOOT’S” UP AT A VERY FAST RATE Only) 
 

 

 

Use the “Reset Trim” button to increase the low feed rate setting.  If 
the 1 & 3 lights are on, the stove is currently on the lowest setting.  If 
only the 1 light is on, the stove is in the default (medium) setting.  If 
the 1 & 4 lights are on, the stove is in the high trim setting for the low 
feed rate.  If the stove is being burned on one of the two lower 
settings, advance to the next trim setting and try burning the stove. 

 
 

Содержание LUXURY AP2000

Страница 1: ...e fire may result For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area PLEASE read this...

Страница 2: ...ng room heater It is also approved as a mobile home heater which is designed for connection to an outside combustion air source The stove will not operate using natural draft or without a power source...

Страница 3: ...an area where direct sunlight can shine on the unit it is possible this can cause the temperature of the stove to rise to operational levels one of the sensors could then make the stove start on its...

Страница 4: ...ng Door 15 Room Air Fan 15 Re Starting a Warm Stove 15 If Stove Runs Out Of Pellets 16 Damper Control 16 Refueling 16 Ashley Maintenance Tool 16 Shutdown Procedure 16 Safety Features 16 Optional Therm...

Страница 5: ...stallation in residential mobile home and alcove applications The AP2000 Insert is approved for installation into code complying masonry fireplaces The AP2000 Insert is also approved for use in listed...

Страница 6: ...ing vents should not be restricted The flashing should not necessarily seal the fireplace face VENTING The Ashley AP2000 is certified for use with listed TYPE L Vent 3 or 4 diameter in size The stove...

Страница 7: ...ole in wall directly behind stove exhaust vent refer to figure 5 3 Always maintain 3 clearance from combustible materials 4 Install L Vent wall thimble per L Vent manufacturer s instructions 5 Attach...

Страница 8: ...2 After lining up for hole in roof cut either around or square hole in roof always 3 larger all the way around pipe Install upper edge and sides of flashing under roofing materials nail to the roof a...

Страница 9: ...ove adhering to the clearances in Figures 1 2 Mark the center of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to break out the masonry around the location of the pip...

Страница 10: ...installation We suggest painting the interior of particularly old and dirty fireplaces to seal any odors In zero clearance fireplace installations when the fireplace opening is above the floor or rai...

Страница 11: ...CHIMNEY BLANKING PLATE Masonry Fireplaces Only Refer to Figure 15 1 You will need a pipe length that extends 12 above the blanking plate NOTE This installation is optional but not recommended Outside...

Страница 12: ...ng The equipment compartment sides and rear of the stove in fireplace must be enclosed per the applicable electrical standards NOTE Floor protection for Built in raised hearths requires a continuous s...

Страница 13: ...al of the insert to clean the chimney flue A permanent metal warning label must be attached to the back wall of the fireplace opening stating the following This fireplace has been altered to accommoda...

Страница 14: ...d for extended periods of time it can shorten the life expectancy of the room air fan Avoid use at this setting for more than one hour at a time d RESET TRIM Different size and quality pellet fuel and...

Страница 15: ...4 DO NOT use the Fuel Feed button unless you are priming the auger after running out of pellets A dangerous condition could result NOTE During the first few fires your stove will emit an odor as the...

Страница 16: ...and bottom of the hopper b Cleaning heat exchanger tubes see instructions in CLEANING c Scrape ashes from burnpot SHUTDOWN PROCEDURE Turning your Ashley stove off is a matter of pressing the On Off c...

Страница 17: ...OPERATION section of this owner s manual HIGH LOW THERMOSTAT MODE USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT When engaged in this mode the stove will automatically switch between two settings Whe...

Страница 18: ...F ANY EXTERNAL PART OF THE UNIT BEGINS TO GLOW YOU ARE OVERFIRING Immediately press the POWER switch on the control panel h KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES T...

Страница 19: ...rewing the two knobs on the front of the pedestal below the ash lip Dispose of ashes properly See ASH REMOVAL above g Replace ash bin making sure to tighten the knobs and maintaining a good seal h Rep...

Страница 20: ...hese chambers In some cases you will need to remove creosote which can accumulate rapidly under certain conditions A small wire brush can be used It is important to remove this creosote because it is...

Страница 21: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 22: ...22 MAINTENANCE FIGURE 28 AP2000I...

Страница 23: ...tch make sure the ash door is properly latched and the gasket is sealing good If the stove has just a small hole for the ashes to fall through under the burnpot make sure the slider plate is in place...

Страница 24: ...ou until you can lift the shaft out of the stove After you have removed the shaft inspect it for bent flights burrs or broken welds Remove any foreign material that might have caused the jam Also chec...

Страница 25: ...ot sending power to the igniter Check the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out go...

Страница 26: ...emoving the auger pin Remove the auger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out...

Страница 27: ...ion Time the fuel feed light at each setting after the stove has completed the startup cycle Make sure the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Comb...

Страница 28: ...et stoves If there are signs of other types of fuel being used stop using them immediately 4 Power surge or brown out situation A power surge spike or voltage drop could cause the high limit switch to...

Страница 29: ...29 ELECTRICAL DIAGRAM FIGURE 29...

Страница 30: ...A E 033A Door Gasket C G 050 Door Glass Center C D 802 A Door Glass Side C D 802 B Exhaust Adapter 4 A 4 VA Hot Rod Igniter C E IGN Remote Thermostat RF Acumen Optional AG RCN Thermodisc Proof of Fire...

Отзывы: