16 OPERATIONS 

 

RE-STARTING A WARM STOVE 

 

If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.

 

 
IF STOVE RUNS OUT OF PELLETS

 

 
The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes. 
After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes. 
After the 10 minutes the “3” light on the bar graph will flash and the “On/Off” light will go off. 
To restart, refill hopper and press “Fuel Feed” button until pellets begin to fall into burnpot. Press “On/Off” button. 
 

REFUELING

 

 
We recommend that you not let the hopper drop below ¼ full.  
 

KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. THE HOPPER MAY BE FILLED WHILE THE STOVE IS 
OPERATING. DO NOT OVERFILL HOPPER.  
 

ASHLEY MAINTENANCE TOOL

 

 
A tool has been provided to help with the following functions:  

 

a. 

Stirring pellets in hopper

 – unlike liquids in a tank, pellets do not drain evenly into the auger. Bridging across the opening can occur. 

Pellets can hang up on the sides of the hopper. Occasionally “stirring” the hopper can help. 

 

NOTE: 

To help prevent bridging of pellets, common wax paper can be rubbed on the sidewalls and bottom of the hopper. 

 

b. 

Cleaning heat exchanger tubes – 

see instructions in “

CLEANING

”. 

 
c. 

Scrape ashes from burnpot.

 

 

SHUTDOWN PROCEDURE 

 
Turning your Ashley stove off is a matter of pressing the “On/Off” control panel switch. The green light will go out. The blowers will continue 
to operate until internal firebox temperatures have fallen to a preset level. 
 

SAFETY FEATURES 

 
a. 

Your stove is equipped with a high temperature thermodisc. This safety switch has two functions. 

 

g. 

To recognize an overheat situation in the stove and shut down the fuel feed or auger system. 

 
h. 

In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut down the auger, preventing 
the stove from overheating. 

 

NOTE: 

On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting your stove. On other 

units the thermodisc has no reset button and will reset itself once the stove has cooled. The manufacturer recommends that you call your 
dealer if this occurs as this may indicate a more serious problem. A service call may be required. 
 
b. 

If the combustion blower fails, an air pressure switch will automatically shut down the auger. 

 

NOTE:

 Opening the stove door for more than 30 seconds during operation will cause enough pressure change to activate the air switch, 

shutting the fuel feed off. Close the door and press “On/Off” button to continue operation of your stove. 

FIGURE 20 

Содержание LUXURY AP2000

Страница 1: ...e fire may result For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area PLEASE read this...

Страница 2: ...ng room heater It is also approved as a mobile home heater which is designed for connection to an outside combustion air source The stove will not operate using natural draft or without a power source...

Страница 3: ...an area where direct sunlight can shine on the unit it is possible this can cause the temperature of the stove to rise to operational levels one of the sensors could then make the stove start on its...

Страница 4: ...ng Door 15 Room Air Fan 15 Re Starting a Warm Stove 15 If Stove Runs Out Of Pellets 16 Damper Control 16 Refueling 16 Ashley Maintenance Tool 16 Shutdown Procedure 16 Safety Features 16 Optional Therm...

Страница 5: ...stallation in residential mobile home and alcove applications The AP2000 Insert is approved for installation into code complying masonry fireplaces The AP2000 Insert is also approved for use in listed...

Страница 6: ...ing vents should not be restricted The flashing should not necessarily seal the fireplace face VENTING The Ashley AP2000 is certified for use with listed TYPE L Vent 3 or 4 diameter in size The stove...

Страница 7: ...ole in wall directly behind stove exhaust vent refer to figure 5 3 Always maintain 3 clearance from combustible materials 4 Install L Vent wall thimble per L Vent manufacturer s instructions 5 Attach...

Страница 8: ...2 After lining up for hole in roof cut either around or square hole in roof always 3 larger all the way around pipe Install upper edge and sides of flashing under roofing materials nail to the roof a...

Страница 9: ...ove adhering to the clearances in Figures 1 2 Mark the center of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to break out the masonry around the location of the pip...

Страница 10: ...installation We suggest painting the interior of particularly old and dirty fireplaces to seal any odors In zero clearance fireplace installations when the fireplace opening is above the floor or rai...

Страница 11: ...CHIMNEY BLANKING PLATE Masonry Fireplaces Only Refer to Figure 15 1 You will need a pipe length that extends 12 above the blanking plate NOTE This installation is optional but not recommended Outside...

Страница 12: ...ng The equipment compartment sides and rear of the stove in fireplace must be enclosed per the applicable electrical standards NOTE Floor protection for Built in raised hearths requires a continuous s...

Страница 13: ...al of the insert to clean the chimney flue A permanent metal warning label must be attached to the back wall of the fireplace opening stating the following This fireplace has been altered to accommoda...

Страница 14: ...d for extended periods of time it can shorten the life expectancy of the room air fan Avoid use at this setting for more than one hour at a time d RESET TRIM Different size and quality pellet fuel and...

Страница 15: ...4 DO NOT use the Fuel Feed button unless you are priming the auger after running out of pellets A dangerous condition could result NOTE During the first few fires your stove will emit an odor as the...

Страница 16: ...and bottom of the hopper b Cleaning heat exchanger tubes see instructions in CLEANING c Scrape ashes from burnpot SHUTDOWN PROCEDURE Turning your Ashley stove off is a matter of pressing the On Off c...

Страница 17: ...OPERATION section of this owner s manual HIGH LOW THERMOSTAT MODE USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT When engaged in this mode the stove will automatically switch between two settings Whe...

Страница 18: ...F ANY EXTERNAL PART OF THE UNIT BEGINS TO GLOW YOU ARE OVERFIRING Immediately press the POWER switch on the control panel h KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES T...

Страница 19: ...rewing the two knobs on the front of the pedestal below the ash lip Dispose of ashes properly See ASH REMOVAL above g Replace ash bin making sure to tighten the knobs and maintaining a good seal h Rep...

Страница 20: ...hese chambers In some cases you will need to remove creosote which can accumulate rapidly under certain conditions A small wire brush can be used It is important to remove this creosote because it is...

Страница 21: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 22: ...22 MAINTENANCE FIGURE 28 AP2000I...

Страница 23: ...tch make sure the ash door is properly latched and the gasket is sealing good If the stove has just a small hole for the ashes to fall through under the burnpot make sure the slider plate is in place...

Страница 24: ...ou until you can lift the shaft out of the stove After you have removed the shaft inspect it for bent flights burrs or broken welds Remove any foreign material that might have caused the jam Also chec...

Страница 25: ...ot sending power to the igniter Check the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out go...

Страница 26: ...emoving the auger pin Remove the auger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out...

Страница 27: ...ion Time the fuel feed light at each setting after the stove has completed the startup cycle Make sure the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Comb...

Страница 28: ...et stoves If there are signs of other types of fuel being used stop using them immediately 4 Power surge or brown out situation A power surge spike or voltage drop could cause the high limit switch to...

Страница 29: ...29 ELECTRICAL DIAGRAM FIGURE 29...

Страница 30: ...A E 033A Door Gasket C G 050 Door Glass Center C D 802 A Door Glass Side C D 802 B Exhaust Adapter 4 A 4 VA Hot Rod Igniter C E IGN Remote Thermostat RF Acumen Optional AG RCN Thermodisc Proof of Fire...

Отзывы: