2 INTRODUCTION 

Thank you for purchasing the Ashley Pellet Burning Stove. You are now prepared to burn 
wood in the most efficient, convenient way possible. To achieve the safest, most efficient and 
most enjoyable performance from your stove, you must do three things: 1) Install it properly; 
2) Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you 
do all three.  
 

PLEASE read this entire manual before installation and use of this pellet fuel-burning 
room heater. Failure to follow these instructions could result in property damage, 
bodily injury or even death. 
 
Keep this manual handy for future reference. 

 
Your Ashley AP2000 comes as a fireplace insert or as a freestanding stove with a pedestal. 
 
This stove has been independently tested to ASTM E1509-12 Standard Specification for 
Room Heaters, Pellet Fuel Burning Type 1, ULC-S627 Standard for Solid Fuel Room 
Heaters, and Oregon Administrative Rules for Mobile Homes (814-23-900 through 814-23-
909) and Installation as a Stove Heater. 
 
This pellet stove, when installed, must be electrically grounded in accordance with local 
codes, or in the absence of local codes, with the 

National Electrical Code, ANSI/NFPA 70

 
This appliance is designed specifically for use only with pelletized wood. It is designed for 
residential installation according to current national and local building codes as a freestanding 
room heater. It is also approved as a mobile home heater which is designed for connection to 
an outside combustion air source. 
 
The stove will not operate using natural draft or without a power source for the blower 
systems and fuel feed system and must not be burned with any type of coal (see 

PROPER 

FUEL

). 

 
This stove is designed to provide the optimum proportions of fuel and air to the fire in order to 
burn free of smoke and soot. Any blockage of the air supply to or from the stove will seriously 
degrade its performance and will be evidenced by a smoking exhaust and a sooting window. 
For best operation the ash content of the pellet fuel should be less than 1% and the calorific 
value approximately 8200 BTU/LB. Avoid high ash content fuels because this will rapidly fill 
up the burn pot and eventually cut off the combustion air supply. 
 
Commercial and industrial installations of Ashley Pellet Stoves should not be used since 
operational control is often not well managed in these settings.

IMPORTANT INFORMATION 

 
Model: _____AP2000  ________________ 
Style: ____________________________ 
Serial Number:_____________________ 
Purchase Date: ____________________ 
Purchased From:___________________ 
 

 

      ___________________ 

 

 

      ___________________ 

MAIL YOUR WARRANTY CARD TODAY 

To receive full warranty coverage, you will 
need to show evidence of the date you 
purchased your stove. We suggest that 
you attach your sales invoice to this page, 
and fill in the form on the left, so that you 
will have all the information you need in 
one place should the need for service or 
information occur. 

Содержание LUXURY AP2000

Страница 1: ...e fire may result For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area PLEASE read this...

Страница 2: ...ng room heater It is also approved as a mobile home heater which is designed for connection to an outside combustion air source The stove will not operate using natural draft or without a power source...

Страница 3: ...an area where direct sunlight can shine on the unit it is possible this can cause the temperature of the stove to rise to operational levels one of the sensors could then make the stove start on its...

Страница 4: ...ng Door 15 Room Air Fan 15 Re Starting a Warm Stove 15 If Stove Runs Out Of Pellets 16 Damper Control 16 Refueling 16 Ashley Maintenance Tool 16 Shutdown Procedure 16 Safety Features 16 Optional Therm...

Страница 5: ...stallation in residential mobile home and alcove applications The AP2000 Insert is approved for installation into code complying masonry fireplaces The AP2000 Insert is also approved for use in listed...

Страница 6: ...ing vents should not be restricted The flashing should not necessarily seal the fireplace face VENTING The Ashley AP2000 is certified for use with listed TYPE L Vent 3 or 4 diameter in size The stove...

Страница 7: ...ole in wall directly behind stove exhaust vent refer to figure 5 3 Always maintain 3 clearance from combustible materials 4 Install L Vent wall thimble per L Vent manufacturer s instructions 5 Attach...

Страница 8: ...2 After lining up for hole in roof cut either around or square hole in roof always 3 larger all the way around pipe Install upper edge and sides of flashing under roofing materials nail to the roof a...

Страница 9: ...ove adhering to the clearances in Figures 1 2 Mark the center of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to break out the masonry around the location of the pip...

Страница 10: ...installation We suggest painting the interior of particularly old and dirty fireplaces to seal any odors In zero clearance fireplace installations when the fireplace opening is above the floor or rai...

Страница 11: ...CHIMNEY BLANKING PLATE Masonry Fireplaces Only Refer to Figure 15 1 You will need a pipe length that extends 12 above the blanking plate NOTE This installation is optional but not recommended Outside...

Страница 12: ...ng The equipment compartment sides and rear of the stove in fireplace must be enclosed per the applicable electrical standards NOTE Floor protection for Built in raised hearths requires a continuous s...

Страница 13: ...al of the insert to clean the chimney flue A permanent metal warning label must be attached to the back wall of the fireplace opening stating the following This fireplace has been altered to accommoda...

Страница 14: ...d for extended periods of time it can shorten the life expectancy of the room air fan Avoid use at this setting for more than one hour at a time d RESET TRIM Different size and quality pellet fuel and...

Страница 15: ...4 DO NOT use the Fuel Feed button unless you are priming the auger after running out of pellets A dangerous condition could result NOTE During the first few fires your stove will emit an odor as the...

Страница 16: ...and bottom of the hopper b Cleaning heat exchanger tubes see instructions in CLEANING c Scrape ashes from burnpot SHUTDOWN PROCEDURE Turning your Ashley stove off is a matter of pressing the On Off c...

Страница 17: ...OPERATION section of this owner s manual HIGH LOW THERMOSTAT MODE USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT When engaged in this mode the stove will automatically switch between two settings Whe...

Страница 18: ...F ANY EXTERNAL PART OF THE UNIT BEGINS TO GLOW YOU ARE OVERFIRING Immediately press the POWER switch on the control panel h KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES T...

Страница 19: ...rewing the two knobs on the front of the pedestal below the ash lip Dispose of ashes properly See ASH REMOVAL above g Replace ash bin making sure to tighten the knobs and maintaining a good seal h Rep...

Страница 20: ...hese chambers In some cases you will need to remove creosote which can accumulate rapidly under certain conditions A small wire brush can be used It is important to remove this creosote because it is...

Страница 21: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 22: ...22 MAINTENANCE FIGURE 28 AP2000I...

Страница 23: ...tch make sure the ash door is properly latched and the gasket is sealing good If the stove has just a small hole for the ashes to fall through under the burnpot make sure the slider plate is in place...

Страница 24: ...ou until you can lift the shaft out of the stove After you have removed the shaft inspect it for bent flights burrs or broken welds Remove any foreign material that might have caused the jam Also chec...

Страница 25: ...ot sending power to the igniter Check the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out go...

Страница 26: ...emoving the auger pin Remove the auger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out...

Страница 27: ...ion Time the fuel feed light at each setting after the stove has completed the startup cycle Make sure the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Comb...

Страница 28: ...et stoves If there are signs of other types of fuel being used stop using them immediately 4 Power surge or brown out situation A power surge spike or voltage drop could cause the high limit switch to...

Страница 29: ...29 ELECTRICAL DIAGRAM FIGURE 29...

Страница 30: ...A E 033A Door Gasket C G 050 Door Glass Center C D 802 A Door Glass Side C D 802 B Exhaust Adapter 4 A 4 VA Hot Rod Igniter C E IGN Remote Thermostat RF Acumen Optional AG RCN Thermodisc Proof of Fire...

Отзывы: