SELECTING A LOCATION FOR THE HEATER

When selecting a location for the heater, be sure attention is given to the following considerations:
1.  If the heater is to be vented into a Listed High Temperature Type HT Factory-Built Residential Type And
    Building Heating Appliance Chimney, review the installation instructions for the chimney to comply with
     requirements for proper chimney location, height, space requirements, etc.
2.  If the heater is to be vented into a masonry chimney, the heater should be located as near the chimney as pos-
    sible without failing to comply with the requirements for minimum spacing between the chimney connector,
     heater and combustibles. (Be sure chimney is constructed according to NFPA standards.)
3.  The location  of the heater must provide at least the minimum clearances between the heater, chimney connector
     and combustible materials as specified by figures 1, 2, 3, 4.
4.  If the heater is to be located on a combustible floor, there must be suitable floor space to install a floor protector
     beneath and extending beyond the heater as shown by figure 5 and as described by the Floor Protection
    section of this manual.
5.  The heater should be located centrally within the area where heat is desired but out of traffic areas to minimize
    the likelihood of persons accidentally contacting the hot surface of the heater.
6.  The heater should be located away from doorways and central heat outlets and inlets to reduce the chance of
     drafts blowing smoke, ashes or sparks out of the heater during refueling or ash removal.
7.  The heater should be located where a small supply of wood may be kept conveniently close but not within 36
     inches of the heater.
8.  Locate the heater so that drapes, curtains, furniture and other combustible materials will not be closer than the
    clearances shown by figures 1, 2, 3, and 4 OR install a clearance reduction system.  See MINIMUM CLEAR
    ANCES TO COMBUSTIBLE WALLS AND CEILINGS section of this manual for details.

FIGURE 1 - MINIMUM CLEARANCES
TO COMBUSTIBLES

FIGURE 2 - MINIMUM CLEARANCES TO
COMBUSTIBLES

BUILDING CODES AND SAFETY STANDARDS

These instructions comply with the applicable 

National Fire Protection Association and Underwriters’ Laboratories, Inc.

Standards for the installation and operation of this type heater.  Before beginning the installation, you should check  with
local building officials to assure compliance with local regulations and codes.
This heater is safety listed by Warnock Hersey International, Inc. as specified by the listing label attached to the heater.

HOW THIS HEATER OPERATES

The chimney draft draws in combustion air through an adjustable air inlet thermostat located inside the cabinet.  Air
flows through and across the bed of fuel, causing the fire to progress through the fuel bed.  Heat is transferred to the air
that flows between the cabinet and the firebox.  Any attempt to alter this air by connecting this heater to a duct system
or air movement fans other than the optional KB902 listed blower, available from your heater dealer, can lead to im-
proper and possibly hazardous operation of this heater.

Содержание EC95

Страница 1: ...ULT FOR YOUR SAFETY FOLLOW THE INSTALLATION INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC TIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA To assure that satisfactory...

Страница 2: ...chance of drafts blowing smoke ashes or sparks out of the heater during refueling or ash removal 7 The heater should be located where a small supply of wood may be kept conveniently close but not wit...

Страница 3: ...EC95 3 FIGURE 3 MINIMUM CLEARANCES TO COMBUSTIBLES FIGURE 4 MINIMUM CLEARANCES TO COMBUSTIBLES SIDE SECTION VIEW PLAN SECTION VIEW...

Страница 4: ...btained from N F P A Inc Batterymarch Park Quincy MA 02269 The Chimney connector pipe from heater to chimney must be 6 inches in diameter and made from 24 gauge or heavier steel The length of the chim...

Страница 5: ...el supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold the chimney section Fasteners used to secure chimney sections shall not penetrate chimney flue l...

Страница 6: ...RICK ALL AROUND CHIMNEY CONNECTOR TO HEATER FIRE CLAY LINER 5 8 MIN WALL THICKNESS MIN 3 1 2 THICK BRICK MASONRY WALL MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 MINIMUM 12 IN TO COMBUSTIBLES PART A FIGUR...

Страница 7: ...RY CHIMNEY CONSTRUCTED TO NFPA 211 SHEET STEEL SUPPORTS 24 GAUGE MIN THICKNESS CHIMNEY CONNECTOR TO HEATER MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN MINIMUM...

Страница 8: ...O APPLIANCES OR HEATERS ARE CONNECTED TO THE SAME FLUE CAUTION THE HEATER MUST BE PLACED ON A LISTED FLOOR PROTECTOR AS NOTED IN THIS MANUAL IF THE FLOOR IS WOOD OR OTHER COMBUSTIBLE FLOORING IF CARPE...

Страница 9: ...obtain the fireplace items called for by figure 4 3 If the heater is to be installed on a combustible floor purchase a listed noncombustible floor protector as described in this manual and install it...

Страница 10: ...UILD A FIRE 1 Set the heater s thermostat control knob to the Hi position See figure 9 2 Open the feed door see figure 10 and lay paper and kindling on the rate in sufficient quantities to ensure good...

Страница 11: ...driven off and shortens the length of time the dense smoke is likely to deposit creosote on the chimney walls 5 DO NOT TAMPER WITH THE INTERNAL THERMOSTAT MECHANISM The thermostat has been designed a...

Страница 12: ...or several days when embedded in ashes VENTING SYSTEM CHIMNEY CONNECTOR AND CHIMNEY The venting system consists of the heater s chimney connector the pipe which connects the heater to the chimney and...

Страница 13: ...at has grown tall can affect the draft of a chimney that was previously trouble free and other factors The common unit used to measure draft is INCHES IF WATER To determine the draft of your chimney a...

Страница 14: ...ns as cleanly as possible Thus you should adjust the amount of wood you put in the heater to the outdoor temperature Placing excessive wood in the heater will cause excessive creosote formation in the...

Страница 15: ...omposition fire starters specifically designed for starting a fire The use of liquid fire starters can cause an explosion within the heater 14 Do use only a Listed High Temperature Type HT Factory bui...

Страница 16: ...t 11 Don t install this heater in a chimney flue that is used by another appliance 12 Don t neglect to clean and inspect your chimney regularly 13 Don t operate this heater with the doors open 14 Don...

Страница 17: ...EC95 17 FIGURE 12 ILLUSTRATION OF REPAIR PARTS SEE LEDGER ON NEXT PAGE FOR PART NAMES AND PART NUMBERS 47 58...

Страница 18: ...Ash Door 1 88057 18 Feed Door Assy 1 69229 19 Latch 1 25048 20 Liner Front 1 40412 22 Shield Door Ptd 1 24870 23 Pan Ash Welded 1 69206 24 Grate 2 40394 25 Angle Grate Support Assy 2 69205 26 Leveler...

Страница 19: ...k for Mechanical Engineers by Baumeister and Marks 6 K C and R factors are explained as follows A The K factor represents the thermal conductivity of a material and is the time rate of heat flow throu...

Страница 20: ...20 EC95...

Отзывы: