SEE FIGURE 12 FOR ILLUSTRATION OF PARTS

CUSTOMER NOTE: IN ADDI-
TION TO THE REPAIR PARTS,
KITS INCLUDE ANY RE-
PLACEMENT FASTENERS
WHICH WILL MOST LIKELY BE
NEEDED TO INSTALL THE
REPAIR PART.

SAVE THIS MANUAL FOR FUTURE REFERENCE

KEY

QTY.

EC95

NO.

PART NAME

Per Unit

PART NO.

1

Inner Unit Assy. Ptd.

1

69228B

2

Gasket

1

88094

3

Collar Flue

1

24819

4

Retainer Rear Brick

1

40381

5

Retainer Side Brick

2

40132

6

Brick

13

89066

7

Rod Smoke Curtain

1

24846

8

Curtain Smoke Ptd. Assy.

1

24834

9

Rope Gasket for Feed Door

1

88057

10

Door pin

4

83485

11

Hinge for Feed Door

1

24837

12

Shield Handle Radiation

1

24828

13

Handle

2

89930

14

Hinge for Ash Door

1

24838

15

Ash Door Assy.

1

69230

16

Latch for Ash Door

1

25048

17

Rope Gasket for Ash Door

1

88057

18

Feed Door Assy.

1

69229

19

Latch

1

25048

20

Liner, Front

1

40412

22

Shield Door Ptd.

1

24870

23

Pan Ash Welded

1

69206

24

Grate

2

40394

25

Angle Grate Support Assy.

2

69205

26

Leveler

4

83479

27

Gasket Manifold

1

88090

28

Manifold Assy. Ptd.

1

24812

29

Plate Draft Assy. Ptd.

1

69207B

30

Clip Spring

1

83890

31

Draft Pin

1

25550

32

"S" Hook

2

83482

33

Chain

2.5 Ft.

86318

34

Thermostat Assy.

1

69223

45

Knob

1

89924

46

Plate Control

1

851397

47

Panel Top Front

1

24865

48

Trim & Screen Ptd. Assy.

1

69224GO

49

Brace Lt. & Rt. Top Ptd.

2

24851

50

Shield Radiation Kit

1

24824

51

Side left Cab. Ptd. Assy.

1

69221TX

52

Top Cabinet Assy. Ptd.

1

69202TX

53

Handle Cabinet Top Kit

1

89925

54

Back Panel Assy. Ptd.

1

69203TX

55

Side Right Cab. Assy. Ptd.

1

69220TX

56

Door Cabinet Assy.

1

69219TX

57

Handle & Latch

1

89927,89928

58

Rod & Nut Kit

1

24849

N/S

1/4-20 x 3/4 Bolt for Hinges

5

83339

N/S

1/4-20 Kep Nut for Hinges

5

83250

N/S = Not Shown

Содержание EC95

Страница 1: ...ULT FOR YOUR SAFETY FOLLOW THE INSTALLATION INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC TIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA To assure that satisfactory...

Страница 2: ...chance of drafts blowing smoke ashes or sparks out of the heater during refueling or ash removal 7 The heater should be located where a small supply of wood may be kept conveniently close but not wit...

Страница 3: ...EC95 3 FIGURE 3 MINIMUM CLEARANCES TO COMBUSTIBLES FIGURE 4 MINIMUM CLEARANCES TO COMBUSTIBLES SIDE SECTION VIEW PLAN SECTION VIEW...

Страница 4: ...btained from N F P A Inc Batterymarch Park Quincy MA 02269 The Chimney connector pipe from heater to chimney must be 6 inches in diameter and made from 24 gauge or heavier steel The length of the chim...

Страница 5: ...el supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold the chimney section Fasteners used to secure chimney sections shall not penetrate chimney flue l...

Страница 6: ...RICK ALL AROUND CHIMNEY CONNECTOR TO HEATER FIRE CLAY LINER 5 8 MIN WALL THICKNESS MIN 3 1 2 THICK BRICK MASONRY WALL MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 MINIMUM 12 IN TO COMBUSTIBLES PART A FIGUR...

Страница 7: ...RY CHIMNEY CONSTRUCTED TO NFPA 211 SHEET STEEL SUPPORTS 24 GAUGE MIN THICKNESS CHIMNEY CONNECTOR TO HEATER MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN MINIMUM...

Страница 8: ...O APPLIANCES OR HEATERS ARE CONNECTED TO THE SAME FLUE CAUTION THE HEATER MUST BE PLACED ON A LISTED FLOOR PROTECTOR AS NOTED IN THIS MANUAL IF THE FLOOR IS WOOD OR OTHER COMBUSTIBLE FLOORING IF CARPE...

Страница 9: ...obtain the fireplace items called for by figure 4 3 If the heater is to be installed on a combustible floor purchase a listed noncombustible floor protector as described in this manual and install it...

Страница 10: ...UILD A FIRE 1 Set the heater s thermostat control knob to the Hi position See figure 9 2 Open the feed door see figure 10 and lay paper and kindling on the rate in sufficient quantities to ensure good...

Страница 11: ...driven off and shortens the length of time the dense smoke is likely to deposit creosote on the chimney walls 5 DO NOT TAMPER WITH THE INTERNAL THERMOSTAT MECHANISM The thermostat has been designed a...

Страница 12: ...or several days when embedded in ashes VENTING SYSTEM CHIMNEY CONNECTOR AND CHIMNEY The venting system consists of the heater s chimney connector the pipe which connects the heater to the chimney and...

Страница 13: ...at has grown tall can affect the draft of a chimney that was previously trouble free and other factors The common unit used to measure draft is INCHES IF WATER To determine the draft of your chimney a...

Страница 14: ...ns as cleanly as possible Thus you should adjust the amount of wood you put in the heater to the outdoor temperature Placing excessive wood in the heater will cause excessive creosote formation in the...

Страница 15: ...omposition fire starters specifically designed for starting a fire The use of liquid fire starters can cause an explosion within the heater 14 Do use only a Listed High Temperature Type HT Factory bui...

Страница 16: ...t 11 Don t install this heater in a chimney flue that is used by another appliance 12 Don t neglect to clean and inspect your chimney regularly 13 Don t operate this heater with the doors open 14 Don...

Страница 17: ...EC95 17 FIGURE 12 ILLUSTRATION OF REPAIR PARTS SEE LEDGER ON NEXT PAGE FOR PART NAMES AND PART NUMBERS 47 58...

Страница 18: ...Ash Door 1 88057 18 Feed Door Assy 1 69229 19 Latch 1 25048 20 Liner Front 1 40412 22 Shield Door Ptd 1 24870 23 Pan Ash Welded 1 69206 24 Grate 2 40394 25 Angle Grate Support Assy 2 69205 26 Leveler...

Страница 19: ...k for Mechanical Engineers by Baumeister and Marks 6 K C and R factors are explained as follows A The K factor represents the thermal conductivity of a material and is the time rate of heat flow throu...

Страница 20: ...20 EC95...

Отзывы: