Ashley AW180 Скачать руководство пользователя страница 11

 

11

INSTALLATION INTO A MASONRY FIREPLACE

Ashley recommends the use of a full liner where a stainless steel rigid or 

fl

 exible linear pipe is routed from the insert outlet collar 

to the top of the chimney. 

Multiple installation methods may be available in your area. Check with local building of

fi

 cials for any permits required for 

installation of this unit and notify your insurance company before proceeding with installation. 

1) 

Clean the 

fi

 replace opening properly disposing of any ashes in a closed metal container. See Safety Instructions.

2) 

Install a continuous stainless steel chimney liner into the existing chimney. Follow liner manufacturer installation instructions.

• 

The liner must extend to the top of the existing chimney. 

• 

The interior diameter of the chimney 

fl

 ue must be identical to the stove smoke exhaust. 

• 

Use only listed chimney liners that meet UL1777 standards. 

3) 

Remove or lock the 

fi

 replace damper in the open position. Note: Masonry or damper plate may be removed to accommodate the 

chimney liner provided this does not weaken any structural components of the existing 

fi

 replace or chimney nor reduces protection 

of combustible materials required by national building codes. Consult with your local building or 

fi

 re authority before doing this.

WARNING: Any 

fi

 replace which has had parts removed or modi

fi

 ed to accommodate the installation of this appliance 

MUST have a warning plate permanently installed in a visible location stating that the 

fi

 replace is un

fi

 t for use with solid 

fuel. Permanently attach the warning plate to a visible location in the 

fi

 replace.

4) 

Uncrate the appliance, remove all packing materials, and any items stored in the 

fi

 rebox.

5) 

Position the appliance into the 

fi

 replace opening.

6) 

If necessary 1/4-20 leveling bolts can be inserted into the base and used as levelers for uneven 

fi

 replaces. 

7) 

Connect the chimney liner to the appliance using a stainless steel adapter and securing with a minimum of three (3) sheet metal 
screws. The liner MUST be attached with the male (or crimped) end of the adapter inside the 

fl

 ue collar of the appliance to allow 

condensation and/or creosote to drain back into the 

fi

 rebox.

8) 

 Assemble the facade. See 

“3.4 INSERT FIREPLACE FACADE ASSEMBLY”

 section for instruction on facade assembly 

and installation.

VENTILATION

Содержание AW180

Страница 1: ...IONS THIS MANUALWILLHELPYOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLEYOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE French version is available f...

Страница 2: ...655mm x 749mm x 685mm Combustion Chamber Width x Depth 12 7 x 11 9 322mm x 302mm Volume Cubic Feet 0 75 cubic feet Door Opening Width x Height 16 8 x 9 406mm x 228mm Pyroceramic Glass Door Viewing Wi...

Страница 3: ...of the three offered kits A Pedestal Kit SA180P B Leg Kit SA180L C Fireplace Insert SA180i Refer to the instructions found inside each kit for proper assembly A 7 16 socket wrench A 5 16 socket Best i...

Страница 4: ...otect the finish on your new stove FREESTANDING LEG ASSEMBLY 1 Unpack the kit and ensure all components are present Qty Description Part 4 Cast Iron Legs 40566 8 1 4 20 UNC Bolts 83339 8 Flat Washers...

Страница 5: ...set into its final position 2 Mark the location of the facade panels along the top of the stove with a pencil The mark will be used to realign the panels later 3 Slide stove out of fireplace far enou...

Страница 6: ...ur Side wall Paroi Lat rale Side wall Paroi Lat rale S de a a o at a e C B A Dimension Inch mm A Backwall to Stove 12 305 B Sidewall to Stove 12 305 C Sidewall to Flue 13 330 D Wall to Stove Angled In...

Страница 7: ...facturers of listed floor protectors include Imperial Metal Products and Hy C among others To calculate R Values for alternative methods see Alternate Floor Protector Calculation Methods in the back o...

Страница 8: ...2 To attach the leg model use two 3 8 16 UNC bolts through the floor The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a serrated or star wa...

Страница 9: ...arrier and tight fitting windows and or has any powered devices that exhaust house air 5 There is excessive condensation on windows in the winter 6 A ventilation system is installed in the house If an...

Страница 10: ...ote that it is the chimney and not the stove which creates the draft effect your stove s performance is directly dependent on an adequate draft from your chimney Do not connect this unit to a chimney...

Страница 11: ...any structural components of the existing fireplace or chimney nor reduces protection of combustible materials required by national building codes Consult with your local building or fire authority b...

Страница 12: ...essional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a...

Страница 13: ...nd a minimum 24 gauge ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insul...

Страница 14: ...d 211 To insure a good draft the total length of the stove pipe should never exceed 8 to 10 2 4m to 3 04 m Except for cases of vertical installation cathedral roof style where the smoke exhaust system...

Страница 15: ...nufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to the st...

Страница 16: ...iencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut hardwoods DO NOT BURN Burning these materials may result in r...

Страница 17: ...aper and kindling wood it is recommended that you warm up the chimney This is done in order to avoid back draft problems often due to negative pressure in the house If such is the case open a window s...

Страница 18: ...chimney as lost energy Therefore efficiency calculated using the lower heating value of wood will be higher than efficiency calculated using the higher heating value In the United States all woodstov...

Страница 19: ...ol then inspect the chimney for damage If no damage results perform a chimney cleaning to ensure there is no more creosote deposits remaining in the chimney ASH DISPOSAL Whenever ashes get 3 to 4 inch...

Страница 20: ...oove apply a high temperature silicone sold for this purpose and install the new gasket You may light up your stove again approximately 24 hours after having completed this operation This unit s door...

Страница 21: ...ossible Remedies Unplug blower first if equipped Cool exhaust flue gasses Use double or triple wall external chimney Burning unseasoned wet wood Use dry seasoned hardwood Smoke rolls out when feed or...

Страница 22: ...rick 4 5 X 7 5 X 1 25 2 18 891783 Firebrick 3 X 4 1 2 3 19 26706 Right Brick Retainer 1 20 26705 Left Brick Retainer 1 21 610073 Rear Access Panel 1 22 26703 Window Clamp 4 23 69953 Door Assembly 1 24...

Страница 23: ...23 29 28 27 32 31 30 26 25 33 13 29 12 8 7 18 16 20 19 17 3 23 6 9 22 10 2 11 34 1 15 21 24 14 4 5 WIRING SCHEMATIC...

Страница 24: ...Qty 35 26731 MAIN WRAP 1 36 26732 CENTER SUPPORT 1 37 26733 BASE PLATE 1 38 852049 Ashley LOGO 1 39 26730 BACKING PLATE 1 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL MANUF...

Страница 25: ...given with a required thickness T in inches R 1 k x T c C factor is given R 1 C 2 Determine the R value of proposed alternate floor protector a Use formulas in step 1 above to calculate R value of pro...

Страница 26: ...hed to the stove When ordering repair parts always give the following information as shown in this list HOW TO ORDER REPAIR PARTS 1 The part number AW180 2 The part description _______________________...

Страница 27: ...______ Reason for Purchase Alternative Heat Main Heat Source Decoration Cost Other _________________________ What was the determining factor for purchasing your new appliance _______ I have read the o...

Страница 28: ...CUT HERE CUT HERE Fold Here Fold Here U S Stove 227 Industrial Park Road South Pittsburg TN 37380 USA Fold Here PLACE STAMP HERE...

Отзывы: