14
© 2021 United States Stove Company
1. Your stove is equipped with a high temperature
thermodisc. This unit has a manual reset
thermodisc. This safety switch has two functions.
A. To recognize an overheat situation in the stove
and shut down the fuel feed or auger system.
B.
In case of a malfunctioning convection
blower, the high-temperature thermodisc will
automatically shut down the auger, preventing
the stove from overheating.
NOTE: On some units, once tripped, like a circuit
breaker, the reset button will have to be pushed
before restarting your stove. On other units the
thermodisc has no reset button and will reset
itself once the stove has cooled. The manufacturer
recommends that you call customer service if this
occurs as this may indicate a more serious problem.
A service call may be required.
2.
If the combustion blower fails, an air pressure
switch will automatically shut down the auger.
NOTE: Opening the stove door for more than
30 seconds during operation will cause enough
pressure change to activate the air switch, shutting
the fuel feed off. The stove will shut down and show
“E2” on the two digit display. The stove has to fully
shut down before restarting.
OPTIMAL OPERATION
This pellet stove has been certified by the US EPA
to meet strict 2020 guidelines. To Insure this unit
produces the optimal minimal emissions, it is
critical to follow the following guidelines.To achieve
a “high burn” your stove should be set on setting 5
with the damper fully open.To achieve a “medium
burn” your stove should be set on setting 1 with the
damper fully closed.To achieve a “low burn” your
stove should be set on setting 1 with the damper
open.Settings 2,3 & 4 will give you a higher heat
output above medium and the damper should be
open for these settings. If the door is opened while
the stove is in operation it must be closed within
30 seconds or the stove will shut down. If the stove
shuts down push the “On/Off” button to re-start
your stove. The stove will have to fully shut down
and turn off before you will be able to restart the
stove
INTERIOR CHAMBERS
• Burn Pot: Periodically remove and clean the burn
pot and the area inside the burn pot housing. In
particular, it is advisable to clean out the holes in
the burn pot to remove any build up that may
prevent air from moving through the burn pot
freely.
•
Heat Exchanger: There is a clean out plate on
both sides of the heat exchanger that need to be
removed to clean fly ash out of the heat exchanger.
The cleanouts are located inside the cabinet doors,
on the lower front corners of the heat exchanger.
To access these clean outs, you must remove both
side panels. The clean outs are secured to the
firebox with (2) 5/16” screws. Remove the clean
outs and vacuum out any accumulated ash. This
should be done at least once per month or more
frequently if large amounts of ash are noticed
while cleaning or if the stove does not seem to be
burning properly.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac
is designed for ash removal. Some regular vacuum
cleaner (i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
WARNING:
FAILURE TO PROPERLY MAINTENANCE
THE CLEAN OUTS WILL RESULT IN POOR
PERFORMANCE OF THIS STOVE.
Clean-Out
Plate
Clean-Out
Plate
OPERATION INSTRUCTIONS