HOW YOUR HEATER WORKS

Your pellet heater operates on a timer based auger 

fuel feed system, that is controlled by a digital circuit 

board. The fuel is delivered from the auger into a 

burn pot, which is the vessel where the combustion 

process takes place. Based upon the heat ranges 

(1-5),  the  heater  will  feed  the  appropriate  amount 

of fuel to reach a set temperature range. Note that 

the amount of heat produced by the heater is 

proportional to the rate of the fuel that is burned. 

Your heater is equipped with an automatic ignition 

system  that  should  ignite  the  fuel  within  5-10 

minutes  from  pressing  the  ON  button.  As  pellets 

fall into the burn pot and ignite, outside air is drawn 

in to feed the fire by a combustion blower. The post 

combustion gases are then pulled through the heat 

exchanger as they are traveling out the exhaust. As 

the heater warms up, room air is circulated around 

the heat exchanger by means of a room air blower, 

distributing warm air into the room. Because a 

forced draft pressure is required for the combustion 

process inside your heater, it is extremely important 

that the exhaust system be properly maintained. 

And,  that  when  operating  your  heater,  you  make 

sure that the viewing and combustion doors are 

properly closed and/or sealed.

CONTROL PANEL OVERVIEW

Turning the heater ON/OFF, as well as adjustments 

for the fuel feed rate is performed by pressing the 

appropriate button(s) on the control panel which is 

located on the front, lower left-hand corner of your 

heater.

ON/OFF

• 

Pressing the “ON” button on the control panel will 

begin the start-up sequence for the heater. Fuel 

will begin to feed through the auger feed system 

then ignite after approx. 5 minutes.

• 

Pressing  the  “OFF”  button  on  the  control  panel 

will  cause  the  heater  to  enter  its  shut-down 

sequence. The fuel feed system will stop pulling 

fuel from the hopper and, once the fire goes out 

and the heater cools down, the fans will stop 

running.

HEAT RANGE

• 

Pressing  the  “Heat  Range”  arrows,  up  or  down, 

will adjust the amount of fuel being delivered to 

the burn pot.

• 

The  exhaust  blower  will  start.  Note  that  this 

appliance pulses the exhaust blower in order to 

achieve the proper air to fuel ratio, and to also aid 

in the cleaning of the burn pot.

•  Once the heater reaches a set temperature, the 

room fan will come on.

LIGHT (LED) INDICATORS

• 

Heat  Range  LED  -  displays  the  selected  heat 

setting.  Number  “1”  LED  lights  to  display  that 

there is power to unit even if the heater is off.

• 

Door Sw LED - lights when front viewing door is 

opened or if the hopper lid is raised.

• 

Press Sw LED - lights if pressure is lost inside the 

combustion chamber (see “Errors”).

• 

E LED - Operational Error (see “Errors”).

• 

ON  LED  -  Flashes  in  start-up  mode.  On  solid 

during Run mode

• 

OFF LED - Flashes during shut down mode.

ATTENTION:

THIS HEATER IS DESIGNED AND APPROVED 

FOR PREMIUM HARDWOOD PELLET FUEL 

ONLY. ANY OTHER TYPE OF FUEL BURNED 

IN THIS HEATER WILL VOID THE WARRANTY 

AND SAFETY LISTING.

This heater is designed to burn only PFI Premium 

grade pellets. This appliance can also burn pellets 

rated as standard after May 16, 2015. DO NOT BURN:
1. 

Garbage;

2.  Lawn clippings or yard waste;

3. 

Materials containing rubber, including tires;

4.  Materials containing plastic;

5.  Waste petroleum products, paints or paint 

thinners, or asphalt products;

OPERATION INSTRUCTIONS

NEVER OPERATE THIS PRODUCT WHILE UNATTENDED

Содержание AP5000

Страница 1: ...lding or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place F...

Страница 2: ...owest setting 35 hours Hopper Capacity 28 lbs Electrical Specifications Electrical Rating 110 120 volt 60Hz 3 0 Amp Watts operational 175 approximately Watts igniter running 425 approximately Dimensions Height X Width X Depth 27 685 7 mm X 36 914 4 mm X 12 43 315 77 mm Depth with Mounting Wall Bracket Approx 14 27 362 4 mm For Customer Service please call 1 800 750 2723 Ext 5050 or Text to 423 301...

Страница 3: ... Brand___________________________________ If no Date of inspection of existing venting system _______________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this manual...

Страница 4: ... FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT ATTENTION THIS HEATER MUST BE INSTALLED ON AN EXTERIOR WALL TO THE OUTSIDE A WORKING SMOKE DETECTOR MUST BE INSTALLED IN THE SAME ROOM AS THIS PRODUCT ATTENTION THE HEATER WILL NOT OPERATE DURING A POWER OUTAGE IF A POWER OUTAGE DOES OCCUR CHECK THE HEATER FOR SMOKE SPILLAGE AND OPEN A WINDOW IF ANY SMOKE SPILLS INTO THE ROOM NEVER BLOCK FREE...

Страница 5: ...tute NFI certified specialist This heater must be installed on an exterior wall to allow exhaust venting to meet the minimum required clearances Once the desired location is selected and before cutting a hole check the outside of the structure for anything obstructing clearances to the exhaust vent Also clear away leaves shrubs bushes or trees that may be around the exhaust outlet CAUTION BEFORE I...

Страница 6: ...s of the mobile home with 8 GA copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding When moving your mobile home the heater must be removed while the mobile home is being relocated After relocation heater may be reinstalled and securely fastened Check with your local building officials as other codes may apply GENERAL INSTALLATION NOTES Do not in...

Страница 7: ...n the studs Use a pencil to mark the pilot hole locations and intake exhaust through hole then remove the mounting plate from the wall 3 Drill the four pilot holes to a depth of 2 75 mm using a 5 32 3 96 mm diameter drill bit 4 Find the center of the through hole for the wall thimble and drill a pilot hole all the way through the wall to the exterior with an installer bit Use this hole as a center...

Страница 8: ...nting bracket secured to the wall the heating unit can hung on the bracket 3 Align intake with the hole in the wall mounting bracketandthimble andcarefullyinsertheating unit Tilt the top of the heating unit towards the wall and lower onto the wall mounting bracket making sure that the right and left bracket mounted to the unit hooks over the top of the wall mounting bracket Allow the Heating Unit ...

Страница 9: ... field Assemble the desired combination of Pipe Sections and Elbows to the Appliance Adaptor Notes Twist lock procedure Line up locking lugs on male and female ends of pipe sections Insert the male end of pipe into the female end until the locking lugs are covered Twist the female end clockwise an eighth of a turn to lock sections together Three screws are required to secure the joint ensure they ...

Страница 10: ...l will begin the start up sequence for the heater Fuel will begin to feed through the auger feed system then ignite after approx 5 minutes Pressing the OFF button on the control panel will cause the heater to enter its shut down sequence The fuel feed system will stop pulling fuel from the hopper and once the fire goes out and the heater cools down the fans will stop running HEAT RANGE Pressing th...

Страница 11: ...f fuel approximately 4 5 lbs or about the amount to fill a 2 lb coffee can Operate the appliance on the 3 or 4 heat setting for approximately 30 minutes to an hour There will probably be a small amount of smoke or fumes irradiating from the appliance during this process Follow the Start Up procedure below to begin your burn START UP PROCEDURE WARNING DO NOT USE CHEMICALS OR FLUIDS TO START THE FIR...

Страница 12: ...normally If the fire has gone out you will have to press the OFF button and then the ON button again to begin a new start up sequence 2 If the heater has cooled off it will reset to its OFF condition At this point you may press the ON button and the unit will begin a new start up sequence Make it a habit to empty the burn pot in these situations NOTE The unit will also shut down in the event of an...

Страница 13: ...om moving through the burn pot freely As good practice you should remove and clean the burn pot each time you restart the heater weekly or as needed as this ensures that the best efficiency is achieved If a vacuum is used to clean your heater we suggest using a vacuum designed for ash removal Some regular vacuum cleaner i e shop vacs may leak ash into the room ASH REMOVAL Remove the ashes periodic...

Страница 14: ...g We recommend using a high quality glass cleaner Should a buildup of creosote or carbon accumulate you may wish to use 000 steel wool and water to clean the glass DO NOT use abrasive cleaners DO NOT perform the cleaning while the glass is HOT In the event you need to replace the glass Do not attempt to operate the unit with broken glass Replacement glass may be purchased from your U S Stove Pelle...

Страница 15: ...id your warranty Unplug your heater s electrical cord prior to removing the back panel or opening the exhaust system for any inspection cleaning or maintenance work Never perform any inspections cleaning or maintenance on a hot heater Do not operate heater with broken glass leakage of flue gas may result Daily Weekly Monthly or as needed Burn Pot Stirred Empty Combustion Chamber Brushed Ashes Chec...

Страница 16: ... start a fire when the ON button is pushed Turn the heater OFF Clear the unburnt fuel from the burn pot and try again Check the pellet quality Replace if moist wet or dirty Loss of draft pressure Make sure that the combustion door is closed and sealed properly If not adjust door catch and or replace door gaskets Check that the exhaust is clear of any obstructions Clean as needed Check that the aut...

Страница 17: ...nections and fuse If all wires are properly connected you have a bad control board Control board not sending power to pressure switch There should be a 5 volt current approximately going to the air switch after the stove has been on for 30 seconds Pressure switch has failed To test the pressure switch you will need to disconnect the air hose from the body of the stove With the other end still atta...

Страница 18: ...s unit That information can be found on the certification label attached to the back of the unit Other information that may be needed would be the part number and part description of the item s in question Part numbers and descriptions can be found in the Repair Parts section of this manual Once this information has been gathered you can contact customer service by phone 1 800 750 2723 Ext 5051 or...

Страница 19: ... 2021 United States Stove Company 19 REPAIR PARTS 1 5 7 8 9 11 10 20 21 19 3 2 4 27 28 29 31 30 32 33 34 6 17 15 22 23 24 25 26 16 13 14 18 12 ...

Страница 20: ... 1 18 26187 Right Side Exhaust Panel 1 19 88182 Exhaust Blower Gasket 1 20 80573 Exhaust 70 CFM Blower 1 21 26185 Exhaust Panel Top Bottom And Back Side 1 22 26231 RTD Mounting Bracket 1 23 80531 Platinum RTD 1 24 88179 LT Chamber Insulation 1 25 88178 Wrapped Chamber Insulation 1 26 26360 Exhaust Intake Beauty ring 1 27 26196 Feed Tube Cover 2 28 26195 Ignitor Cover 1 29 88180 Chamber Insulation ...

Страница 21: ... 1 3 893307 Main Left Front Door 1 4 893310 Door Spacer 1 5 893311 Exhaust Louver Weldment 1 6 88342 Left Front Door Insulation 1 7 893313 Main Door Back Panel 1 8 892174 Door Plunger 1 5 4 3 2 1 6 7 1 2 8 7 3 4 5 6 REPAIR PARTS IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ASHLEY PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM ASHLEY USE OF THIRD PARTY COMPONENTS WILL VOID ...

Страница 22: ...7 Date ______________________ Engineer Name ________________________________ License No _____________________________________ Company ______________________________________ Telephone No __________________________________ Stove Inspected Chimney Swept Items Replaced ________________________________ Service 02 Date ______________________ Engineer Name ________________________________ License No ____...

Страница 23: ...icles Remplacé _____________________________ Service de 07 Date _____________________ Nom de l ingénieur ____________________________ N de licence __________________________________ Compagnie ___________________________________ N de téléphone _______________________________ Poêle Inspecté Cheminée balayée Articles Remplacé _____________________________ Service de 02 Date _____________________ Nom ...

Страница 24: ...etoise de porte 1 5 893311 Soudure des volets d échappement 1 6 88342 Isolation de la porte avant gauche 1 7 893313 Panneau arrière de la porte principale 1 8 892174 Piston de porte 1 5 4 3 2 1 6 7 1 2 8 7 3 4 5 6 AFIN DE CONSERVER LE BÉNÉFICE DE LA GARANTIE LES COMPOSANTS DOIVENT ÊTRE REMPLACÉS PAR DES PIÈCES D ORIGINE DES FABRICANTS ACHETÉS CHEZ VOTRE REVENDEUR OU DIRECTEMENT AUPRÈS DU FABRICANT...

Страница 25: ...bustion Porte Propre 1 14 26175 Chambre Propre Porte De Combustion 1 15 892397 Porte De La Chambre De Combustion 1 16 88033 Joint De Chambre De Combustion 1 17 891748 Soudure De Pot De Combustion 1 18 26187 Panneau D échappement Côté Droit 1 Clé Partie La Description Qté 19 88182 Joint Principal De Soufflante D échappement 1 20 80573 Échappement Ventilateur De 70 CFM 1 21 26185 Panneau D échappeme...

Страница 26: ... 2021 United States Stove Company 19 1 5 7 8 9 11 10 20 21 19 3 2 4 27 28 29 31 30 32 33 34 6 17 15 22 23 24 25 26 16 13 14 18 12 PIÈCES DE RECHANGE ...

Страница 27: ...GE NOIR MOTEUR D ENTRAÎNEMENT DE VIS SANS FIN CÂBLE DE COMMUNICATION PRISE MOLEX VERS LA CARTE DE C I CARTE DE C I PRINCIPALE PRESSOSTAT NOIR NOIR ALLUMEUR VENTILATEUR DE DISTRIBUTION VENTILATEUR D ÉVACUATION CONTACTEUR DE TRÉMIE CONTACTEUR DE PORTE DTR D AIR AMBIANT DTR D ÉVACUATION NOIR CORRECTE MAL ASSUREZ VOUS QUE LES FILS SONT CONNECTÉS AUX DEUX BROCHES INFÉRIEURES DE L INTERRUPTEUR DE LA TRÉ...

Страница 28: ...ctrique du ventilateur de combustion Ce doit être la tension nominale Si l alimentation électrique est bonne c est le ventilateur qui est défectueux Le tableau de commande n envoie pas le courant au ventilateur de combustion Si l alimentation électrique n arrive pas au ventilateur de combustion vérifiez toutes les connexions des fils électriques et le fusible Si tous les fils sont bien connectés c...

Страница 29: ...a trémie soient complètement fermés Le système de vis sans fin est bloqué ou il y a un pont de combustible dans la trémie ce qui l empêche de s écouler dans le système d alimentation à vis sans fin PROBLÈME CAUSE L allumeur automatique n allume pas le combustible dans le pot de combustion L appareil de chauffage n allume pas le feu lorsqu on appuie sur le bouton ON Mettez l appareil en position OF...

Страница 30: ...nuel Une fois ces informations recueillies vous pouvez contacter le service client par téléphone au 1 800 750 2723 poste 5051 ou par e mail à parts usstove com Informations sur le modèle Numéro de modèle Numéro de série Pour l assistance sur les pièces appelez le 800 750 2723 poste 5051 ou par courriel parts usstove com ENTRETIEN ANNUEL Il est recommander de faire entretenir et nettoyer l appareil...

Страница 31: ...ettoyant vitre de haute qualité Si une accumulation de créosote ou de carbone s accumule vous pouvez utiliser 000 laines d acier et de l eau pour nettoyer le verre NE PAS utiliser de nettoyants abrasifs NE PAS effectuer le nettoyage pendant que le verre est CHAUD Dans le cas où vous devez remplacer le verre Ne tentez pas de faire fonctionner l appareil avec du verre cassé Le verre de rechange peut...

Страница 32: ...itre de bonne pratique vous devez sortir et nettoyer le pot de combustion chaque fois que vous redémarrez l appareil de chauffage chaque semaine ou selon les besoins pour obtenir une efficacité maximale Si vous utilisez un aspirateur pour nettoyer l appareil de chauffage nous vous suggérons d utiliser un aspirateur conçu pour l enlèvement des cendres Certains aspirateurs normaux aspirateurs d atel...

Страница 33: ... la trémie est inférieure à 7 6 cm 3 pouces L appareil de chauffage ne fonctionne pas en cas de coupure de courant L une des actions suivantes se déroule si l appareil était allumé lorsque la panne de courant s est produite 1 Si l appareil est encore chaud il reprendra l alimentation en combustible et continuera à fonctionner normalement Si le feu s est éteint vous devrez appuyer sur le bouton OFF...

Страница 34: ...tite quantité de combustible environ 4 5 lbs ou à peu près le contenu d une boîte de conserve de 1 kg Faites fonctionner l appareil sur le réglage de température 3 ou 4 pendant environ 30 minutes à une heure L appareil émettra probablement une petite quantité de fumées ou de vapeurs pendant cette opération Suivez la procédure de démarrage ci dessous pour commencer la combustion PROCÉDURE DE DÉMARR...

Страница 35: ... de commande qui se trouve dans le coin inférieur gauche à l avant de l appareil ALLUMAGE EXTINCTION L appui sur le bouton ON du tableau de commande déclenche la séquence de démarrage de l appareil Le carburant est envoyé dans l appareil par le système d alimentation à vis sans fin puis s enflamme au bout de 5 minutes environ L appui sur le bouton OFF du tableau de commande déclenche la séquence d...

Страница 36: ...aites pivoter l extrémité femelle dans le sens horaire d un huitième de tour pour verrouiller les sections ensemble Trois vis sont nécessaire pour immobiliser le joint vérifiez qu elles ne percent pas la paroi interne du conduit d évent Les sections horizontales du conduit d évent doivent être soutenues pour les empêcher de se tasser Les sections horizontales doivent être soutenues au moins tous l...

Страница 37: ...upport de fixation murale Laissez l appareil de chauffage de pivoter vers le bas et se positionner parallèlement au support de fixation murale Soulevez l appareil les crochets inférieurs viennent s engager dans le support 4 Une fois que l appareil est solidement accroché au support mural il faut serrer les deux boulons de 7 16 po sur la partie inférieure du support afin de verrouiller l appareil a...

Страница 38: ...rous à une profondeur de 75 mm 2 po avec un foret de 3 96 mm 5 32 po de diamètre 4 Trouvez le centre du trou de passage du coupe feu mural et percez un avant trou dans toute l épaisseur du mur jusqu à l extérieur avec une mèche d installation Utilisez ce trou comme point central pour découper l orifice dans le mur extérieur 5 Découpez soigneusement l orifice d évacuation d admission dans toute l é...

Страница 39: ...toile pour attaquer la peinture ou le revêtement protecteur afin d assurer une bonne mise à la masse En cas de déplacement de la maison mobile toutes les sorties extérieures doivent être déposées pendant le déplacement Après le déplacement l appareil de chauffage peut être réinstallé et solidement fixé Vérifiez auprès de votre municipalité si d autres réglementations sont applicables REMARQUES GÉN...

Страница 40: ...tute NFI Ce radiateur doit être installé sur un mur extérieur pour permettre à la ventilation d évacuation de respecter les dégagements minimaux requis Une fois que l emplacement souhaité est sélectionné et avant de couper un trou vérifiez l extérieur de la structure pour tout élément obstruant les dégagements de la sortie d échappement Éliminez également les feuilles les arbustes buissons ou les ...

Страница 41: ...EST EN MARCHE NE PAS RACCORDER OU UTILISER EN CONJONCTION AVEC TOUT CONDUIT DE DISTRIBUTION D AIR SAUF SAUF APPROUVÉ SPÉCIFIQUEMENT POUR DE TELLES INSTALLATIONS NE PAS RACCORDER CET APPAREIL À UN FUMÉE DE CHEMINÉE SERVANT UN AUTRE APPAREIL N INSTALLEZ PAS D AMORTISSEUR DE FUMÉE DANS LE SYSTÈME D ÉVACUATION D ÉCHAPPEMENT DE CET APPAREIL ATTENTION CET APPAREIL DE CHAUFFAGE DOIT ÊTRE INSTALLÉ SUR UN ...

Страница 42: ...non date d inspection du système de ventilation existant _________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et des joints de porte Confirmer les dégagements aux combustibles selon les instructions d inst...

Страница 43: ...n du poêle à bois Ashley AP5000 Cet appareil de chauffage respecte les limites d émission de bois des appareils de chauffage au bois vendues après le 15 mai 2020 par l Agence de protection de l environnement des États Unis pour la protection de l environnement Dans des conditions de test spécifiques il a été démontré que cet appareil de chauffage fournissait de la chaleur à des débits allant de 8 ...

Страница 44: ...aître les permis les restrictions et les exigences d installation dans votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages matériels des blessures corporelles ou même la mort Une installation incorrecte pourrait annuler ...

Отзывы: