© 2021 United States Stove Company
7
PRODUCT FEATURES
On/Off Switch
Door
Off/Pilot/On Knob
Hi/Lo Knob
Piezo
Gas Pressures
Natural
Propane
(LP)
Regulator Pressure
3.5” w.c.
10.0” w.c.
Pilot Regulator
3.5” w.c.
n/a
Max. Gas Inlet
Pressure
10.5” w.c.
13.0” w.c.
Min. Gas Inlet
Pressure
5.0" w.c.
11.0" w.c.
Fuel Control
Max. Input
BTU/h
Min. Input
BTU/h
Nat. Millivolt
32,000
23,000
LP Millivolt
32,000
23,000
WARNING:
THIS APPLIANCE IS EQUIPPED FOR (NATURAL
OR PROPANE) GAS. FIELD CONVERSION IS
NOT PERMITTED.
NOTE: An external regulator is required to reduce
supply pressure to a maximum of 10.5” w.c. on
Natural Gas systems operating at higher pressure.
NOTE: An external regulator is required to reduce
supply pressure to a maximum of 13.0” w.c. for LP
systems.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the
use of matches.
Millivolt control has four (4) positions:
OFF
All gas to the burner is shut off at the
valve.
IGN
Valve position to light/maintain a
standing pilot.
ON
Valve position to turn burners on/off.
LOW/
HI
Variable position to control flame
height (heat output). Both front and
rear burners are in operation to provide
realistic glow and yellow flame.
PILOT /ODS
The gas log heater is fitted with a specially designed
safety pilot (ODS assembly) light which senses the
amount of oxygen available in the room and shuts
the gas log heater off if the oxygen level begins to
drop below a satisfactory level. The pilot can only be
relit when adequate fresh air is available.
DIMENSIONS
A
B
C
A
B
C
A
B
C
A
26” (660mm)
B
16” (406mm)
C
29” (737mm)
Содержание AGC500VF