© 2021 United States Stove Company
5
MANUFACTURER REQUIREMENTS
GAS EQUIPMENT VENTING SYSTEM
PROVIDED
When the manufacturer of Product Approved side
wall horizontally vented gas equipment provides
a venting system design or venting system
components with the equipment, the instructions
provided by the manufacturer for installation of the
equipment and the venting system shall include:
•
Detailed instructions for the installation of the
venting system design or the venting system
components; and
•
A complete parts list for the venting system
design or venting system.
GAS EQUIPMENT VENTING SYSTEM NOT
PROVIDED
When the manufacturer of a Product Approved
side wall horizontally vented gas fueled equipment
does not provide the parts for venting the flue
gases, but identifies “special venting systems”, the
following requirements shall be satisfied by the
manufacturer:
•
The referenced “special venting system”
instructions shall be included with the appliance
or equipment installation instructions; and
•
The “special venting systems” shall be Product
Approved by the Board, and the instructions for
that system shall include a parts list and detailed
installation instructions.
A copy of all installation instructions for all Product
Approved side wall horizontally vented gas fueled
equipment, all venting instructions, all parts lists
for venting instructions, and/or all venting design
instructions shall remain with the appliance or
equipment at the completion of the installation.
1.
Due to high temperatures, the appliance should
be located out of traffic and away from furniture
and draperies.
2. Children and adults should be alerted to the
hazard of high surface temperature and should
stay away to avoid burns or clothing ignition.
3. Young children should be carefully supervised
when they are in the same room with the
appliance.
4.
Do not place clothing or other flammable
material on or near the appliance.
5.
Any safety screen or guard removed for
servicing an appliance, must be replaced prior
to operating the heater.
6.
Installation and repair should be done by a
qualified service person.
7. To prevent malfunction and/or sooting, an
unvented gas heater should be cleaned before
use and at least annually by a professional
service person. More frequent cleaning may be
required due to excessive lint from carpeting,
bedding material, etc. It is imperative that
control compartments, burners and circulating
air passageways be kept clean.
8.
CARBON MONOXIDE POISONING: Early signs
of carbon monoxide poisoning are similar
to the flu with headaches, dizziness and/or
nausea. If you have these signs, obtain fresh air
immediately. Have the heater serviced as it may
not be operating properly.
9. The installation must conform with local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.l/NFPA54.
10. This unit complies with the latest edition of
ANSI Z21.11.2, Unvented Heaters.
11.
Do not install heater in a bathroom or bedroom
unless approved for bedroom use.
12.
Correct installation of the ceramic fiber logs,
proper location of the heater, and annual
cleaning are necessary to avoid potential
problems with sooting. Sooting, resulting
from improper installation or operation, can
settle on surfaces outside the fireplace. See log
placement instructions for proper installation.
13.
Avoid any drafts that alter burner flame patterns.
Do not allow fans to blow directly into fireplace.
Do not place a blower inside burn area of firebox.
Ceiling fans may create drafts that alter burner
flame patterns. Sooting and improper burning
will occur.
SAFETY INFORMATION
Содержание AGC500VF
Страница 24: ...24 2021 United States Stove Company NOTES ...