background image

18

© 2021 United States Stove Company

MANUAL LIGHTING INSTRUCTIONS

1. 

Open stove door. Remove any items necessary 

for easy access to the pilot (for example: logs, 

screens, etc.).

2.  Follow appropriate lighting instructions found 

previously. Instead of pushing and releasing the 

piezo button, light a match and hold the flame 

to the end of the pilot and ignite the pilot.

3. 

After control knob has been released and pilot 

stays lit, reinstall any items that were removed 

for pilot access.

4. 

Call  a  qualified  service  technician  for  repair  or 

replacement of the piezo ignitor.

CLEANING AND SERVICING

WARNING:

TURN OFF THE HEATER AND ALLOW TO 

COOL BEFORE CLEANING. DISCONNECT THE 

ELECTRICAL POWER BEFORE CLEANING OR 

SERVICING.

Annual  inspection  and  cleaning  by  your  dealer  or 

qualified  service  technician  is  recommended  to 

prevent malfunction and/or sooting. Remove logs, 

handle carefully by holding gently at each end. 

Gloves are recommended to prevent skin irritation 

from ceramic fibers. If skin becomes irritated, wash 

gently  with  soap  and  water.  Refer  to  manual  for 

correct log placement.

Periodic Cleaning

 - See parts diagram for location 

of items discussed below.
• 

Do not use cleaning fluid to clean logs or any part 

of the heater.

• 

Brush  logs  with  a  soft  bristle  brush  or  vacuum 

with a brush attachment.

•  Vacuum loose particles and dust from the front 

and rear burners, control, piezo covers and grate 

weldment.

• 

Inspect  and  clean  the  burner  air  intake  holes. 

Remove lint or particles with a vacuum, brush, or 

some pipe cleaners. Failure to keep air intake holes 

clean will result in sooting and poor combustion.

•  The external case should be dusted and wiped 

with a moist cloth.

Annual Cleaning/Inspection 

-  Refer  to  parts 

diagram for location of items.
• 

Inspect and clean burner air intake holes. Remove 

lint or particles with a vacuum, brush or some 

pipe cleaners. Failure to keep the air intake holes 

clean will result in sooting and poor combustion.

• 

Inspect and clean all burner ports.

• 

Inspect ODS pilot for operation and accumulation 

of lint at air intake holes.

• 

Verify flame pattern and log placement for proper 

operation.

•  Verify smooth and responsive ignition of main 

burner and rear burner.

For Parts Assistance Call: 800-750-2723 Ext 5051 or Email: [email protected]

The  information  in  this  owner’s  manual  is  specific  to  your  unit.  When  ordering  replacement  parts  the 

information in this manual will help to ensure the correct items are ordered. Before contacting customer 

service write down the model number and the serial number of this unit. That information can be found on 

the certification label attached to the back of the unit. Other information that may be needed would be the 

part number and part description of the item(s) in question. Part numbers and descriptions can be found 

in the “Repair Parts” section of this manual. Once this information has been gathered you can contact 

customer service by phone 1-800-750-2723 Ext 5051 or Email  [email protected].

Model Information

Model Number
Serial Number

HOW TO ORDER REPAIR PARTS

OPERATION

Содержание AGC500VF

Страница 1: ...erence Please read this manual BEFORE installing and operating this unit Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neigh...

Страница 2: ...EATER OR ITS CONTROLS CAN CAUSE DEATH OR SERIOUS INJURY READ AND FOLLOW INSTRUCTIONS AND PRECAUTIONS IN USER S INFORMATION MANUAL PROVIDED WITH THIS HEATER DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE STOVE AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS DO NOT USE A BLOWER INSERT HEAT EXCHANGER INSERT OR OTHER ACCESSORY NOT APPROVED FOR USE WITH THIS HEATER WHERE APPLICABLE IMPORTANT READ THIS O...

Страница 3: ...Brand___________________________________ If no Date of inspection of existing venting system _______________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this manual ...

Страница 4: ...sed professionals for the installation of hard wired carbon monoxide detectors In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level In the event that the requirements of this subdivision can not be met at the time of ...

Страница 5: ...tay away to avoid burns or clothing ignition 3 Young children should be carefully supervised when they are in the same room with the appliance 4 Do not place clothing or other flammable material on or near the appliance 5 Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater 6 Installation and repair should be done by a qualified service perso...

Страница 6: ...tain oils films or bonding agents These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance possibly causing headaches or eye or lung irritation This is a normal and temporary occurrence The initial break in operation should last two to three hours with the burner at the highest setting Provide maximum ventilation...

Страница 7: ...d to reduce supply pressure to a maximum of 13 0 w c for LP systems IGNITION CONTROLS Piezo ignitor allows ignition of the pilot without the use of matches Millivolt control has four 4 positions OFF All gas to the burner is shut off at the valve IGN Valve position to light maintain a standing pilot ON Valve position to turn burners on off LOW HI Variable position to control flame height heat outpu...

Страница 8: ... THE GAS TECHNICIAN WILL NEED FOR INSTALLATION You must have the following items available before proceeding with installation External regulator for Propane LPG or high pressure natural gas 1 to 2 psi system Piping which complies with local codes Sediment trap recommended Pipe wrench Pipe sealant approved for use with propane LPG resistant to sulfur compounds Manual shutoff valve Tee joint Screwd...

Страница 9: ...TALLED ON A CARPET TILE OR OTHER COMBUSTIBLE MATERIAL THE APPLIANCE SHALL BE INSTALLED ON A NONCOMBUSTIBLE MATERIAL PANEL EXTENDING THE FULL WIDTH AND DEPTH OF THE APPLIANCE D Minimum to Side Wall E Minimum to Side Wall A Front View Ceiling Mantel Side Wall F Minimum 36 in Front C B Side View Ceiling G G Corner Installation D Minimum to Either Side Wall F Minimum Wall Installation A Min Ceiling Fr...

Страница 10: ...ION CAUTION THE APPLIANCE IS VERY HEAVY THE ASSISTANCE FROM A SECOND PERSON IS STRONGLY SUGGESTED PLEASE USE PROPER LIFTING TECHNIQUE WHEN POSITIONING THE APPLIANCE FOR ASSEMBLY AND INSTALLATION 1 Remove the two 2 straps and open the wrapping Slide the bag to the bottom of the unit ON OFF LOGS Pallet Wrapping Straps 2 Lift up on the ash lip Pivot it back and down to open the control door Leg is re...

Страница 11: ...ed for pictorial purposes only Screen UP BACK Side of unit is removed for pictorial purposes only 5 Remove the log box from inside the unit Lift the unit off the pallet NOTE Make sure to lift the unit up high enough to clear the upright supports the unit is sitting on PIL OT OFF L O G S Log Box 6 Reverse steps 2 4 to reinstall the screen and front of the stove CAUTION THE APPLIANCE IS VERY HEAVY T...

Страница 12: ...pply must be the same as stated on the heater s rating plate If the gas supply is different DO NOT INSTALL THE HEATER Contact your dealer for the correct model Pipe Coupling To Heater Valve Gas Supply Inlet Manual Shutoff Valve Pipe Stainless Flexible Tube Locations that the Pressure Tapping Point May Be Installed ELECTRICAL WIRING MILLIVOLT The millivolt valve is a self powered combination gas co...

Страница 13: ...ch or Remote ODS Pilot Millivolt Valve CONNECTION 1 TP TH 2 TP 3 TH Wiring Diagram Switch Spade Terminal On Off Switch ODS Pilot 3 1 2 ELECTRICAL WIRING MILLIVOLT B Thermopile Output Reading Check B Reading Thermostat contacts open Main burner off Check gas pressure to the unit If gas pressure is within minimum and maximum on data plate then check pilot voltage 325 millivolts minimum If the minimu...

Страница 14: ...t Bracket Studs Burner Ports 1 To install the back log 1 position on rear log support bracket and then press down over studs Left Bottom Log 2 Back Log 1 Top Left Log 4 Right Bottom Log 3 Right Bottom Log 3 Right Top Log 5 Rear Log Support Bracket Left Log Support Bracket Right Log Support Bracket PIL OT OFF Left Bottom Log 2 Back Log 1 Right Top Log 5 PIL OT OFF Left Bottom Log 2 Top Left Log 4 R...

Страница 15: ...t Bottom Log 3 Log 5 CAUTION DURING INITIAL OPERATION OF THE NEW HEATER BURNING LOGS WILL GIVE OFF A PAPER BURNING SMELL AND ORANGE FLAMES WILL BE PRESENT SIMPLY OPEN THE WINDOWS FOR A FEW HOURS TO VENT THE ODOR GLOWING WOOL PLACEMENT Provided with your log set is a package of Glowing Embers rock wool Break up the glowing wool into small dime sized pieces or for a finer finish use a metal wire bru...

Страница 16: ...ms or bonding agents These chemicals are not harmful but may produce annoying smoke and smells as they are burned off duringtheinitialoperationoftheappliance possibly causing headaches or eye or lung irritation This is a normal and temporary occurrence The initial break in operation should last two to three hours with the burner at the highest setting Provide maximum ventilation by opening windows...

Страница 17: ...n 5 Wait five 5 five minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information label If you don t smell gas go to the next step 6 From the OFF position turn the gas control knob counterclockwise to the IGN position Push in the control knob for 5 five second 7 With the control knob pushed in push in and release the pieso ignito...

Страница 18: ...he burner air intake holes Remove lint or particles with a vacuum brush or some pipe cleaners Failure to keep air intake holes clean will result in sooting and poor combustion The external case should be dusted and wiped with a moist cloth Annual Cleaning Inspection Refer to parts diagram for location of items Inspect and clean burner air intake holes Remove lint or particles with a vacuum brush o...

Страница 19: ...t hair spray glues etc Ventilate room Stop using odor causing products while heater is running Gas leak Locate and correct all leaks Initial burn off Ventilate room and turn unit on high until odor is gone Odor should be gone after 6 hours of continuous use Appliance shuts off during use Not enough fresh air is available for ODS pilot to operate Open window and or door for ventilation Low line pre...

Страница 20: ...eplace burner orifice Slight smoke or odor during initial operation Burner orifice is clogged or damaged Clean burner or replace burner orifice Burner is damaged Replace burner Gas regulator defective Replace gas regulator Logs appear to smoke after initial operation Vapors from paint or curing process of logs Problem will stop after a few hours of operation Run the heater with the damper open if ...

Страница 21: ... 2021 United States Stove Company 21 15 10 9 18 17 16 19 20 21 23 25 24 26 27 28 29 4 7 5 1 2 3 8 12 6 11 14 13 22 REPLACEMENT PARTS ...

Страница 22: ... 1 9 892537 7 Control Panel 1 10 892537 8 Control Cover 1 11 40854 Leg 1 12 610120 Front Screen Assy 1 13 40859 Ash Bar 1 14 40858 Control Cover 1 15 40855 Front 1 16 89921 ODS Pilot Assembly NAT 1 89922 ODS Pilot Assembly LP 1 17 81211 06 Rear Burner 1 18 81211 05 Front Burner 1 19 81211 12 VF Valve Tube 1 20 81202 Control Valve LP 1 81198 Control Valve NAT 1 21 89761 Piezo Ignitor 1 22 81212 14 ...

Страница 23: ...07 Date ______________________ Engineer Name ________________________________ License No _____________________________________ Company ______________________________________ Telephone No __________________________________ Stove Inspected Chimney Swept Items Replaced ________________________________ Service 02 Date ______________________ Engineer Name ________________________________ License No ___...

Страница 24: ...24 2021 United States Stove Company NOTES ...

Отзывы: