-5-
FLOOR PROTECTOR
The stove must be placed on solid concrete, solid masonry, or when installed on a combustible floor, on a floor
protector. The floor protector is required to provide heat, live ember, and ash protection and must be of a non-
combustible, continuous solid surface to protect against infiltration of live embers and ash. The stove must be
placed on solid concrete, solid masonry, or when installed on a combustible floor, on a Type 2 floor protector
listed to standard UL 1618 with a minimum R value of 1.03 and a minimum thickness of 1/2” or equivalent.
Dimension
Inch
mm
H*
Front
16
407
J
Flue rear
2
51
K**
Left
6
204
L**
Right
6
204
M
Flue Side
2
51
* Canadian installations require 18” (457mm)
** Canadian installations require 8” (203mm)
SPECIAL MOBILE HOME REQUIREMENTS
•
WARNING! - Do not install in a sleeping room
•
CAUTION! - The structural integrity of the
mobile home floor, wall, and ceiling/roof must be
maintained.
In addition to the previously detailed installation
requirements, mobile home installations must meet the
following requirements:
•
The heater must be permanently attached to the
floor.
1. There are two holes in the pedestal base, use
3/8” bolts through the floor.
2. To attach the leg model use two 3/8-16 UNC
bolts through the floor.
•
The heater must be electrically grounded to the
steel chassis of the mobile home with 8 GA copper
wire using a serrated or star washer to penetrate
paint or protective coating to ensure grounding.
•
When moving your mobile home, all exterior venting
must be removed while the mobile home is being
relocated. After relocation, all venting must be
reinstalled and securely fastened.
•
Outside Air is mandatory for mobile home installation.
See your dealer for purchasing.
• Check with your local building officials as other
codes may apply.
Mobile Home Attachment
Back wall / Arrière Mur
Side w
all / P
ar
oi La
tér
ale
Side w
all / P
ar
oi La
tér
ale
Back wall / Arrière Mur
Side w
all / P
ar
oi La
tér
ale
Side w
all / P
ar
oi La
tér
ale
Back w
all / A
rr
ièr
e M
ur
Ceiling / Plafond
Floor Protector / Protection de Plancher
K
H
L
J
M
M
C
B
A
E
E
D
D
F