1
INTRODUCTION AND SPECIFICATIONS
1.1
Overview
ASHIDA has designed economical & reliable Multifunction ADR241B Protection & Control
System. The simple and compact construction of ADITYA series ADR241B relay provides
integrated Protection, Control and Monitoring functions for Over head Transmission
Lines, Underground cables, and Distributed Feeders.
1.2
Features
Key Protection & Control Functions:
•
Four Independent Settings Groups.
•
Phase & Ground Over Current Function (50/51/50N/51N).
•
Two Independent Stages for Phase Over Current Protection.
•
Internally Derived / Externally measured Ground Over Current (3Io>/IE>)
Protection.
•
Inverse & Definite time Over Current Protection (IEC & IEEE/ANSI curves
according to IEC60255).
•
High Impedance Restricted Earth Fault Protection (64R).
•
Inverse & Definite time Negative Sequence Over Current Protection (46).
•
Cold Load Protection (CLP).
•
Broken Conductor Protection (46BC)
•
Under Current (low load) detection.
•
Thermal Overload function.
•
Multi shots (4-shots) Auto-reclosing function.
•
Breaker Failure detection (50BF).
•
Trip circuit supervision function (TCS).
•
Programmable Inputs & Outputs.
•
CB Close / Trip from HMI.
•
Programmable Target LEDs for indication with dual colours (8 nos.).
•
Self Supervision of relay.
•
Metering function.
•
Disturbance Recording (10 nos.).
•
Event Recording (512 nos.).
•
Fault Recording on HMI display (10nos.).
•
Non-Volatile memory.
•
Fully communicable with IEC standard open protocol IEC60870-5-103 ,
MODBUS & IEC61850.
•
Rear communication port for SCADA Communication.
Содержание ADR241B
Страница 10: ...Page intentionally Left Blank...
Страница 20: ...Page intentionally Left Blank...
Страница 34: ...Page intentionally Left Blank...
Страница 50: ...Page intentionally Left Blank...
Страница 87: ...Page intentionally Left Blank...
Страница 111: ...Page intentionally Left Blank...
Страница 112: ...ADR241B Doc ID ADR241B DO_IM_01 Ref ID ADR241B IM MS Rev No 06 Page No 112 of 272 Section 5 Metering Section...
Страница 115: ...Page intentionally Left Blank...
Страница 116: ...ADR241B Doc ID ADR241B DO_IM_01 Ref ID ADR241B IM SS Rev No 06 Page No 116 of 272 Section 6 Setting Sheet...
Страница 129: ...Page intentionally Left Blank...
Страница 130: ...Doc ID ADR241B DO_IM_01 Ref ID ADR241B IM CS Rev No 06 Page No 130 of 272 ADR241B Section 7 Communication...
Страница 145: ...Page intentionally Left Blank...
Страница 146: ...ADR241B Doc ID ADR241B DO_IM_01 Ref ID ADR241B IM UG Rev No 06 Page No 146 of 272 Section 8 User Guide...
Страница 217: ...Page intentionally Left Blank...
Страница 218: ...ADR241B Doc ID ADR241B DO_IM_01 Ref ID ADR241B IM FC Rev No 06 Page No 218 of 272 Section 9 Flow Chart...
Страница 255: ...Page intentionally Left Blank...
Страница 261: ...ADR241B Doc ID ADR241B DO_IM_01 Ref ID ADR241B IM DR Rev No 06 Page No 261 of 272 Event Record...
Страница 262: ...Page intentionally Left Blank...
Страница 263: ...Doc ID ADR241B DO_IM_01 Ref ID ADR241B IM TC Rev No 06 Page No 263 of 272 ADR241B Section 11 Testing and Commissioning...