automatically shut off. When a handpiece

is removed from it's holder, pressure is

automatically opened and ready for use

with foot control.
The amount of air pressure supplied to

each handpiece may be adjusted by

turning the flow control for that handpiece

on the control block (See page 8).

3. WET/DRY FOOT CONTROL 

(Fig. 8) - The

foot control activates the handpieces and

water coolant spray.
Position the foot control on the floor. For

handpiece operation, apply foot pressure

to any part of the center disk. The

handpiece must be removed from its

holder before operation can begin.

OPERATION FUNCTIONS:

1. THREE-WAY AIR/WATER SYRINGE 

-

Depress the right button for air operation,

and the left button for water operation.

Depressing both buttons will create a mist.

The syringe features quick-change

autoclavable tips: To remove a tip, press

on the locking collar surrounding the tip

socket and pull the used tip straight out of

the socket (see Fig. 6). To insert a new tip,

press locking collar and push tip into

socket as far as it will go. Release collar

and gently tug on tip before using to

ensure that tip is securely locked into

socket.

Syringe Tip Sterilization:

1)

Remove contaminated syringe tip.

2)

Remove all visible signs of contamination

before autoclaving.

3)

Autoclave tip at 132° C (270° F) for ten

minutes.

4)

Sterilize between each patient use.

NOTE

: Since only the tips can be

autoclaved, it is recommended that the

air/water syringe be bagged with a

disposable, single-use plastic sleeve

between each patient use.

2. HANDPIECE CONTROLS 

(Fig. 7) - The

Aseptico ADU-25 includes two handpieces

mounted to the front bar. These are fully

automatic. By placing a handpiece into its

proper holder, the pressure is

APPLY

PRESSURE TO

ACTIVATE

HANDPIECE

WATER

OFF

WATER

ON

Figure 8 - Foot Control

Figure 7 

LOWSPEED

CONTROL

HIGHSPEED CONTROL

3-WAY

AIR/WATER

SYRINGE

Figure 6

DEPRESS

LOCKING COLLAR

Содержание ADU-25

Страница 1: ...OPERATION and MAINTENANCE INSTRUCTION MANUAL ADU 25 Custom Cart...

Страница 2: ...7 Handpiece Controls 4 Fig 8 Foot Control 4 Fig 9 Water Tank Removal 5 Fig 10 Right Side of Chassis 6 Fig 11 AA 21 HVE Vacuum Sys Opt 6 Fig 12 AA 25 LVE Vacuum Sys Opt 7 Fig 13 AA 290CK Central Vac K...

Страница 3: ...ions provided in this manual to receive the best and longest service from your Aseptico equipment Separate manuals may be provided to cover the operation and maintenance of hand held pieces or other a...

Страница 4: ...E VACUUM SYSTEM Optional THREE WAY SYRINGE NWS 8 HDPE WATER SUPPLY TANK Optional HIGHSPEED HANDPIECE CONTROL AA 25 SALIVA EJECTOR SYSTEM Optional REMOVABLE INSTRUMENT TRAY 3 The ADU 25 unit must be co...

Страница 5: ...connect at the rear of the delivery head Fig 4a Note manual release lever on disconnect Insert metal fitting on top of bottle into quick disconnect Locking ring will snap into place Press release leve...

Страница 6: ...e locking collar surrounding the tip socket and pull the used tip straight out of the socket see Fig 6 To insert a new tip press locking collar and push tip into socket as far as it will go Release co...

Страница 7: ...ol 7 FLUSH TOGGLE Fig 10 The flush toggle located on the right side of the chassis allows you to quickly and completely flush your handpieces washing away contaminants which may have accumulated in th...

Страница 8: ...The ADU 25 is supplied with a large capacity container 9 AA 25 SALIVA EJECTOR SYSTEM Optional The AA 25 Saliva Ejector is an air powered self contained oral evacuation system It is supplied with a pla...

Страница 9: ...clean water or vacuum system cleanser through the evacuator hose and thoroughly cleaning the waste bottle CAUTION Use only NON foaming cleansers in the vaccum lines 10 AA 290CK CENTRAL VACUUM KIT Opti...

Страница 10: ...erclockwise will increase pressure 3 HANDPIECE PRESSURE ADJUSTMENT Fig 15 The amount of air pressure supplied to each handpiece may be adjusted by turning the flow control for that handpiece on the co...

Страница 11: ...onds after every patient and about 20 seconds at the beginning of each day Refer to page 4 3 GENERAL CLEANING The cart exterior is designed to make cleaning and the use of prophylactic barriers as eas...

Страница 12: ...rt or whole Aseptico shall be the sole arbiter of such action In the event of alleged defect under warranty the purchaser is to notify Aseptico s Customer Service Department promptly Customer Service...

Отзывы: