AC90SVHE-3 / AC100SVHE-3 Operations Manual....
48
KW-HOUR METER
kW-Hours:XXXXXXX.XX Run Time. XX:XX:XX:XX
Max. Level: XXX.X% Max. Power: XX.XXkW
Clear Exit
7.7
kW-HOUR METER AND MAXIMUM POWER LEVEL DISPLAY
Press the SHORE POWER + CONVERTER POWER buttons to access the Automatic
KW-HOUR METER and maximum power level display.
Press the Clear
(F1)
button to clear all data and the Exit
(F5)
button to exit.
Application: this reference kW-hour meter can be used to check the billing received in a marina.
Immediately after connecting shore power and turning the converter's red disconnect switch, clear
the data in this screen. When ready to leave, take down the kW-hours and run time before
disconnecting the shore power. Additionally, this screen can be used to diagnose converter
shutdowns. Since the Max. Level and Max. Power data are updated with slow-response metering
(approximately 1 second), only average use data are represented. Instantaneous motor-start
surges and such will not be represented by the data. If the Max. Level exceeds 110%, and a
shutdown of the Shore Power has occurred, it is very likely the average loading is exceeding the
converter's capacity. The Max. Power is provided since Max. Level is affected by Shore Cord
Setup settings.