115
9. TROUBLESHOOTING
When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply
before proceeding with the following troubleshooting procedures.
The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which
are not listed occur, contact your nearest local dealer. DO NOT attempt to troubleshoot the unit by yourself.
No
Fault conditions
Possible causes / corrective actions
1
The air conditioner unit will not resume after
power failure.
•
The auto restart function is not functioning. Please
turn on the unit with the wireless / wired controller.
2
The compressor does not operate 3 minutes
after the air conditioner unit is started.
•
Protection against frequent starting.
•
Wait for 3 or 4 minutes for the compressor to start
operating by it self.
3
The airflow is too slow or room cannot be
cooled sufficiently.
•
The air filter is dirty.
•
The doors and windows are opened.
•
The air suction and discharge of both indoor and
outdoor units are clogged or blocked.
•
The regulated temperature or temperature setting
is not low enough.
4
Discharge airflow has bad odor.
•
Cigarettes, smoke particles, perfume and others,
which might have adhered onto the coil, may
cause odor.
•
Contact your nearest dealer.
5
Condensation on the front air grille of the indoor
unit.
•
This is caused by air humidity after an extended
period of operation.
•
The set temperature is too low. Increase the
temperature setting and operate the unit at high
fan speed.
6
Water flowing out from the air conditioner.
•
Switch off the unit and contact your nearest
dealer. This might be due to tilted installation.
7
Hissing airflow sound from the air conditioner
unit during operation.
•
Liquid refrigerant flowing into the evaporator coil.
8
The wireless controller display is dim.
•
The batteries are discharged.
•
The batteries are not correctly inserted.
•
The assembly is not good.
9
Compressor operates continuously.
•
Dirty air filter. Clean the air filter.
•
Temperature setting too low (cooling). Use higher
temperature setting.
•
Temperature setting too high (heating), Use lower
temperature setting.
10
No cool air comes out during cooling cycle, or
no hot air comes out during heating cycle.
•
Temperature setting too high (cooling). Use lower
temperature setting.
•
Temperature setting too low (heating). Use higher
temperature setting.
11
On heating cycle, warm air does not come out.
•
Unit is in defrost mode. Heating operation will
resume after defrost cycle ends.
Содержание A5LCX 10 C
Страница 1: ...DC Inverter Single Split A5LCX 2007 Models A5LCX 10 C CR A5LCX 15 C CR A5LCX 20 C CR A5LCX 25 C CR...
Страница 14: ...12 MODEL A5CKX20A A5LCX20C A5CKX25A A5LCX25C A5CKX20C A5LCX25C MODEL A5CKX10C A5LCX10C A5CKX15C A5LCX15C...
Страница 15: ...13 MODEL A5CMX20E A5LCX20C A5CMX25E A5LCX25C MODEL A5CMX20ER A5LCX20CR ACMX25ER A5LCX25CR...
Страница 16: ...14 MODEL A5CCX20C A5LCX20C A5CCX25C A5LCX25C MODEL A5CCX10C A5LCX10C A5CCX15C A5LCX15C...
Страница 17: ...15 MODEL A5CCX20CR A5LCX20CR A5CCX25CR A5LCX25CR MODEL A5CCX10CR A5LCX10CR A5CCX15CR A5LCX15CR...
Страница 20: ...18 Installation Installation Diagram...
Страница 108: ...106 7 WIRING DIAGRAMS Indoor Unit MODEL A5WMX 10 15 G GR WITH IONIZER Outdoor Unit MODEL A5LCX 10 15 C CR...
Страница 109: ...107 Indoor Unit MODEL A5WMX 20 25 G GR WITH IONIZER Outdoor Unit MODEL A5LCX 20 25 C CR...
Страница 110: ...108 MODEL A5CKX 10 15C CR c w A5LCX 10 15 C CR...
Страница 111: ...109 MODEL A5CKX 20C CR c w A5LCX 20C CR...
Страница 112: ...110 MODEL A5CKX 20 25A AR c w A5LCX 20 25C CR...
Страница 113: ...111 MODEL A5CMX 20 25E ER c w A5LCX 20 25C CR...
Страница 114: ...112 MODEL A5CCX 10 15C CR c w A5LCX 10 15C CR...
Страница 115: ...113 MODEL A5CCX 20 25C CR c w A5LCX 20 25C CR...
Страница 127: ...125 MODEL A5CKX 20 25A AR...
Страница 129: ...127 MODEL A5CKX 10 15 20C CR...
Страница 131: ...129 MODEL A5CMX 15 20 25E ER...