9
2. FEATURES
Energy Saving
Total energy saved can be as high as 30% compared to the conventionally controlled units.
Efficient
Acson DC Inverter series achieve excellent efficient with high EER & COP rating.
Comfortable
Users enjoy better comfort and quietness with inverter technology. When the environmental factors, such as
temperature, humidity, airflow and/or outside ambient conditions, are obtained and processed through a con-
trol algorithm, the compressor motor speed can be varied to optimize the cooling power to create a more
precisely controlled room temperature (i.e. less temperature fluctuation).
R410A Refrigerant (New)
Introducing the new type of refrigerant - R410A which is environmental friendly with Zero Ozone Depletion
Potential (ODP = 0). R410A also provides the higher volumetric capacity and better refrigerating effect per unit
of volume.
Advance Technology
The traditional conventional air conditioners repeat "the start" and "the stop" during the thermostat cycle off and
causes the room temperature to be unstable. Incorporating fuzzy logic control into the ACSON Inverter design
enables greater flexibility in handling the system control.
This result in:
- Powerful, efficient and economical operation.
- Even room temperature control.
- Constant and quiet compressor operation.
- Enhanced system reliability and reduced maintenance costs.
Self Diagnostic
Both indoor and outdoor LED Error Code Indicator helps to simplify the trouble shooting process. Where there's
fault detected during operation, the defect code will be to indicate the faults.
Wireless Remote Control
- The compact LCD transmitter is able to operate the air conditioner unit within the distance of 9 meters.
- Fan motor speed can be set at low / medium / high or automatic.
- Sleep mode automatically increase set temperature since room temperature is lower at night thus
achieving comfort surrounding.
- Airflow direction can be controlled automatically.
- Room temperature is controlled by electronic thermostat.
- The unit can be preset to on and off automatically for maximum of 15 hours by using timer on/off.
- Introducing turbo mode, which allows inverter compressor operates at high power and maximum
speed to achieve required temperature quickly.
Содержание A5LCX 10 C
Страница 1: ...DC Inverter Single Split A5LCX 2007 Models A5LCX 10 C CR A5LCX 15 C CR A5LCX 20 C CR A5LCX 25 C CR...
Страница 14: ...12 MODEL A5CKX20A A5LCX20C A5CKX25A A5LCX25C A5CKX20C A5LCX25C MODEL A5CKX10C A5LCX10C A5CKX15C A5LCX15C...
Страница 15: ...13 MODEL A5CMX20E A5LCX20C A5CMX25E A5LCX25C MODEL A5CMX20ER A5LCX20CR ACMX25ER A5LCX25CR...
Страница 16: ...14 MODEL A5CCX20C A5LCX20C A5CCX25C A5LCX25C MODEL A5CCX10C A5LCX10C A5CCX15C A5LCX15C...
Страница 17: ...15 MODEL A5CCX20CR A5LCX20CR A5CCX25CR A5LCX25CR MODEL A5CCX10CR A5LCX10CR A5CCX15CR A5LCX15CR...
Страница 20: ...18 Installation Installation Diagram...
Страница 108: ...106 7 WIRING DIAGRAMS Indoor Unit MODEL A5WMX 10 15 G GR WITH IONIZER Outdoor Unit MODEL A5LCX 10 15 C CR...
Страница 109: ...107 Indoor Unit MODEL A5WMX 20 25 G GR WITH IONIZER Outdoor Unit MODEL A5LCX 20 25 C CR...
Страница 110: ...108 MODEL A5CKX 10 15C CR c w A5LCX 10 15 C CR...
Страница 111: ...109 MODEL A5CKX 20C CR c w A5LCX 20C CR...
Страница 112: ...110 MODEL A5CKX 20 25A AR c w A5LCX 20 25C CR...
Страница 113: ...111 MODEL A5CMX 20 25E ER c w A5LCX 20 25C CR...
Страница 114: ...112 MODEL A5CCX 10 15C CR c w A5LCX 10 15C CR...
Страница 115: ...113 MODEL A5CCX 20 25C CR c w A5LCX 20 25C CR...
Страница 127: ...125 MODEL A5CKX 20 25A AR...
Страница 129: ...127 MODEL A5CKX 10 15 20C CR...
Страница 131: ...129 MODEL A5CMX 15 20 25E ER...