- OPERATING INSTRUCTIONS - Vr. Mondial Group - 10/10 -  ISTR-MY39EENGmondial -  PAG. 13

 

Display resolution: 1 ° or 0,1° 
Overall accuracy: +/- (0,5 % fs + 1 digit) 
Sampling rate: 130 ms. 
Display: 3 Digit  Red (Blue optional) h 15,5 mm 
Software class and structure : Class A 
Compliance:  ECC  directive  EMC 2004/108/CE (EN55022: class B; 
EN61000-4-2: 8KV air, 4KV cont.; EN61000-4-3: 10V/m; EN61000-
4-4:  2KV  supply,  inputs,  outputs;  EN61000-4-5:  supply  2KV  com. 
mode,  1  KV\  diff.  mode;  EN61000-4-6:  3V),    LV  2006/95/CE  (EN 
60730-1, EN 60730-2-7, EN 60730-2-9) 
Directive  37/2005/CE  (EN13485  air,  S,  A,  2,-  50°C  +90°C  with 
probe NTC 103AT11) 

 
7.5 - INSTRUMENT ORDERING CODE

 

 
Y39E 

(instrument with mechanical keyboard

 

)

 

Y39SE 

(instrument with Sensitive Touch keyboard

 

)

 

 
a b c d e f g h i j

 

kk

 

ll 

 

a : POWER SUPPLY

 

H

 =  Supply 100..240 VAC

 

G

 = Supply 12..24 VAC/VDC

 

F

 = Supply 12 VAC/VDC 

 

b : OUT1 
R

 = Out1 Relay SPST-NO 16A-AC1 

 

c : OUT2

 

R

 = Out2 Relay SPDT 8A-AC1 

-

 = (No) 

 

d : OUT3

 

R

 = Out3 Relay SPST-NO 5A-AC1 

-

 = (No) 

 

e: BUZZER

 

B

 = Buzzer 

-

 = (No) 

 

f : TERMINAL BLOCK

 

-

 = (Standard)

 

E

 = Extractable 

 

g : DISPLAY

 

-

 = Red 

= Blue 

 

h, i, j : INTERNAL CODES 
kk, ll : SPECIAL CODES

 

Содержание Y39E

Страница 1: ...tiefk hlschr nke ALLGEMEINE GEBRAUCHSANWEISUNGEN Cod 26 23 073 Rev 6 Ihr Nordcap Fachh ndler K lte Berlin Am Pfarracker 41 12209 Berlin Fon 49 30 74 10 40 22 Fax 49 30 74 10 40 21 Mail info kaelte be...

Страница 2: ...ANICAL MOUNTING 3 3 ELECTRICAL CONNECTIONS 3 4 ELECTRICAL WIRING DIAGRAM 4 FUNCTIONS 4 1 ON STAND BY FUNCTION 4 2 NORMAL MODE AND ECONOMIC MODE 4 3 MEASURING AND VISUALIZATION 4 4 DIGITAL INPUT 4 5 OU...

Страница 3: ...Indicates AUX output status on on off off or inhibited flashing 12 Led Stand By Indicate the Stand by status 2 PROGRAMMING 2 1 FAST PROGRAMMING OF SET POINT Press the key P then release it and the di...

Страница 4: ...any key for the time t Lo the instrument automatically disable the normal functions of the keys When the keyboard is lock if any of the key is pushed on the display will appear Ln to indicate the act...

Страница 5: ...input configured as i Fi 1 2 or 3 If i Et oF the selection mode Eco Norm through the digital input is disabled The economic mode activated is indicated by the label Eco If i dS Ec the display in econ...

Страница 6: ...o3 The outputs can be configured for the following functions ot to control the compressor or however the temperature control device dF to control the defrosting device Fn to control the fans Au to co...

Страница 7: ...ble to prevent activation of the output after the instrument is turned on for the time set in the parameter P od During the power on delay phase the display shows the indication od alternating with th...

Страница 8: ...s interrupted If the temperature measured by the probe is higher than the temperature set in the parameter d tE the defrosting is inhibited The active defrost is shown on the instrument display with t...

Страница 9: ...but with an inverse function output activated in normal condition and disabled in alarm status L when one wants the function described as AL but with inverse logic output activated in normal conditio...

Страница 10: ...eters To use the device A01 it s necessary that the device or instrument are being supplied SUPPLY USB SUPPLY ADAPTER 12 VDC AC SUPPLY USB For additional info please have a look at the A01 instruction...

Страница 11: ...mode H Heating C Cooling nr Neutral Zone H C nr C d parameters relative to defrosting control 21 d dt Defrosting Type EL Electrical heating stop compr in hot gas reverse cycle EL in EL 22 d di Defros...

Страница 12: ...AL t L on HE dF 52 o o3 OUT3 function see o o1 oF ot dF Fn Au At AL t L on HE Fn 53 o bu Buzzer function mode oF disable oF 1 2 3 3 1 active alarms only 2 key pressed only 3 active alarms and key pres...

Страница 13: ...up to 3 relay outputs OUT1 SPST NO 16A AC1 6A AC3 1HP 250VAC 1 2HP 125 VAC OUT2 SPDT 8A AC1 3A AC3 1 2HP 250VAC 1 3HP 125 VAC OUT3 SPST NO 5A AC1 2A AC3 250 VAC 1 8HP 125 250VAC 16 A Max for common pi...

Страница 14: ...2KV com mode 1 KV diff mode EN61000 4 6 3V LV 2006 95 CE EN 60730 1 EN 60730 2 7 EN 60730 2 9 Directive 37 2005 CE EN13485 air S A 2 50 C 90 C with probe NTC 103AT11 7 5 INSTRUMENT ORDERING CODE Y39E...

Страница 15: ...iegend transportiert worden sollte es erst nach 24 Stunden in Betrieb genommen werden damit das Oel wieder in den Kompressor zur ckfliessen kann Der Schrank muss ber das beiliegende Netzkabel an eine...

Страница 16: ...ng flexibel F r diese Arbeit keine spitzen oder scharfe Gegenst nde benutzen welche die T rdichtung besch digen k nnten Achtung Folgende Arbeit muss von einem Servicetechniker ausgef hrt werden Schalt...

Страница 17: ...schrauben IST DAS SPEISEKABEL BESCH DIGT MUSS DIESES VOM HERSTELLER BZW SEINEM KUNDENDIENST ODER AUF JEDEM FALL VON EINER QUALIFIZIERTEN PERSON ERSETZT WERDEN UM RISIKEN ZU VERMEIDEN 7 L N G E R E Z E...

Отзывы: