– OPERATING INSTRUCTIONS – MX33HENG00 - PAGE 14

 

command 
 
15  =  Stop  work  cycle 
command 

77 

diF2

  Function  and  operating 

logic  of  digital  input  2 
(alternative to Pr2): 
see “diF1” 

15...-15 

 

78 

diF3

  Function  and  operating 

logic  of  digital  input  2 
(alternative to Pr3): 
see “diF1” 

15...-15 

 

79 

did1

  Delay of digital input 1 

OFF ÷ 99.59 

min.sec 

OFF   

80 

did2

  Delay of digital input 2 

OFF ÷ 99.59 

min.sec 

OFF   

81 

did3

  Delay of digital input 3 

OFF ÷ 99.59 

min.sec 

OFF   

]AuS group 

(parameters relating to the auxiliary output) 

Par.

 

Description

 

Range

 

Def.

 

Note

 

82 

FOA

  Operating 

mode 

of 

auxiliary output 
0= No Function 
1= CooL output delayed 
(depending 

on 

compressor)   
2= Manual activation by 
key or digital input 

0 / 1 / 2 

 

83 

tuA

  Time relating to 

auxiliary output 1 

OFF ÷ 99.59 

min.sec 

OFF   

]Out    group 

(parameters  relating  to  the  configuration  of  the 

outputs) 

Par.

 

Description

 

Range

 

Def.

 

Note

 

84 

Out1

  Configuration 

of 

operation 

of 

OUT1 

output: 
OFF= No Function 
CooL= Cold control 
HEAt = Hot control 
rh = Humidifier 
drh = Dehumidifier 
dEF= Defroster 
FAnr = Cell fan 
FAnE  =  Extractor/air 
exchange fan 
drhE  =  Dehumidifier  + 
extractor/air exchange 
LIGH = Light 
AuS = Auxiliary 
ALt = Silenceable alarm  
AL  =  Non-silenceable 
alarm 
ALL = Memorized alarm  
On = Active in ON state 
End  =  Signalling  of  end 
of cycle 

OFF/ CooL/ 

HEAt/ rh / 

drh / dEF / 

FAnr / FAnE 

/ drhE / LIGH 

/ AuS / ALt / 

AL / ALL / -
ALt / -AL / -

ALL / On / 

End 

CooL   

85 

Out2

  Configuration 

of 

operation 

of 

OUT2 

output: 
see “Out1” 

OFF/ CooL/ 

HEAt/ rh / 

drh / dEF / 

FAnr / FAnE 

/ drhE / LIGH 

/ AuS / ALt / 

AL / ALL / -
ALt / -AL / -

ALL / On / 

End 

HEAt   

86 

Out3

  Configuration 

of 

operation 

of 

OUT3 

output: see “Out1” 

OFF/ CooL/ 

HEAt/ rh / 

drh / dEF / 

FAnr / FAnE 

/ drhE / LIGH 

/ AuS / ALt / 

rH 

 

87 

Out4

  Configuration 

of 

operation 

of 

OUT4 

output: see “Out1” 

OFF/ CooL/ 

HEAt/ rh / 

drh / dEF / 

FAnr / FAnE 

/ drhE / LIGH 

/ AuS / ALt / 

AL / ALL / -
ALt / -AL / -

ALL / On / 

End 

drh   

88 

buF

  Configuration 

of 

operation of buzzer 

yES / no 

yES   

]PAn  group 

(parameters  relating  to  the  configuration  of  the 

keypad) 

Par.

 

Description

 

Range

 

Def.

 

Note

 

89 

USrb

  Operating  mode  of  U 

key: 
OFF= No Function 
1= Light command 
2= 

Auxiliary 

output 

command 
3= Defrosting command 
4=  Switch  on/Switch  off 
(Stand-by) 
5=  Air  recycling  cycle 
command 
6=  Work  Cycle  with 
START/STOP 

mode 

command 
6=  Work  Cycle  with 
START/PAUSE-STOP 
mode command 

OFF / 1 / 2 / 

3 / 4 / 5 / 6 

OFF   

90 

Fbu

  Operating 

mode 

of 

UP/F1 key: see “USrb” 

OFF / 1 / 2 / 

3 / 4 / 5 / 6 

OFF   

91 

Fbd

  Operating 

mode 

of 

DOWN/F2 

key: 

see 

“USrb” 

OFF / 1 / 2 / 

3 / 4 / 5 / 6 

OFF   

92 

PASS

  Password  for  access  to 

the 

operating 

parameters  

OFF ÷ 9999  OFF   

]PrG group 

(Parameters relating to the work cycles) 

Par.

 

Description

 

Range

 

Def.

 

Note

 

93 

SPt1

  Step  1  temperature  Set 

Point  

OFF/SPLt ÷ 

SPHt 

0.0   

94 

SPh1

  Step  1  humidity  Set 

Point  

OFF/SPLh ÷ 

SPHh 

0.0   

95 

tS1

  Step 1 duration time 

OFF ÷ 99.59 

hrs.min 

OFF   

96 

SPt2

  Step  2  temperature  Set 

Point  

OFF/SPLt ÷ 

SPHt 

0.0   

97 

SPh2

  Step  2  humidity  Set 

Point 

OFF/SPLh ÷ 

SPHh 

0.0   

98 

tS2

  Step 2 duration time 

OFF ÷ 99.59 

hrs.min 

OFF   

99 

SPt3

  Step  3  temperature  Set 

Point  

OFF/SPLt ÷ 

SPHt 

0.0   

100 

SPh3

  Step  3  humidity  Set 

Point  

OFF/SPLh ÷ 

SPHh 

0.0   

101 

tS3

  Step 3 duration time 

OFF ÷ 99.59 

hrs.min 

OFF   

102 

ECS

  Behaviour  at  end  of 

cycles: 
1=  Returns  to  normal 
regulation  (without  any 
signalling) 
2=  Returns  to  normal 
signalling 

“End” 

and 

activating the buzzer for 

1 / 2 / 3 / 4 / 

5 / 6 / 7 / 8 

1  

 

Содержание X33H

Страница 1: ...PARAMETER PROGRAMMING 2 5 CONFIGURATION OF THE PARAMETERS WITH A01 2 6 KEYPAD LOCK 3 WARNINGS FOR INSTALLATION AND USE 3 1 PERMITTED USE 3 2 MECHANICAL INSTALLATION 3 3 ELECTRICAL CONNECTIONS 3 4 ELE...

Страница 2: ...n the value set will be memorized and the display will then move on to read SP h humidity Set point and the value set for it To modify this value use the UP and DOWN keys The SP h Set point can be set...

Страница 3: ...ted with a 5 pole connector The A01 device can be used for the serial programming of appliances that must have the same configuration of the parameters or for keeping a copy of the programming of one...

Страница 4: ...upply the appliance can be in one of 2 different states ON means that the controller actuates the control functions STAND BY means that the controller does not actuate any function and the display is...

Страница 5: ...sabled The buF par allows the buzzer to be enabled YES or disabled no 4 4 TEMPERATURE REGULATOR All the parameters regarding the regulation of the temperature are contained in the rEG group The regula...

Страница 6: ...he appliance is switched on for the time set in the od par During the phase of delay upon switching on the display will show the indication od alternating with the normal programmed messages The delay...

Страница 7: ...hether the recycling fans must be switched on FdF On or whether they should switch off during defrosting FdF OFF In this last case it is possible to delay the re starting of the fans even after the en...

Страница 8: ...he alarm conditions of the appliance are Errors in Sensors E1 E1 E2 E2 E3 E3 E4 E4 Temperature alarms HI 1 LO 1 HI 2 LO 2 HI 3 LO 3 HI 4 LO 4 External alarm AL Door open alarm AdoP 4 13 1 TEMPERATURE...

Страница 9: ...upon the closure of the input and after the did time the alarm is activated and the appliance alternately shows on the upper display AL and the variable established in the diSU par 2 Signalling of an...

Страница 10: ...cle the cycle is interrupted and the appliance returns to the normal regulation state STOP 7 START PAUSE STOP mode When the command is given by key the cycle is started START If the key is pressed for...

Страница 11: ...the event that it is envisaged that the operator cannot be present at the end of this phase and thus cannot extract the product it is possible to program a third maintenance phase For this third phase...

Страница 12: ...temp Pr3 Measurement of OFF Pr1 Pr2 Pr3 Pr4 SPt SPh Pr4 Pr3 sensor auxiliary temp Pr4 Measurement of Pr4 sensor humidity SPt Active temperature Set Point SPh Active humidity Set Point rEG group param...

Страница 13: ...shold for high Pr3 temperature OFF 58 0 302 0 C F OFF 62 LAL3 Alarm threshold for low Pr3 temperature OFF 58 0 302 0 C F OFF 63 dAL3 Differential of Pr3 temperature alarms 0 0 30 0 C F 2 0 64 ALd3 Del...

Страница 14: ...t AL ALL On End HEAt 86 Out3 Configuration of operation of OUT3 output see Out1 OFF CooL HEAt rh drh dEF FAnr FAnE drhE LIGH AuS ALt rH 87 Out4 Configuration of operation of OUT4 output see Out1 OFF C...

Страница 15: ...encountered within 12 months of delivery The guarantee is limited to the repair or replacement of the product Any opening of the housing tampering with the appliance or non compliant use and installa...

Страница 16: ...measurement sampling 130 ms Display 4 digit 1 Red and 1 Amber yellow h 7 mm Class and structure of the software Class A Conformity Directives 2004 108 CE EN55022 class B EN61000 4 2 8KV air 4KV cont E...

Отзывы: