Ascon tecnologic TLI40 Скачать руководство пользователя страница 12

ASCON TECNOLOGIC - TLI 40 - OPERATING INSTRUCTIONS - 

PAG. 12

tc K  

“HCFG” = tc 

“SEnS” = CrAl 

-270 ... 1370 °C

- 454 ... 2498 °F

-199.9 ... 999.9 °C

-199.9 ... 999.9 °F

tc S 

“HCFG” = tc 

“SEnS” = S 

-50 ... 1760 °C

-58 ... 3200 °F

-50.0 ... 999.9 °C

-58.0 ... 999.9 °F

tc B 

“HCFG” = tc 

“SEnS” = b 

72 ... 1820 °C 

162 ... 3308 °F

 

72.0 ... 999.9 °C 

162.0 ... 999.9 °F

 

tc E 

“HCFG” = tc 

“SEnS” = E 

-150 ... 750 °C

-252 ... 1382 °F

-150.0 ... 999.9 °C

-199.9 ... 999.9 °F

tc L 

“HCFG” = tc 

“SEnS” = L 

-150 ... 900 °C

-252 ... 1652 °F

-150.0 ... 900.0 °C

-199.9 ... 999.9 °F

tc N 

“HCFG” = tc 

“SEnS” = n 

-270 ... 1300 °C

-454 ... 2372 °F

-199.9 ... 999.9 °C

-199.9 ... 999.9 °F

tc R 

“HCFG” = tc 

“SEnS” = r 

-50 ... 1760 °C

-58 ... 3200 °F

-50.0 ... 999.9 °C

-58.0 ... 999.9 °F

tc T 

“HCFG” = tc 

“SEnS” = t 

-270 ... 400 °C

-454 ... 752 °F

-199.9 ... 400.0 °C

-199.9 ... 752.0 °F

tc C 

“HCFG” = tc 

“SEnS” = C 

0 ... 2320 °C 

32 ... 4208 °F

 

0.0 ... 999.9 °C 

32.0 ... 999.9 °F

 

TECNOLOGIC IRS 

range “A” 

“HCFG” = tc 

“SEnS”= Ir.J - Ir.CA 

-46 ... 785 °C

-50 ... 1445 °F

-46.0 ... 785.0 °C

-50.8 ... 999.9 °F

Pt100 (IEC) 

“HCFG” = rtd 
“SEnS” = Pt1 

-200 ... 850 °C

-328 ... 1562 °F

-99.9 ... 850.0 °C

-99.9 ... 999.9 °F

PTC (KTY81-121) 

“HCFG” = rtd 
“SEnS” = Ptc 

-55 ... 150 °C

-67 ... 302 °F

-55.0 ... 150.0 °C

-67.0 ...302.0 °F

NTC (103-AT2) 

“HCFG” = rtd 
“SEnS” = ntc 

-50 ... 110 °C

-58 ... 230 °F

-50.0 ... 110.0 °C

-58.0 ... 230.0 °F

0..20 mA 

“HCFG” = I 

“SEnS” = 0.20 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

 

4..20 mA 

“HCFG” = I 

“SEnS” = 4.20 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

0 ... 50 mV  

“HCFG” = UoLt 

“SEnS” = 0.50 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

0 ... 60 mV 

“HCFG” = UoLt 

“SEnS” = 0.60 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

12 ... 60 mV 

“HCFG” = UoLt 
“SEnS” = 12.60 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

0 ... 5 V 

“HCFG” = UoLt 

“SEnS” = 0.5 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

1 ... 5 V 

“HCFG” = UoLt 

“SEnS” = 1.5 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

0 ... 10 V 

“HCFG” = UoLt 

“SEnS” = 0.10 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

2 ... 10 V 

“HCFG” = UoLt 

“SEnS” = 2.10 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

Potentiometer 

(> 1 K

“HCFG” = UoLt 

“SEnS” = Pot 

-1999 ... 9999

-199.9 ... 999.9
-19.99 ... 99.99

-1.999 ... 9.999

7.6 - INSTRUMENT ORDERING CODE

 

TLI 40  a b c d e f g h ii

 

a : POWER SUPPLY

 

= 24 VAC/VDC 

= 100 ... 240 VAC

 

b : OUTPUT OUT1

 

-

= None

= Relay

= Voltage VDC for SSR

= Analogue 0/4 ..20 mA

= Analogue 0/2 .. 10 V

c : OUTPUT OUT2
-

= None

= Relay

= Voltage VDC for SSR

d : OUTPUT OUT3
-

= None

= Relay

= Voltage VDC for SSR

e : OUTPUT OUT4
-

= None

= Relay

= Voltage VDC for SSR

f : COMMUNICATION INTERFACE

= RS 485 Serial interface

= RS 485 Serial Int digital input

-

= No interface

g : SENSORS OUTPUT SUPPLY
A

 = 12 VDC

B

 = 2,5 VDC (Potentiometer input)

h : OPTIONAL PROBES

- = None

ii = SPECIAL CODES

Note : 

- The output OUT4 must be the same type as OUT3.
- The digital input can only be present as an alternative to the output
OUT4.

TLI 40 PASSWORD = 381

Содержание TLI40

Страница 1: ...6 PROBLEMS MAINTENANCE AND GUARANTEE 6 1 ERROR SIGNALLING 6 2 CLEANING 6 3 GUARANTEE AND REPAIRS 7 TECHNICAL DATA 7 1 ELECTRICAL DATA 7 2 MECHANICAL DATA 7 3 MECHANICAL DIMENSIONS PANEL CUT OUT AND MO...

Страница 2: ...value has been programmed push key P once more the new value will be memorised and the display will show only the code of the selected parameter By using the UP or DOWN keys it is then possible to se...

Страница 3: ...ked as instrument disconnecting device which interrupts the power supply to the equipment It is also recommended that all the electrical circuits connected to the instrument must be protect properly u...

Страница 4: ...ument is switched on by using the U key that has been suitably programmed see par U key with function USrb r Pic or through the suitably programmed digital input see par digital input with function dI...

Страница 5: ...d in sec and the alarm will be activated only after the elapsing of that time ALARM LATCH the alarm output may behave in two different ways depending on the value added to par Abn 0 ALARM NOT LATCHED...

Страница 6: ...eter input it is possible to set the zero value with this function By closing the contact connected to the digital input assuming the value measured in that instant as 0 r P0P For the instruments equi...

Страница 7: ...tput 3 Par Description Range Def Note 20 O3F Functioning of output 3 ALno ALnc Ser OFF ALno Group O4 parameters relative to output 4 Par Description Range Def Note 21 O4F Functioning of output 4 ALno...

Страница 8: ...to a high value when the material to be measured is particularly light reflective and reduce it when the surface is especially dark non reflective keeping in mind however that for most materials the r...

Страница 9: ...ARM The alarm is activated when the process value goes below the alarm threshold set on parameter AL1L or goes higher than alarm set on parameter AL1H Ab1 ALARM AL1 FUNCTION This permits definition of...

Страница 10: ...r the instruments equipped with potentiometer input with this function it is possible to set the points of measure of the potentiometer by means of an auto ranging procedure through which the paramete...

Страница 11: ...ection class against electric shock Class II for Front panel Insulation Reinforced insulation between the low voltage section supply and relay outputs and the front panel Reinforced insulation between...

Страница 12: ...99 99 99 1 999 9 999 0 50 mV HCFG UoLt SEnS 0 50 1999 9999 199 9 999 9 19 99 99 99 1 999 9 999 0 60 mV HCFG UoLt SEnS 0 60 1999 9999 199 9 999 9 19 99 99 99 1 999 9 999 12 60 mV HCFG UoLt SEnS 12 60...

Отзывы: